このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

The Vizio Clinical Study

2026年7月8日 更新者:Ocumedex

The Vizio Clinical Study: A Prospective, Multicenter, Feasibility Clinical Study to Evaluate the Safety and Efficacy of the Vizio Aqueous Microshunt for the Treatment of Refractory Glaucoma

Evaluate the Safety and Efficacy of the Vizio Aqueous Microshunt for the Treatment of Refractory Glaucoma

調査の概要

詳細な説明

Glaucoma is a leading cause of irreversible blindness in the world and remains a largely unmet clinical need, especially for trial participants with refractory glaucoma. Available aqueous drainage devices may reduce IOP, but often require continued use of medications. Ocumedex is testing the Vizio Aqueous Microshunt (VAM), a promising medical device engineered to safely and consistently lower IOP to a threshold (approximately 12 mmHg) that may halt further damage to the optic nerve without the use of supplemental medication. The Vizio Aqueous Microshunt is a next generation device initially developed by MicroOptx, Inc. In early 2023, Innomedex, LLC acquired the assets of MicroOptx and formed the company, Ocumedex Inc. Ocumedex is now sponsoring the Vizio Clinical Study based on the product development that was conducted by MicroOptx under an ISO13485 compliant quality system inclusive of all development testing that is required prior to human use.

MicroOptx, developed a first-generation device which was named the Beacon Aqueous Microshunt. The Beacon device had undergone early clinical trials in the United States, Canada and Germany in which 55 trial participants were implanted and clinically followed. The results of this clinical work clearly demonstrated the efficacy endpoint of significantly reducing intraocular pressure and alleviating the need for medications. The safety endpoint of the Beacon device had an adverse event rate that was higher than expected and hence further product development was initiated. The elevated adverse event rate was attributed to healing response of the first-generation material, implantation technique andtrial participant selection. Based on this information, the next generation device, Vizio, was developed with a new implant material which has demonstrated significantly improved healing in GLP animal studies.

Additionally, physician training and proctoring has been refined to ensure proper device implantation as well as refined inclusion/exclusion criteria to ensure proper trial participant selection.

Ocumedex is committed to developing technology that is safe and efficacious for the treatment of trial participants suffering from the devasting disease of glaucoma. With product improvements validated by bench and animal testing in addition to clinical trial rigor implemented, the Vizio product is set to initiate human implants and have a meaningful impact for trial participants.

Additionally, unlike other surgical options available, the Vizio device shunts aqueous humor from the anterior chamber to the surface of the eye. This distinction is important: 1) Vizio drains aqueous humor into an open space with a known pressure (atmospheric), which may improve predictability and consistency of IOP control (vs. draining into a closed space, such as bleb or episcleral venous pressure); and 2) Shunting aqueous humor to the tear film, providing lubrication to the eye and improving ocular surface symptoms which are common in trial participants with glaucoma.

研究の種類

介入

入学 (推定)

50

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

研究場所

    • San Salvadore
      • Colonia Escalón、San Salvadore、エルサルバドル
        • 募集
        • Centro de Diabetes Ocular El Dios de Israel, S.A
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  1. Age 22-85 years
  2. Refractory glaucoma describes eyes diagnosed with glaucoma specific to one of the following:

    • uncontrolled by maximally tolerated medical therapy
    • failed one or more incisional intraocular glaucoma surgeries (e.g., glaucoma filtering surgery or tube shunt)
    • failed one or more cilioablative procedures (e.g., cryotherapy, cyclodiode therapy)
    • or have any other condition (e.g., conjunctival scarring, uveitis) in which conventional incisional glaucoma surgery like trabeculectomy would be more likely to fail than for an eye with uncomplicated primary open angle glaucoma.
  3. Primary open-angle or traumatic glaucoma.
  4. Medicated DIOP ≥25 mmHg and ≤45 mmHg on maximum-tolerated medical therapy that is stable for at least 30 days.
  5. Best-corrected baseline visual acuity of light perception or better in study eye.
  6. Glaucomatous optic nerve damage as evidenced by any of the following optic disc or retinal nerve fiber layer structural abnormalities:

    • Diffuse thinning, focal narrowing, or notching of the optic disc rim, especially at the inferior or superior poles with or without disc hemorrhage;
    • Localized abnormalities of the peripapillary retinal nerve fiber layer, especially at the inferior or superior poles; or
    • Optic disc neural rim asymmetry of the two eyes consistent with loss of neural tissue
  7. Visual field mean deviation (MD) by Humphrey Visual Field:

Visual field defects consistent with glaucomatous optic nerve damage and mean deviation worse than -3 dB in the study eye; and at least one of the following two findings:

  • A cluster of 3 or more points in an expected location of the visual field depressed below the 5% level, at least 1 of which is depressed below the 1% level on the pattern deviation (PD) plot;
  • Glaucoma hemi-field test "outside normal limits". 8. At least two contiguous clock hours of intact conjunctiva near the limbus between clock hours of 10:00 and 02:00 in the study eye. 9. Adequate space in the anterior chamber by Spaeth Grade C, D or E for iris insertion (with indentation). 10. Participant has the understanding, ability, and willingness to fully comply with study procedures and postoperative care instructions. 11. Participant understands, is capable and competent to sign the informed consent. Exclusion Criteria

    1. Active neovascular conditions such as active iris or corneal neovascularization, or active proliferative retinopathy in study eye.
    2. Pigmentary glaucoma in study eye.
    3. Angle-closure glaucoma in study eye.
    4. Pseudoexfoliation syndrome in study eye
    5. Iridocorneal endothelial syndrome in study eye.
    6. Uveitic glaucoma in the study eye.
    7. Epithelial or fibrous downgrowth in the study eye.
    8. Corneal conditions in study eye inhibiting normal incisional healing (e.g. Fuch's dystrophy) or impair visualization of implant inside the anterior chamber.
    9. Prior intraocular surgery in study eye within ≤6 months before the preoperative visit (including phacoemulsification).
    10. Central corneal endothelial cell count of less than 1600 cells/mm2 in study eye.
    11. Anticipated need for ocular surgery or retinal laser procedure in the study eye within the 12-month follow-up period.
    12. Need for glaucoma surgery combined with other ocular procedures in study eye at implant (e.g. cataract surgery, penetrating keratoplasty, or retinal surgery).
    13. Unwilling to discontinue contact lens use in the study eye after surgery.
    14. Central corneal thickness ≤490μm or ≥620μm in the study eye.
    15. Clinically significant inflammation or infection in the study eye within 60 days prior to the preoperative visit (e.g., blepharitis, conjunctivitis, keratitis, uveitis, herpes simplex infection) or any systemic infection. For purposes of this study, clinically significant is considered any such condition requiring prescription therapy.
    16. Any condition that prevents the device implantation in the superior region of the study eye.
    17. Vitreous in the study eye anterior chamber for which a vitrectomy is anticipated.
    18. Functionally significant cataract in the study eye.
    19. Other clinical conditions:

      1. Poorly controlled diabetes (Type I or Type II) as determined by HbA1c >8 within 3 months of implant.
      2. Cancer requiring treatment during the duration of the study.
      3. Any drugs (e.g.: immunosuppressive drugs) or co-morbidity that might inhibit wound healing.
    20. Participation in any other clinical study during participation in this study.
    21. Engage in activities that involve submerging their head under water, such as diving or swimming.
    22. Women who are (i) pregnant, (ii) nursing, (iii) planning a pregnancy and (iv) of childbearing potential not using a reliable method of contraception.
    23. Life expectancy <1 year. Note: If both eyes are eligible, the eye with the worse BCVA should be selected

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Vizio Treatment
single-arm clinical study
Ocular microshunt placement for the treatment of Glaucoma

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Efficiency of IOP reduction as measured through Applanation Tonometry
時間枠:12 months
The primary endpoint is a binary measure of at least 20% reduction from baseline in diurnal IOP at twelve months from baseline. IOP will be measured on day 1, week 1, week 2, month 1, month 2, month 3, month 6, month9, and month 12. Baseline and month 12 IOP measurements will be diurnal. Medication use will be monitored during the follow ups and assessed at month 12 to measure whether participant is on the same number or fewer topical IOP-lowering medications, based on intent-to-treat population.
12 months
Safety of the Vizio device and procedure as monitored through adverse event reporting. Incidence of Treatment-Emergent Adverse Events [Safety and Tolerability]
時間枠:12 months
Rate of occurrence of serious procedure-related and/or device-related adverse events (AEs) observed throughout the study will be reported on the AE CRF. Adverse Events, whether related or unrelated to the investigational medical device, include 1) unintended disease or injury, or 2) any unfavorable or untoward clinical signs (including an abnormal laboratory finding). Adverse events (AEs) will be graded by the Investigator based on severity according to the following: • Mild - An event that is easily tolerated by the participant, causing minimal discomfort and not interfering with daily activities. • Moderate - An event that causes some interference with daily activities and may require minimal medical intervention. • Severe - An event that results in significant interference with daily activities, may be incapacitating, requires medical intervention or hospitalization, or is potentially life-threatening • Life-Threatening: The participant is at immediate risk of death.
12 months

二次結果の測定

結果測定
メジャーの説明
時間枠
Responder Rate
時間枠:12 months
Responder rate for complete success at 12M: Defined as at least 20% mean diurnal IOP reduction from baseline after device implant with no IOP lowering medications
12 months
Overall Safety
時間枠:12 months
Rate of all ocular and non-ocular adverse events (intraoperative complications and postoperative events), including rate of pre-specified ocular adverse events (per ANSI Z80.27) and abnormal findings by pachymetry, slit lamp biomicroscopy, gonioscopy, fundoscopy, specular microscopy and patient-reported symptoms
12 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年3月21日

一次修了 (推定)

2028年1月1日

研究の完了 (推定)

2029年3月1日

試験登録日

最初に提出

2024年8月14日

QC基準を満たした最初の提出物

2024年9月6日

最初の投稿 (実際)

2024年9月19日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月10日

QC基準を満たした最後の更新が送信されました

2026年7月8日

最終確認日

2026年7月1日

詳しくは

本研究に関する用語

追加の関連 MeSH 用語

その他の研究ID番号

  • C100

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する