Novel SaCoVLM™ Video Laryngeal Mask Airway as an Intubation Conduit in Morbidly Obese Bariatric Surgery

2026年5月1日 更新者:Yongtao Sun

Novel SaCoVLM™ Video Laryngeal Mask Airway as an Intubation Conduit in Morbidly Obese Bariatric Surgery: a Single-arm Prospective Study

Background: The SaCoVLM™ video laryngeal mask is a novel video-assisted device that integrates the functions of both a dual-channel laryngeal mask airway (LMA) and an intubating laryngeal mask airway (ILMA). At present, there are relatively few studies on awake airway management for obese patients who undergo laparoscopic sleeve gastrectomy (LSG). To evaluate the efficacy and safety of the SaCoVLM™ video laryngeal mask airway as an intubation conduit in morbidly obese patients undergoing laparoscopic sleeve gastrectomy.

Patients and methods: This single-arm prospective study evaluated the efficacy and safety of the SaCoVLM™ video laryngeal mask airway in 57 morbidly obese patients (BMI ≥35 kg/m²) undergoing LSG.

調査の概要

詳細な説明

All anesthesiologists in this study underwent centralized training prior to trial initiation, with documented certification in protocol-specific procedures. No preoperative medications were administered to any patients. Upon entering the operating room, patients were positioned in a semi-fowler position, with intravenous access established. Standard monitoring protocols were implemented, including electrocardiography (ECG), heart rate (HR), non-invasive blood pressure (NIBP), pulse oximetry (SpO₂), end-tidal carbon dioxide (EtCO₂), and bispectral index (BIS), alongside radial artery catheterization for invasive blood pressure monitoring. All patients underwent awake insertion of the SaCoVLM™, with surgery completed under general anesthesia combining the video laryngeal mask and endotracheal intubation.

Immediately upon arrival in the operating room, patients were instructed to hold 10 mL of dyclonine mucilage orally for approximately 10 minutes to achieve topical anesthesia. Premedication included midazolam 2 mg and atropine 0.4 mg, followed by bilateral ultrasound-guided superior laryngeal nerve block using 0.375% ropivacaine. A properly sized laryngeal mask was selected, and under awake conditions, patients were instructed to open their mouths to facilitate SaCoVLM™. Optimal positioning was confirmed by visualization of complete glottic structures on the monitor screen. The glottic exposure grade was as we previously described. The cuff was inflated using a handheld manometer, and the mask was connected to the anesthesia machine. Clear glottic visualization on the monitor and the presence of a regular EtCO₂ waveform confirmed proper mask alignment, after which rapid anesthesia induction was initiated.

If suboptimal positioning occurred, the up-down maneuver, cricoid pressure, cuff pressure adjustment, fiberoptic bronchoscopy-guided intubation were applied for minor adjustments. Under direct video guidance, the endotracheal tube was gently advanced along the natural curvature of the airway. Successful intubation was defined by unimpeded tube passage, direct visualization of tracheal entry, and sustained EtCO₂ waveform. Following intubation, the breathing circuit was immediately connected, and bilateral lung auscultation confirmed symmetrical breath sounds before securing both the mask and endotracheal tube. Intraoperative fluid administration and vasoactive medications were adjusted based on vital signs, urine output, and physiological requirements.

Postoperatively, the endotracheal tube was removed under deep anesthesia, and the video laryngeal mask was retained for transfer to the post-anesthesia care unit (PACU). The laryngeal mask was removed only after patients regained adequate spontaneous respiration, demonstrated responsiveness to verbal commands, and met established extubation criteria.

研究の種類

観察的

入学 (実際)

57

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Shandong
      • Jinan、Shandong、中国、250014
        • The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

確率サンプル

調査対象母集団

The study population comprised adult patients aged over 18 years (with no upper age limit) diagnosed with morbid obesity.

説明

Inclusion Criteria:

  1. Adult patients aged over 18 years (no upper age limit)
  2. Diagnosed with morbid obesity, clinically defined as either:

Body mass index (BMI) ≥ 40 kg/m², or BMI ≥ 35 kg/m² accompanied by at least one significant obesity-related comorbidity

Exclusion Criteria:

  1. Have no clinical indicators of anticipated difficult airway (Mallampati classification IV, thyromental distance < 6 cm, mouth opening < 3 cm, severe limited neck extension, or a history of difficult airway management)
  2. Demonstrate tolerance for laparoscopic surgery and anesthesia
  3. Be scheduled exclusively for LSG without concurrent additional procedures

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
morbidly obese bariatric surgery
This study was a single-arm prospective study, so there was no grouping.
As part of the awake airway management protocol initiated in the operating room, patients were first instructed to hold 10 mL of dyclonine mucilage orally for approximately 10 minutes to achieve topical oropharyngeal anesthesia. This was followed by intravenous administration of midazolam 2 mg and atropine 0.4 mg, and bilateral ultrasound-guided superior laryngeal nerve block using 0.375% ropivacaine. A properly sized laryngeal mask was selected. The posterior surface of the cuff was lubricated with a water-based surgical lubricant. Under awake conditions, patients were instructed to open their mouths to facilitate SaCoVLM™ insertion. Optimal positioning was confirmed by visualization of complete glottic structures on the monitor screen. The glottic exposure grade was as we previously described . The cuff was inflated using a handheld manometer, and the mask was connected to the anesthesia machine. Clear glottic visualization on the monitor and the presence of a regular EtCO₂ waveform.
As part of the awake airway management protocol initiated in the operating room, patients were first instructed to hold 10 mL of dyclonine mucilage orally for approximately 10 minutes to achieve topical oropharyngeal anesthesia. This was followed by intravenous administration of midazolam 2 mg and atropine 0.4 mg, and bilateral ultrasound-guided superior laryngeal nerve block using 0.375% ropivacaine. A properly sized laryngeal mask was selected. The posterior surface of the cuff was lubricated with a water-based surgical lubricant. Under awake conditions, patients were instructed to open their mouths to facilitate SaCoVLM™ insertion. Optimal positioning was confirmed by visualization of complete glottic structures on the monitor screen. The glottic exposure grade was as we previously described. The cuff was inflated using a handheld manometer, and the mask was connected to the anesthesia machine. Clear glottic visualization on the monitor and the presence of a regular EtCO₂ waveform.

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
the first-time success rate of intubation after insertion of SaCoVLM™
時間枠:Within 10 minutes following SaCoVLM™ placement
Within 10 minutes following SaCoVLM™ placement

二次結果の測定

結果測定
メジャーの説明
時間枠
Time to Successful SaCoVLM™ Insertion (seconds)
時間枠:From the start of device insertion into the mouth until the time of successful SaCoVLM™ placement with first confirmed ventilation, assessed up to 120 seconds. If insertion is not successful within 120 seconds, the event is censored at 120 seconds.
Time to successful insertion is measured in seconds as a continuous time-to-event variable. Successful insertion is defined as proper placement of the SaCoVLM™ with visible chest rise and a square-wave capnography trace. Shorter time indicates a better outcome (faster airway establishment). The primary metric reported will be the median insertion time with interquartile range, along with the proportion of successful insertions within 60, 90, and 120 seconds.
From the start of device insertion into the mouth until the time of successful SaCoVLM™ placement with first confirmed ventilation, assessed up to 120 seconds. If insertion is not successful within 120 seconds, the event is censored at 120 seconds.
Number of SaCoVLM™ Insertion Attempts per Participant
時間枠:From the first insertion attempt until successful SaCoVLM™ placement is achieved or until the procedure is abandoned, assessed during the initial airway management procedure (up to 120 seconds or a maximum of 3 attempts, whichever comes first).
An insertion attempt is defined as any entry of the SaCoVLM™ into the patient's mouth with the intention of placement, regardless of depth or success. Each withdrawal of the device from the mouth followed by re-entry counts as a new attempt. The total number of attempts required to achieve successful placement (confirmed by end-tidal CO₂ waveform) is recorded. Fewer attempts indicate a better outcome (easier insertion). The primary metric reported will be the mean (or median) number of attempts, the range, and the proportion of participants requiring 1, 2, or ≥3 attempts.
From the first insertion attempt until successful SaCoVLM™ placement is achieved or until the procedure is abandoned, assessed during the initial airway management procedure (up to 120 seconds or a maximum of 3 attempts, whichever comes first).
the SaCoVLM™ glottic exposure grades
時間枠:Immediately after SaCoVLM™ placement
Immediately after SaCoVLM™ placement
Oropharyngeal Leak Pressure (OLP) (cm H₂O)
時間枠:Immediately after successful SaCoVLM™ insertion and before start of positive pressure ventilation (measured at a single time point: within 1 minute of confirmation of correct placement)
OLP is measured by closing the adjustable pressure limiting valve of the anesthesia circuit while maintaining a fixed gas flow of 3 L/min. The airway pressure at which an audible leak occurs around the device (or the pressure at which the capnography waveform flattens) is recorded as the OLP in cm H₂O. Higher OLP indicates a better seal and is considered a better outcome (more effective supraglottic airway seal). The primary metric reported will be the mean (or median) OLP with standard deviation or interquartile range.
Immediately after successful SaCoVLM™ insertion and before start of positive pressure ventilation (measured at a single time point: within 1 minute of confirmation of correct placement)
Proportion of Participants Requiring Any Airway Optimization Maneuver During SaCoVLM™ Placement
時間枠:During the initial airway management procedure, from the start of the first insertion attempt until successful ventilation is confirmed (assessed up to 120 seconds or a maximum of 3 attempts).
The airway optimization protocol includes predefined maneuvers to improve ventilation or seal when SaCoVLM™ placement is suboptimal (e.g., audible leak >30 cm H₂O, absent capnography, or inability to ventilate). Recorded maneuvers may include: chin lift, jaw thrust, head extension/flexion, device rotation, partial withdrawal and reinsertion, or changing to a different size/type of supraglottic airway. The primary outcome metric is the proportion of participants requiring any optimization maneuver during the specified time frame. Secondary metrics include the number of different maneuvers used per participant and the specific maneuvers most frequently applied. No numerical scale is used; this is a descriptive/binary outcome (optimization required: yes/no). Fewer required maneuvers indicate a better outcome (easier device placement).
During the initial airway management procedure, from the start of the first insertion attempt until successful ventilation is confirmed (assessed up to 120 seconds or a maximum of 3 attempts).
Incidence and Severity of Postoperative Sore Throat (POST) as Assessed by a 4-Point Scale
時間枠:At 72 hours after the end of surgery

POST is measured using a 4-point categorical scale:

0 = no sore throat

  1. = mild sore throat (complains only when asked)
  2. = moderate sore throat (complains spontaneously)
  3. = severe sore throat (hoarseness or difficulty swallowing) Minimum value = 0, maximum value = 3. Higher scores indicate a worse outcome (more severe sore throat).

The primary metrics reported will be:

Incidence = proportion of participants with any POST (score ≥1) at the specified time point Severity = mean (or median) score at each time point, plus the proportion with severe POST (score 3)

At 72 hours after the end of surgery
Incidence and Severity of Postoperative Hoarseness as Assessed by a 4-Point Scale
時間枠:At 24 hours after the end of surgery

Postoperative hoarseness is measured using a 4-point categorical scale:

0 = no hoarseness (voice normal)

  1. = mild hoarseness (voice slightly different but able to speak without difficulty)
  2. = moderate hoarseness (voice obviously changed, speaking with effort)
  3. = severe hoarseness (voice barely audible or aphonic)
At 24 hours after the end of surgery
Number of Participants with Treatment-Emergent Adverse Events (TEAEs)
時間枠:From the end of surgery until 72 hours postoperatively
Adverse events (AEs) are defined according to [specify system, e.g., Common Terminology Criteria for Adverse Events (CTCAE) version 5.0 or a standardized surgical complication list]. AEs include, but are not limited to: hypoxia, bradycardia, hypotension, laryngospasm, bronchospasm, dental trauma, bleeding, and allergic reaction. Each AE is graded for severity (mild/moderate/severe) and relationship to the procedure. The primary metric reported will be the proportion of participants experiencing at least one AE during the specified time frame. Secondary metrics include the total number of AEs, type and frequency of specific AEs, and proportion of severe AEs. No scale is used for the primary binary outcome; severity grading follows CTCAE (Grade 1-5, where higher grade = worse outcome).
From the end of surgery until 72 hours postoperatively

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Yongtao Sun、Shandong First medical university
  • スタディチェア:Min Zhang、Shandong First medical university

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2022年5月1日

一次修了 (実際)

2023年5月20日

研究の完了 (実際)

2023年5月30日

試験登録日

最初に提出

2026年4月6日

QC基準を満たした最初の提出物

2026年5月1日

最初の投稿 (実際)

2026年5月7日

学習記録の更新

投稿された最後の更新 (実際)

2026年5月7日

QC基準を満たした最後の更新が送信されました

2026年5月1日

最終確認日

2026年5月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • YXLL-KY-2022 035
  • 320.6750.2024-15-19 (その他の助成金/資金番号:Wu Jie-ping Medical Foundation)

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

はい

IPD プランの説明

all IPD collected throughout the trial, only IPD used in the results publication

IPD 共有時間枠

From May 2022 to May 2023, we included a total of 57 patients who were scheduled to undergo bariatric surgery.

IPD 共有アクセス基準

Who Qualified researchers from academic, non-profit, or commercial institutions with an approved research proposal; regulatory authorities; and direct collaborators.

What Anonymized IPD, data dictionary, protocol, SAP, and ICF summary. No direct or indirect participant identifiers.

How

Submit proposal via online portal.

Independent review committee approval.

Sign data use agreement (non-identification, non-commercial, no third-party sharing).

Access via secure virtual research environment or encrypted download; time-limited (e.g., 12 months); audit logs kept.

IPD 共有サポート情報タイプ

  • STUDY_PROTOCOL
  • SAP
  • ICF
  • ANALYTIC_CODE
  • CSR

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ