Portico TAVI Implant With Transfemoral Delivery System
Assessment Of The St. Jude Medical Portico™ Transcatheter Aortic Valve Implant (TAVI) And The SJM TAVI Transfemoral Delivery System (Portico TF EU)
調査の概要
詳細な説明
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Leicester、イギリス
- Glenfield Hospital
-
London、イギリス
- St. Thomas' Hospital
-
London、イギリス
- Kings College
-
Plymouth、イギリス
- Derriford Hospital, Plymouth
-
-
Northern Ireland
-
Belfast、Northern Ireland、イギリス、BT12 6BA
- Royal Victoria Hospital
-
-
-
-
-
Leeuwarden、オランダ
- Medical center Leeuwarden
-
-
-
-
-
Adelaide、オーストラリア
- Adelaide Royal Hospital
-
-
-
-
-
Copenhagen、デンマーク
- Rigshospitalet Copenhagen
-
-
-
-
-
Bad Nauheim、ドイツ
- Kerckhoff Klinik
-
Bernau、ドイツ
- Heart Center Bernau
-
Hamburg、ドイツ
- Asklepios Klinik-St. Georg
-
Jena、ドイツ
- Klinikum der Universität Jena
-
Karlsruhe、ドイツ
- Klinik fur Herzhirurgie Karlruhe GmbH
-
Leipzig、ドイツ
- Herzzentrum Leipzig
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Subject has given written study Informed Consent for participation prior to procedure.
- Subject is ≥ 18 years of age or legal age in host country.
- Subject's aortic annulus diameter meets the range indicated in the Instructions for use as measured by echocardiogram (echo) or CT conducted within the past 90 days.
- Subject has senile degenerative aortic stenosis with echocardiography (echo) derived mean gradient >40mmHg or jet velocity greater than 4.0 m/s or an initial valve area of <1.0 cm2 (or aortic valve area index ≤ 0.6 cm2/m2). (Baseline measurement taken by echo within 30 days of procedure).
- Subject has symptomatic aortic stenosis as demonstrated by NYHA Functional Classification of II or greater.
- Subject is deemed high operable risk and suitable for TAVI per the medical opinion of the Subject Selection Committee (See Section 3.1 for the definition of the Subject Selection Committee)
- Subject's predicted operative mortality or serious, irreversible morbidity risk is <50% at 30 days.
- In the opinion of the Subject Selection Committee and based upon angiographic measurements, the subject has suitable peripheral vessels and aorta to allow for access of the 18 French delivery system.
- Subject has structurally normal cardiac anatomy.
- Subject is willing and able to comply with all required follow-up evaluations.
Exclusion Criteria:
- Subject has a history of a cerebral vascular accident (CVA) or transient ischemic attack (TIA) within the past 6 months (≤180 days) of the index procedure.
- Subject has carotid artery disease requiring intervention.
- Subject has evidence of a myocardial infarction (MI) within the past 6 months (≤180 days) of the index procedure.
- Subject has hypertrophic cardiomyopathy.
- Subject has a native aortic valve that is congenitally unicuspid, bicuspid, quadricuspid or non-calcified as seen by echocardiography.
- Subject has mitral or tricuspid valvular regurgitation (>grade III) or moderate to severe mitral stenosis.
- Subject has aortic root angulation >70 degrees (horizontal aorta).
- Subject has a pre-existing prosthetic valve or prosthetic ring in any position.
- Subject refuses blood transfusion or surgical valve replacement.
- Subject has left ventricular ejection fraction (LVEF) < 20%.
- The subject has documented, untreated coronary artery disease (CAD) requiring revascularization.
- Subject has severe basal septal hypertrophy.
- Subject has had a percutaneous interventional or other invasive cardiac or peripheral procedure ≤ 14 days of the index procedure.
- Subject has a history of or has active endocarditis.
- Subject has echocardiographic evidence of intracardiac mass, thrombus, or vegetation.
- Subject has hemodynamic instability (requiring inotropic support or mechanical heart assistance).
- Subject is in acute pulmonary edema or requiring intravenous diuretic therapy to stabilize heart failure.
- Subject with significant pulmonary disease.
- Subject has significant chronic steroid use.
- Subject has a known hypersensitivity or contraindication to anticoagulant or antiplatelet medication.
- Subject has renal insufficiency as evidenced by a serum creatinine > 3.0 mg/dL (265µmol/L) or end-stage renal disease requiring chronic dialysis.
- Subject has morbid obesity defined as BMI ≥ 40.
- Subject's iliac arteries have severe calcification, tortuosity (>two 90 degree bends), diameter <6mm, or subject has had an aorto-femoral bypass.
- Subject has ongoing infection or sepsis.
- Subject has blood dyscrasias (leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis, or coagulopathy).
- Subject has a current autoimmune disease that, in the opinion of the Principal Investigator precludes the subject from study participation.
Subject has significant aortic disease, including:
- aortic abdominal aneurysm (AAA) ≥ 4cm
- thoracic aneurysm (defined as a maximal luminal diameter of 5 cm or greater)
- marked tortuosity
- significant aortic arch atheroma or narrowing of the abdominal or thoracic aorta
- severe tortuosity of the thoracic aorta.
- Subject has a pre-existing endovascular stent graft in the supra- or infrarenal aorta or pre-existing stent grafts in the ileo-femoral arteries.
- Subject has an active peptic ulcer or has had gastrointestinal (GI) bleeding within the past 90 days prior to the index procedure.
- Subject is currently participating in another investigational drug or device study.
- Subject requires emergency surgery for any reason.
- Subject has a life expectancy < 12 months.
- Subject has other medical, social or psychological conditions that, in the opinion of the Subject Selection Committee, preclude the subject from study participation.
- Subject is suffering from dementia or admitted to a chronic care facility which would fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits.
- Subject has a known allergy to contrast media, nitinol alloys, porcine tissue, or bovine tissue.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Transfemoral Access
Transfemoral Access for transcatheter aortic valve implant
|
Placement of the SJM Portico aortic valve with a transfemoral delivery system
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
All Cause Mortality
時間枠:30 days
|
Number of participants that reported all cause mortality
|
30 days
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Number of Select Cardiovascular Adverse Events
時間枠:30 days
|
Number of participants with select cardiovascular adverse events
|
30 days
|
|
Participant NYHA Classification at Day 30
時間枠:day 30
|
The New York Heart Association (NYHA) functional classification system relates symptoms to everyday activities and the patient's quality of life. Class I. Patients with cardiac disease but without resulting limitation of physical activity. Class II. Patients with cardiac disease resulting in slight limitation of physical activity. They are comfortable at rest. Class III. Patients with cardiac disease resulting in marked limitation of physical activity. They are comfortable at rest. Class IV. Patients with cardiac disease resulting in inability to carry on any physical activity without discomfort. Symptoms of heart failure or the anginal syndrome may be present even at rest. The Criteria Committee of the New York Heart Association. Nomenclature and Criteria for Diagnosis of Diseases of the Heart and Great Vessels. 9th ed. Boston, Mass: Little, Brown & Co; 1994:253-256. |
day 30
|
|
Number of Participants With Acute Device Success
時間枠:7 days
|
|
7 days
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Ganesh Manoharan, MD、Royal Victoria Hospital
出版物と役立つリンク
一般刊行物
- Walther T, Manoharan G, Linke A, Mollmann H, Holzhey D, Worthley SG, Kim WK, Schafer U. Incidence of new-onset left bundle branch block and predictors of new permanent pacemaker following transcatheter aortic valve replacement with the Portico valve. Eur J Cardiothorac Surg. 2018 Sep 1;54(3):467-474. doi: 10.1093/ejcts/ezy078.
- Linke A, Holzhey D, Mollmann H, Manoharan G, Schafer U, Frerker C, Worthley SG, van Boven AJ, Redwood S, Kovac J, Butter C, Sondergaard L, Lauten A, Schymik G, Walther T. Treatment of Aortic Stenosis With a Self-Expanding, Resheathable Transcatheter Valve: One-Year Results of the International Multicenter Portico Transcatheter Aortic Valve Implantation System Study. Circ Cardiovasc Interv. 2018 Feb;11(2):e005206. doi: 10.1161/CIRCINTERVENTIONS.117.005206.
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。