このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Outpatient Reduction of Nocturnal Hypoglycemia by Using Predictive Algorithms and Pump Suspension in Children (PSO4)

2016年8月26日 更新者:Jaeb Center for Health Research

The purpose of this study is to see whether low blood sugar at night can be reduced by using a system that turns off the insulin pump automatically. The study system includes a continuous glucose monitor (CGM) and an insulin pump. The CGM and pump work with a regular laptop computer. A The system works by (1) measuring the glucose levels under the skin with the CGM, (2) using a computer program on the laptop to predict whether a low blood sugar is likely to occur, and (3) turning off the insulin pump when the computer program predicts that a low blood sugar will occur.

We have tested the system in the home environment in individuals with type 1 diabetes age 15 years and older. We have found an indication that the system can decrease the frequency of hypoglycemia. We have not had any serious cases of high blood sugars or other problems. We are now ready to further test the system in the home environment in a younger age group to learn more about its ability to reduce overnight low blood sugar risk.

This study has several phases and will take about 3 months for a patient to complete.

  • First, the patient will use the CGM and pump at home for up to 15 days with the help of a parent/guardian. This is done to determine if the patient meets our study criteria to proceed with the next phase of the study.
  • If the patient is eligible to continue in the study, the patient will need to use the full study system for at least 5 nights at home with the help of a parent/guardian. This is done to make sure the patient and parent/guardian are able to use the system correctly. The patient may participate in starting and stopping the system at home, but the parent/guardian is responsible for making sure it is used as instructed.
  • After that, the patient will be asked to use the study system each night for an additional 6 to 8 weeks. The parent/guardian will remain responsible for making sure the system is used as instructed.

The study will include about 90 individuals with type 1 diabetes at 3 clinical centers in the United States and Canada. First a study of children 8 to less than 15 years old will be done. Then, a study of children 3 to less than 8 years old will be conducted.

調査の概要

状態

完了

条件

詳細な説明

Patients who are eligible for the clinical trial initially will use a Veo insulin pump and Enlite sensor at home to verify that the patient is able to use the continuous glucose monitor (CGM) and insert sensors and is eligible to continue in the study. A parent or guardian of the child subject will oversee the actions of the subject and be responsible for the patient's overall participation during the proposed study, including operation of the investigational device system.

The first 10 patients 8 to <15 years of age will participate in an Algorithm Assessment Phase of approximately 10 nights of active system use each (for a nominal total of 100 nights of use) to determine if any adjustments to the algorithm parameters are needed and if it is safe to advance to a randomized clinical trial phase with these subjects. If adjustments are needed, the Algorithm Assessment Phase will be repeated, using the same 10 patients if possible. Once the randomized clinical trial phase begins for patients 8 to <15 years of age, approximately 200 nights of randomized system use will be collected and assessed for safety before any patients 3 to <8 years of age may be enrolled in the study. When enrollment does begin for patients 3 to <8 years of age, a second Algorithm Assessment Phase will be conducted with the first 10 patients in that younger age group using the same approach described above for the older subjects. Once the randomized clinical trial phase begins for patients 3 to <8 years of age, a final Data Safety Monitoring Board safety assessment will be performed after approximately the first 200 nights of randomized system use.

Patients who enroll in the study after the completion of the Algorithm Assessment Phase for their age group will use the closed-loop system at home for at least 5 days to demonstrate their ability to use the system and submit study data to the Coordinating Center.

Patients who successfully demonstrate their ability to use the system at home as described above will be eligible for the randomized trial phase. This phase consists of use of the full system as an outpatient for approximately 42 nights:

  • Each night the blood glucose (BG) level will be checked with the BG meter and used to perform a calibration of the CGM. This calibration must occur no more than 90 minutes prior to activation of the system. NOTE: Subjects will be instructed to calibrate the CGM per manufacturer guidelines.
  • Then the system will be activated, linking the CGM and insulin pump to the computer at the bedside.
  • A randomization schedule on the laptop will be used to determine whether the 'pump shut off' application will be active that night or not.
  • Patients will be blinded as to whether the pump shut off is active when a session is initiated each night.
  • There will not be an alarm if the pump shuts off. The CGM alarm will be set to 60 mg/dL (3.3 mmol/L). When a CGM alarm occurs, the subject will be asked to measure the blood glucose with a BG meter, if he/she is aware of the alarm.
  • Patients will be asked to check blood ketones with the study ketone meter if the subject has a fingerstick BG ≥250 mg/dL (13.9 mmol/L).
  • Patients will be asked to check blood glucose with the study BG meter, blood ketones with the study ketone meter, and urine ketones with a ketone strip each morning prior to breakfast and enter the results using the controller software interface. The patient will be instructed to contact the study physician if the blood glucose or ketone readings are out of an expected range.
  • Patients will be asked to record all overnight carbohydrate intake using the controller software interface.
  • Patients will be asked to perform periodic CGM data uploads using the controller software interface.

Upon completion of the study, patients as well as study clinicians will be asked to complete a human factors usability questionnaire regarding use of the study system.

研究の種類

介入

入学 (実際)

97

段階

  • フェーズ2

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • California
      • Stanford、California、アメリカ、94305
        • Stanford University
    • Colorado
      • Aurora、Colorado、アメリカ、80045
        • Barbara Davis Center for Childhood Diabetes
    • Ontario
      • London、Ontario、カナダ、N6A4V2
        • St. Joseph's Health Care

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

3年~14年 (子)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Clinical diagnosis of type 1 diabetes and using daily insulin therapy for at least one year and an insulin infusion pump for at least 6 months
  • Age 3 to <15 years
  • HbA1c <=8.5%
  • Availability of internet access for periodic upload of study data

Exclusion Criteria:

  • Diabetic ketoacidosis in the past 3 months
  • Hypoglycemic seizure or loss of consciousness in past 6 months
  • History of seizure disorder (except for hypoglycemic seizures)
  • Cystic fibrosis
  • Current use of oral/inhaled glucocorticoids, beta-blockers or other medications, which in the judgment of the investigator would be a contraindication to participation in the study
  • History of ongoing renal disease (other than microalbuminuria), or liver disease (Creatinine is > 1.5 mg/dL (132 µmol/L))
  • Medical or psychiatric condition that in the judgment of the investigator might interfere with the completion of the protocol such as:

    • Inpatient psychiatric treatment in the past 6 months
    • Uncontrolled adrenal disorder
    • Abuse of alcohol
  • Pregnancy
  • Liver disease as defined by an Alanine Aminotransferase Test (ALT) greater than 3 times the upper limit of normal

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:防止
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
アクティブコンパレータ:Pump suspension algorithm
The pump suspension algorithm will be running actively on the study laptop during the night and suspend the pump if the algorithm predicts hypoglycemia.
The study laptop will communicate to the pump causing a suspension based on output from the algorithm which predicts hypoglycemia.
介入なし:Standard of Care
The control algorithm will run passively and not suspend the patient's pump.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Comparison of the Time Spent in Hypoglycemia (<70 mg/dl, 3.9 mmol/L) Overnight on Intervention Nights Versus Control Nights, Normalized to an 8-hour Period.
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use.
Each night is categorized as to whether hypoglycemia occurred. Hypoglycemia is defined as the occurrence of one or more CGM glucose values ≤70 mg/dL (3.9 mmol/L). The time period for outcome assessment each night will be from the time the system is activated in the evening until the time it is deactivated in the morning. The percentage of hypoglycemic nights (CGM glucose value ≤70 mg/dL (3.9 mmol/L)) will be tabulated separately with versus without the closed-loop control system in use. We considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use.

二次結果の測定

結果測定
メジャーの説明
時間枠
Percentage of Nights With 1 or More Sensor Glucose Values <70 mg/dL (<3.9 mmol/L)
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use.
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use.
Percentage of Nights With 1 or More Sensor Glucose Values <50 mg/dL (<2.8 mmol/L)
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Mean Sensor Glucose Overnight
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Percentage of Time Overnight Sensor Glucose Values 71 to 180 mg/dL (3.9 to 10.0 mmol/L), Normalized to an 8-hour Period.
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Percentage of Overnight Time Spent With CGM Value >250 mg/dL (13.9 mmol/L), Normalized to an 8-hour Period.
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Mean Morning Blood Glucose
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Percentage of Mornings With Blood Glucose >250 mg/dL (>13.9 mmol/L)
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Morning Blood Ketones >=1.0 mmol/L
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Please note we considered nights with at least 4 hours of sensor glucose data as a "valid" night toward the 42 night overall goal and thus our final analyses had a slightly higher number of nights than expected.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Percent of Mornings With Urine Ketones >/= 15 mg/dl
時間枠:Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use
Urine ketones measured each morning with Ketostix.
Overnight from system activation to deactivation in the morning upon awakening for 42 nights of system use

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • スタディディレクター:John Lum, MS、Jaeb Center for Health Research
  • スタディチェア:Bruce A Buckingham, MD、Stanford University

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2013年5月1日

一次修了 (実際)

2014年9月1日

研究の完了 (実際)

2014年9月1日

試験登録日

最初に提出

2013年3月29日

QC基準を満たした最初の提出物

2013年4月2日

最初の投稿 (見積もり)

2013年4月4日

学習記録の更新

投稿された最後の更新 (見積もり)

2016年8月30日

QC基準を満たした最後の更新が送信されました

2016年8月26日

最終確認日

2016年8月1日

詳しくは

本研究に関する用語

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する