Wrist NIBP During Elective Cesarean Delivery
Comparison of Arm and Forearm Blood Pressure During Elective Cesarean Delivery
調査の概要
詳細な説明
Upper arm non-invasive blood pressure (NIBP) measurement is the most commonly accepted method of blood pressure (BP) monitoring. During a cesarean delivery it may be challenging to obtain an accurate measurement from the automated devices in over 50% of the attempts due to arm movement.1 Patients may voluntarily move their arm, but more often neuraxial (spinal, epidural, combined spinal-epidural) anesthesia is known to induce shivering that causes the patient's arm to shake.2 To eliminate the effect of movement of the upper arm, NIBP has been tested on the leg because it is immobilized during neuraxial anesthesia. However, studies monitoring NIBP on an ankle or a calf were unable to accurately detect changes (increase or decrease) in blood pressure in patients undergoing a cesarean delivery.3,4 It seems clinically reasonable that in the case of a shivering patient, the forearm, with less muscle mass, would shake less and could be stabilized more easily than the upper arm (stabilizing the forearm is easily done by holding the patient's hand with a light pressure on the arm rest). Therefore, positioning an NIBP cuff on the forearm (near the wrist) may be useful to obtain an accurate blood pressure measurement in shivering patients.
Previous studies have found that forearm BP overestimates blood pressure measured at the upper arm in a variety of clinical settings and patient populations under static (patient at rest, not submitted to an intervention that might alter BP) circumstances.5-8 It is unknown whether this overestimation is clinically relevant when blood pressure change occurs rapidly, such as during a cesarean delivery. During neuraxial anesthesia for cesarean delivery, it is important for the anesthesiologist to know both absolute values and clinically significant changes in blood pressure to determine their treatment. The detection of dynamic changes in blood pressure (as when the patient is submitted to an intervention that might alter BP per se, e.g. neuraxial anesthesia) has been studied in obstetric patients. Nevertheless, either due to the location where the BP cuff was placed4 (as on the lower limb with interference of the aorto-caval compression) or to the technology used to measure blood pressure,9 (the penaz technology was not consistent with oscillometric technology in a previous study) the forearm blood pressure was not comparable to upper arm blood pressure when measured using an oscillometric monitor.
This study will compare the upper arm (the current gold-standard) and the forearm NIBP measurements in patients undergoing an elective cesarean delivery under subarachnoid anesthesia. We hypothesize that the forearm systolic BP measurement values will be within 10% (lower or higher) of the systolic BP values measured in the upper arm at the same time-points
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
British Columbia
-
Vancouver、British Columbia、カナダ、V6H 3N1
- British Columbia's Women's Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Healthy (American Society of Anesthesiologist's (ASA) physical status I or II) patients
- Having an elective cesarean delivery under spinal or combined spinal epidural anesthesia
- ≥19 years old
Exclusion Criteria:
- Contra-indication to neuraxial anesthesia
- General anesthesia for any reason prior to delivery of the baby
- Use of the epidural component (epidural top-up) of combined spinal epidural anesthesia (prior to delivery of the baby)
- History of cardiovascular disease, e.g. hypertension (either essential or pregnancy-induced)
- A difference of more than 10% between both upper arms and forearms in mean blood pressure measurement prior to surgery (see below)
- BMI >35kg/m2 (it is more difficult to ensure the cuff size is correct in these obese patients)
- Inability to read and understand English for the purpose of informed consent
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
|---|
|
Pregnant women
Pregnant women undergoing a cesarean section
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Compare trends in NIBP measurements between the upper arm and forearm
時間枠:30 minutes
|
Measure NIBP at the upper arm and forearm simultaneously during surgery.
NIBP cuffs will be on opposite arms.
|
30 minutes
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
To estimate the accuracy of blood pressure measured on the forearm
時間枠:30 minutes
|
30 minutes
|
協力者と研究者
捜査官
- 主任研究者:Simon Massey, MD、University of British Columbia, BC Women's Hospital
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- H12-01797
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。