Lumbar puncture (LP) is a frequently performed procedure in pediatric emergency departments, most often to evaluate meningitis in hyperthermic, hypothermic, or ill-appearing neonates, infants and children. Older children often present with headaches, meningismus, and/or altered mental status.
The risks of LP include introduction of pathogens, pain, the need for multiple attempts, and failure to obtain interpretable CSF. The latter frequently leads to a spine ultrasound study the following day and, if this does not demonstrate an epidural blood clot, repeat lumbar puncture using fluoroscopic guidance by interventional radiologists.
In evaluating the management of infant sepsis, one study found that the success of the initial LP plays a significant role: infants with unsuccessful initial LPs have longer hospital stays and require more resources. Therefore, ensuring successful LPs on the first attempt is critical for minimizing healthcare utilization, optimizing patient care, and decreasing the emotional burden of this procedure on parents and patients.
Unfortunately, epidural hematoma (EDH) is not uncommon after LP, with U/S diagnosed EDH identified among 40% of patients < 6 months with a traumatic LP and among 31% of unsuccessful but nontraumatic LP's, with complete effacement of the thecal sac in 17%. The spinal canal is wide enough to accommodate EDH with only rare sequelae. However, intramedullary hemorrhage of the conus medullaris resulting in paraplegia in a neonate has been reported.
Since the introduction of the revised febrile neonate guidelines in 2021,4 the number of lumbar punctures performed in young infants has decreased substantially. A consequence of performing fewer lumbar punctures is that clinicians-particularly trainees and early-career practitioners-have fewer opportunities to maintain procedural competence. As procedural skill and confidence decline, the risk of obtaining non-interpretable or traumatic samples increases.
Clearly, improvement of the traditional approach to LP in neonates and infants and young children is needed to prevent these complications. Ultrasound is an imaging modality that is frequently used in the emergency department and does not involve ionizing radiation. Ultrasound can be used prior to lumbar punctures to identify critical anatomical landmarks and needle-insertion distances to avoid the posterior epidural venous plexus and to increase the proportion of LP's with non-traumatic, interpretable CSF. However, an ultrasound technique that is easily learned and that can be applied accurately and efficiently in the emergency department is lacking. Incorporating ultrasound (U/S) into LP training or performance may help clinicians who perform the procedure infrequently to improve success rates and obtain interpretable cerebrospinal fluid samples through identifying optimal intervertebral spaces, visualizing spinal anatomy, and guiding needle placement.
This study employs a standardized, ultrasound-assisted LP approach that integrates pre-procedural identification of spinal anatomy and measurement of the optimal needle insertion distance along the angled trajectory to potentially minimize traumatic taps. Unlike traditional LP methods, this approach provides objective, reproducible guidance that can be given and applied by clinicians. The study is novel in its prospective assessment of ultrasound-guided LP outcomes. By evaluating interpretable CSF yield, this research advances pediatric procedural methodology and has the potential to establish a new standard of care for LP in young infants.
The overarching aim of this research is to determine whether U/S-assisted LP increases the rate of interpretable CSF from the current, approximately 65% to at least 80%.
Primary Aim: To determine the extent to which ultrasound-assisted lumbar puncture using a standardized procedure, including use of ultrasound to ascertain the presence of cerebrospinal fluid (CSF) at L3 - L5 and the optimal needle insertion distance, increases the acquisition rate of CSF that is interpretable for patient management.
Hypothesis: The standardized, ultrasound-assisted procedure for lumbar puncture in neonates and infants is associated with yield of interpretable CSF of at least 85%.
A Sufficient U/S study includes visualization of the following with each reported by the proceduralist on the data report form:
- Lower lumbar and S1 spinous processes visualized
- S1 drop-off
- L4-5 and/or L3-5 interspaces visualized
- Presence of CSF sufficient for LP
- Cauda Equina
Inclusion of lumbar punctures for which U/S was not performed:
We will review and record the results of studies performed without U/S guidance, the technique used by clinicians not participating in this study provide a prospectively acquired control group with which to compare outcomes after U/S measurement. This data will be used in the multivariable regression models described below.
Use of Previously Obtained Ultrasound Images:
As part of this study, investigators may utilize ultrasound images that were obtained as part of routine clinical care prior to the performance of lumbar puncture. These ultrasound images will have been acquired independently of, and prior to, study enrollment and will not require any additional imaging procedures for research purposes. When used for research analysis, ultrasound images will be limited to those relevant to the study objectives. Images will be accessed only by authorized study personnel and will be de-identified prior to analysis whenever feasible. No additional risk to participants is anticipated as a result of using these previously obtained clinical images.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Donald H Arnold, MD, MPH
- 電話番号:615-936-4498
- メール:don.arnold@vumc.org
研究場所
-
-
Tennessee
-
Nashville、Tennessee、アメリカ、37232
- 募集
- Vanderbilt University Medical Center
-
コンタクト:
- Donald H Arnold, MD, MPH
- 電話番号:615-936-4498
- メール:don.arnold@vumc.org
-
コンタクト:
-
-
参加基準
適格基準
就学可能な年齢
- 子
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- - Neonates and infants (< 12 months)
- Hemodynamically stable
- Undergoing a lumbar puncture for diagnostic testing
Exclusion Criteria:
- - Infants > 12 months and 1 day
- Signs of clinical instability
- Known spinal anomalies (e.g., spina bifida, meningomyelocele) or previous spinal surgery
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:非ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Ultrasound
Intervention: Ultrasound of spinal canal
|
Ultrasound of spinal canal without contrast.
We included the term "ultrasound contrast" because the choices were limited.
|
|
介入なし:Control Group
Infants undergoing lumbar puncture without ultrasound assist
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Successful LP rate
時間枠:Time from lumbar puncture to results of CSF returned by lab, approximately 1 hour.
|
Acquisition of CSF sufficient for cell count, culture and meningoencephalitis PCR panel (MEP).
|
Time from lumbar puncture to results of CSF returned by lab, approximately 1 hour.
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Unsuccessful ultrasound attempt
時間枠:Immediately after intervention
|
Ultrasound attempt in which the ultrasound operator could not complete the study and, as a result, did not attempt to use ultrasound images to inform LP.
Potential causes include but are not limited to infant fussiness, inability to maintain positioning sufficient for ultrasound, and malfunction of the ultrasound machine.
|
Immediately after intervention
|
|
Traumatic LP rate
時間枠:Time from lumbar puncture to results of CSF returned by lab, approximately 1 hour
|
CSF RBC count > 500 cells/mm, the most widely accepted definition of traumatic LP. 10-12 The rate of traumatic LPs using this definition is 35 - 47% in neonates and 22 - 26% in infants (< 13 months).
|
Time from lumbar puncture to results of CSF returned by lab, approximately 1 hour
|
|
Number of attempts/ Number of Fluoroscopy-guided lumbar puncture (LP)
時間枠:Immediately after intervention
|
Number of attempts required for CSF acquisition or need for fluoroscopy-guided LP
|
Immediately after intervention
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- IRB #251901 HELP Study
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。