e- Ab Sensor-based Real-time Detection of Oncogenic Human Papilloma Viruses
Nano-mechanical and Nano-electrosensing Devices Based Interaction Force and Interaction Kinetics Analysis of Oncogenic Human Papilloma Viruses
調査の概要
詳細な説明
Human papillomavirus (HPV)-induced cervical carcinogenesis is proposed to be multi-step in nature. The major steps in cervical carcinogenesis include persistent infection of the metaplastic cervical epithelium with one or more of the oncogenic HPV infection, clonal progression of the infected epithelium to cervical precancer, and further invasion. Although these fundamental steps are well established, several new genetic and immunologic studies have shed light on the factors that influence each of these transitions. Over 150 different HPV subtypes have been identified so far, with a subset of these being classified as high risk for oncogenesis. Persistent infection with oncogenic HPV is the main cause of cervical cancer. Polymerase-chain-reaction (PCR)-based assays show that HPV DNA exist in around 90.7- 96.6% patients with cervical cancer and in 13.4 -15.6% control women. About the detected HPV types in patients, in descending order of frequency, are types 16, 18, 45, 31, 33, 52, 58, and 35. Fifteen HPV types are classified as high-risk types (16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 68, 73, and 82); 3 are classified as probable high-risk types (26, 53, and 66); and 12 are classified as low-risk types (6, 11, 40, 42, 43, 44, 54, 61, 70, 72, 81). The most frequently detected high risk HPV types (HPV 16, 51, 52, and 59) are similar in male of different sites, which is compatible with the female incidence.
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-high risk HPV and its antigen (high-risk HPV) present in patients. The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats. In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (high-risk HPV) in the test specimens. From assessment of the electric signature of semiconductive anti- high-risk HPV antibodies, the eABprobe could offer sensitive detection and precise quantification of high-risk HPV.
To develop a real-time diagnostic technique with e- Ab sensor for high risk HPV detection, the investigators conduct a prospective clinical study. In comparison with results from direct sequencing of HPV, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction (such as detection of low risk HPV). The potential factors which may interfere with the results would be investigated. e- Ab sensor threshold decisions must maximize its sensitivity. Therefore, the threshold value in the test group is to find the decision could have 90% sensitivity and 90% specificity.With such a real-time diagnostic technique, the investigators hope to obtain information of patients in cost-saving and time-saving way and can give patients early treatment and offer more individualized treatment for our patients.
研究の種類
入学 (予想される)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Taipei、台湾、10051
- 募集
- National Taiwan University Hospital
-
コンタクト:
- Bor-Ching Sheu, MD, PhD
- 電話番号:71963 886-2-23123456
- メール:bcsheu@ntu.edu.tw
-
主任研究者:
- Bor-Ching Sheu, MD,PhD
-
-
参加基準
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- A:The patients with confirmed or suspected infection.
- B: The patients without disease.
Exclusion Criteria:
- The patients with chronic diseases or medical disease
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:1
|
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-high risk HPV and its antigen (high-risk HPV) present in patients.
The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats.
In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (high-risk HPV) in the test specimens.
From assessment of the electric signature of semiconductive anti- high-risk HPV antibodies, the eABprobe could offer sensitive detection and precise quantification of high-risk HPV.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
The performance of e- Ab sensor
時間枠:1 Day
|
In comparison with results from direct sequencing of HPV, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.
|
1 Day
|
協力者と研究者
捜査官
- 主任研究者:Bor-Ching Sheu, MD,PhD、National Taiwan University Hospital
研究記録日
主要日程の研究
研究開始
一次修了 (予想される)
研究の完了 (予想される)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
- 201005076R
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。