One Year Outcome Using the Ajust System for Treatment of Urinary Stress Incontinence
During the last decade numerous new procedures have been presented regarding surgical treatment of urinary stress incontinence (1,2). Development of the midurethral tape procedure (TVT) changed the surgical procedure dramatically both regarding the extent of the surgical procedure and also decreased the morbidity remarkably. The success rate of the TVT procedure has been proven to be high (1,2 ). However, the development of the TOT/TVT-O procedures disclosed a new fixation point and further decreased the risk of bladder injury (1,2). Since the introduction of trans-obturator slings several mini-slings have been introduced in order to reduce the need of perforation of the skin and muscles (3,4,5). Although some systems seem promising (5) others have disclosed a long learning curve, pain problems following the procedure and lower success rates, compared to the traditional sling procedures. None of these mini-slings have been adjustable.
Recently the Ajust system for treatment of stress urinary incontinence was introduced. The system is a single incision sling procedure and consists of an adjustable Polypropylene mesh sling with self fixation anchors (6). In a feasibility study (6), the 6 months objective cure rate was 82%, but there is a lack of information regarding adverse events and durability of treatment success. Our preliminary experiences suggest, that the procedure has a rapid learning curve, low pain scores postoperatively and a 94% cure rate at 3 months follow-up (personal observation). Recently, several abstracts have indicated that the cure rate obtained by Ajust is comparable to TVT or TVT-O (10-12).
The purpose of the present study is (primary outcome):
To test the hypothesis that the Ajust and TVT, TVT-O and TOT, respectively are equal regarding subjective cure rate (cure is defined as subjectively not incontinent at all), i.e. the study is designed as a non-inferiority study. The study is performed as a randomised controlled trial without blinding. The study is powered to detect a 9% difference between the two groups. The subjective cure rate is based on ICIQ measurement
Secondary outcome:
- To test the hypothesis that Ajust is associated with a significantly lower postoperative pain perception.
- To test the hypothesis that antibiotic treatment is not necessary
調査の概要
詳細な説明
Primary endpoint: A cured patients is defined as no subjective symptoms (ICIQ-UI SF and ICIQ-OAB) and no objective detectable urinary leakage during coughing (300cc in the bladder and no leakage during coughing)
Secondary outcome: Pain-perception is evaluated by VAS scoring daily during the first postoperative week, including assessing the need for painkilling medication
The endpoint regarding the use of antibiotics is based on the number of urinary tract infections and infections related to the vaginal closure during the first postoperative months. All patients will evaluated postoperative by physical examination and by urinary dipstick
研究の種類
入学 (予想される)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Roskilde、デンマーク、4000
- martin Rudnicki
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- 1. A medical history of stress urinary incontinence, i.e. leakage during coughing, sneezing or leakage during physical exertion. OR 2. A medical history of mixed urinary stress incontinence defined as complaint of involuntary leakage associated with urgency and stress incontinence. Stress incontinence has to the dominating symptom defined as more episodes of leakage due to coughing or physical exertion than with urgency.
3. A provocative stress test up to ten coughs at a standardized bladder volume (300 ml) confirming urinary leakage from the urethra while the patient is asked to cough or perform a Valsalva manoeuvre standing or lying (7). Furthermore, the patient has to present hypermobility of the urethra/bladder neck defined as significant downward rotation when coughing or during Valsalva.?
Exclusion Criteria:
- Previous anti-incontinence surgery.
- Residual urine volume >100 ml
- Bladder capacity <200ml according to diary.
- Planned or current pregnancy
- Repeated urinary tract infections (>4 cystitis last year )
- Current anticoagulation therapy that can´t be interrupted in due time prior to surgery
- Known abnormal coagulation
- Allergy to local anaesthetics
- Co-existing pelvic pathology, such as ovarian mass etc
- Vaginal POPQ anterior prolapse grade >=2
- A medical history of predominantly urge urinary incontinence.
- Patients unable to understand the protocol and a follow up
- Patients younger than 18 and above or equal to 60 years.
- Known or suspected neurological condition
- Patients who have not paused acethylsalicylic acid (ASA) medication 7 days prior to surgery
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Ajust sling
The sling a a new device for stress urinary incontinence.
The sling is ajustable and is not penetrating the skin, i.e. is only attached to the obturator membrane
|
The use of Ajust system for stress incontinence
sling surgery
|
|
実験的:TVT/TVT-O, polypropylne slings
TVT/TVT-O system.
These two systems is wellknown and used for treatment of stress urinary incontinence.
The sling penetrate the skin in order to secure adjustment.
|
The use of Ajust system for stress incontinence
sling surgery
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
A change in number of cured patients
時間枠:Up to 1 year
|
Primary endpoint: A change in number of cured patients. The number of patients cured is anticipated to be equal in each group. A cured patients is defined as having no subjective symptoms (i.e. no scores on the ICIQ-UI SF and ICIQ-OAB) and no objective detectable urinary leakage during coughing (300cc in the bladder and no leakage during coughing. |
Up to 1 year
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Pain-perception following surgery
時間枠:Evaluated the first week following surgery, and at three and 12 months follow-up
|
Secondary outcome: Pain-perception is evaluated by VAS scoring daily during the first postoperative week, including assessing the need for painkilling medication The endpoint regarding the use of antibiotics is based on the number of urinary tract infections and infections related to the vaginal closure during the first postoperative months. All patients will evaluated postoperative by physical examination and by urinary dipstick |
Evaluated the first week following surgery, and at three and 12 months follow-up
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
number of urinary tract infections and infections related to the vaginal closure during the first postoperative months.
時間枠:Evaluated during the first week of follow-up and at 3 months follow-up
|
The endpoint regarding the use of antibiotics is based on the number of urinary tract infections and infections related to the vaginal closure during the first postoperative months.
All patients will evaluated postoperative by physical examination and by urinary dipstick
|
Evaluated during the first week of follow-up and at 3 months follow-up
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Temtanakitpaisan T, Buppasiri P, Lumbiganon P, Laopaiboon M, Rattanakanokchai S. Prophylactic antibiotics for preventing infection after continence surgery in women with stress urinary incontinence. Cochrane Database Syst Rev. 2022 Mar 29;3(3):CD012457. doi: 10.1002/14651858.CD012457.pub2.
- Rudnicki M, von Bothmer-Ostling K, Holstad A, Magnusson C, Majida M, Merkel C, Prien J, Jakobsson U, Teleman P. Adjustable mini-sling compared with conventional mid-urethral slings in women with urinary incontinence. A randomized controlled trial. Acta Obstet Gynecol Scand. 2017 Nov;96(11):1347-1356. doi: 10.1111/aogs.13205. Epub 2017 Sep 15.
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。