Feasibility of the Vapor Nanobubble Technology for Malaria Diagnostics (MalariaSense) (MalariaSense)
Feasibility of the Vapor Nanobubble Technology (MalariSense) for Malaria Diagnostics
調査の概要
詳細な説明
This is a proof of concept study that will evaluate the feasibility of a vapor nanobubble technology (MalariSense) for malaria diagnostics. The primary objective is to determine the sensitivity of MalariSense against microscopy in diagnosing malaria in malaria suspected cases attending a health facility in The Gambia. The secondary objectives include the following;
- To determine the sensitivity of MalariSense against PCR in diagnosing malaria in malaria suspected cases attending a health facility in The Gambia
- To determine the specificity of MalariSense in diagnosing malaria in malaria suspected cases attending a health facility in The Gambia.
- To identify factors influencing the diagnostic accuracy of MalariSense
- To validate the protocol for a blood vessel identification for the test and assess the safety of the prototype The study site will be Basse in the Eastern region of The Gambia. The study will be conducted during the malaria transmission season (August to December 2015). Participants will be patients with suspected uncomplicated malaria presenting to the outpatient department of Basse Health centre. At baseline, suspected malaria cases (clinical assessment) will be asked to provide informed consent and then transferred to the MRC Basse field station where a finger prick blood sample will be collected for a malaria rapid diagnostic test (RDT), microscopy and on filter paper for subsequent molecular studies. In addition, they will be tested using the Malarisense Technology. Measurements will be taken from the wrist, ear lobe and finger tips. The laboratory prototype of the device will include three major components: pulsed laser with the fiber output, integrated handheld probe with the fiber launch in the center and an ultrasound sensor with pre-amplifier, and the signal acquisition hardware with software.
The study will enrol a total sample size of 50 patients with confirmed malaria. It is estimated that about 125 to 167 suspected cases will need to be screened/tested to get this sample size. The Sample size will be increased by 10% to allow for any missing values - therefore up to 185 suspected cases screened. In addition, a convenience sample of 30 malaria negative participants will be enrolled for comparisons between malaria positive and malaria negative populations. RDT positive patients will be provided with antimalarial treatment while the others will receive treatment according to their condition. Microscopy and species-specific PCR will be performed later. Microscopy results will be taken as the gold standard.
There will not be any active follow up. Study participants will be asked to come back 2 days after the test, or earlier if they notice a problem.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Basse, Upper River Region、ガンビア
- Basse Health Centre
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Patients presenting to the health facility with suspected uncomplicated malaria
- Provision of informed consent
Exclusion Criteria:
- Neonates and under 12 months old
- Pregnant women
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:MalariaSense device
This study will involve the evaluation of a medical diagnostic device.
All participants enrolled in the study will be assessed for malaria using MalariSense Technology and will aslo get rapid diagnostic tests (RDTs), microscopy, PCR
|
All participants enrolled in the study will be assessed for malaria using the intervention device called MalariaSense technology
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
"Hemozoin-generated vapour nanobubble (H-VNB) amplitude thresholds among malaria infected and uninfected individuals"
時間枠:Day 1
|
Day 1
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Safety profile of Malarisense technology for malaria diagnosis
時間枠:Day 1 - Day 3
|
Safety of the MalariSense Technology for malaria diagnosis over 3 days of observation
|
Day 1 - Day 3
|
|
Correlation of incidence rate ratio of hemozoin-positive traces with level of parasite density as determined by microscopy
時間枠:Day1 - Day 3
|
Day1 - Day 3
|
協力者と研究者
捜査官
- 主任研究者:Umberto D'alessandro, PhD, MD、Medical Research Council Unit, The Gambia
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。