このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Augmented Reality in Surgery (ARS)

2026年6月3日 更新者:I.R.C.C.S Ospedale Galeazzi-Sant'Ambrogio

Artificial Intelligence-Based Identification of the Target Zone on Arthroscopic Images During Knee Anterior Cruciate Ligament Reconstruction: An Observational Study

The goal of this observational study is to learn whether an artificial-intelligence software can reliably recognise the anatomical landmarks used to guide femoral bone tunnel placement on the arthroscopic monitor image during anterior cruciate ligament (ACL) reconstruction in adults. The main questions it aims to answer are:

Can the software automatically tell when the arthroscopic image is clean enough to allow identification of these landmarks? Can the software accurately outline the key bony and cartilaginous landmarks on the femur that guide correct tunnel positioning?

Participants will undergo their clinically indicated ACL reconstruction without modifications: short video sequences of the operative field will be recorded from the arthroscopic camera already used in routine practice, and used to train and validate the algorithms. No additional devices, manoeuvres or operative time are required.

調査の概要

詳細な説明

Background and rationale. Anterior cruciate ligament (ACL) reconstruction is one of the most frequently performed orthopaedic procedures worldwide. A well-documented determinant of long-term clinical outcome is the anatomical accuracy of femoral bone tunnel placement, whose centre must reproduce the native ACL footprint on the lateral wall of the intercondylar notch. Femoral tunnel malposition is recognised in the literature as a contributing factor to recurrent instability, graft failure and revision surgery. Anatomic tunnel placement is guided arthroscopically by the visual identification of bony and cartilaginous landmarks - most notably the resident's ridge (lateral intercondylar ridge) and the posterior cartilaginous margin of the lateral femoral condyle. These landmarks must be discriminated from the surrounding tissue on the 2D arthroscopic monitor image; their identification depends on operator experience and on the quality of the visual field, which can be degraded by soft-tissue debris, bleeding or suboptimal camera orientation. The reported association between surgeon case volume and surgical outcome reflects, in part, the learning curve associated with this visual task. Computer vision and artificial intelligence methods applied to surgical video offer a route to automated, reproducible recognition of these landmarks on the existing arthroscopic image stream, without modifying the hardware already present in the operating room.

Investigational system. The ARS (Augmented Reality in Surgery) software pipeline analyses arthroscopic video acquired from the standard arthroscopic camera column. Two functional modules are evaluated: a binary classifier that determines whether the field of view is sufficiently free of debris and adequately oriented to allow landmark identification, and a semantic segmentation module that delineates the resident's ridge, the posterior cartilaginous margin of the lateral femoral condyle and the candidate anatomical footprint zone for femoral tunnel placement. The algorithmic core is built by fine-tuning surgical vision foundation models on a dataset specifically curated for this task. The intended future deployment paradigm - outside the scope of the present study - is an unobtrusive visual overlay on the existing arthroscopic monitor, supporting the surgeon's visual interpretation. By design, the system is a decision-support tool: it does not pilot instruments, does not take autonomous decisions, and does not substitute the surgeon's judgement at any step of the procedure.

Study design. The study is a prospective, single-centre observational study conducted at IRCCS Galeazzi-Sant'Ambrogio (Milan, Italy). A retrospective component, based on previously acquired arthroscopic video material from ACL reconstructions performed within the same Unit and managed under applicable data-protection and consent provisions, is used for additional independent validation of the algorithms. The prospective component is fully integrated into the standard clinical pathway: no additional surgical step, device or instrument is introduced, no operative time is added, and the system is not used to guide any intraoperative decision during enrolment. The algorithm operates offline on the recorded material.

Video acquisition protocol. For each enrolled patient, six 5-second video segments are extracted from a single continuous intra-operative recording captured from the existing arthroscopic camera column at native 1920×1080 resolution and 60 frames per second. Five segments document the state of the intercondylar notch at progressive cleaning steps - corresponding to approximately 0%, 25%, 50%, 75% and 100% completion of soft-tissue debridement of the lateral wall - and the sixth segment is acquired with the surgical probe positioned on the posterior cartilaginous margin, without occluding the candidate footprint zone, in order to capture the instrument-anatomy spatial relationship in the same anatomical frame. During the procedure the surgeon verbally announces each stability moment to facilitate post-operative segment extraction. Cleaning of the lateral wall in the resident's ridge region is performed exclusively with radiofrequency ablation; motorised instrumentation is avoided in this region during enrolment to preserve the integrity of the bony ridge as a visual landmark.

Data management. Footage is pseudonymised at the point of acquisition; only intra-articular content is recorded, and no patient-identifying frames are produced. A structured naming convention is applied at ingestion. All study data are stored on institutional infrastructure under the governance of IRCCS Galeazzi-Sant'Ambrogio, processed in accordance with Regulation (EU) 2016/679 (GDPR) and applicable Italian implementing legislation. Each video segment is traceable to a single enrolment record on the institutional study management system, supporting source-data verification.

Annotation workflow. Annotation is performed on a self-hosted instance of the CVAT Community Edition platform, deployed on institutional infrastructure. Three annotation workstreams are configured: a field-classification workstream, in which each segment is assigned a class corresponding to the cleaning step; an anatomical-segmentation workstream, in which every extracted frame of the fully-cleaned segment is densely annotated with polyline labels for the resident's ridge and the posterior cartilaginous margin and with a polygon label for the candidate perforation zone; and an instrument-plus-anatomy workstream addressing the segment recorded with the surgical probe in position. An AI-collaborative labelling pipeline is employed, in which a vision foundation model generates mask proposals that the expert surgeon annotator subsequently refines. The reference standard is established by a senior surgeon with sub-specialty expertise in knee arthroscopy; a subset of cases is independently re-annotated to estimate inter-rater agreement, and discrepancies are adjudicated by consensus.

Algorithm training and performance assessment. Models are trained on the annotated prospective dataset, supplemented by the retrospective material where applicable, and evaluated on a held-out subset. Algorithm performance is summarised by classification accuracy, sensitivity, specificity and F1 score for the field-quality classifier, and by intersection-over-union (IoU) and Dice similarity coefficient at the per-frame level for the anatomical-segmentation outputs, reported with bootstrap confidence intervals. Pre-specified sensitivity analyses include stratification by cleaning step, by camera orientation and by surgical phase.

Quality assurance. Standard Operating Procedures cover video acquisition, file management and annotation. Each procedure is version-controlled and distributed to all study personnel. Automated data validation rules check naming-convention compliance, segment duration, resolution and frame rate at ingestion. Video segments failing technical quality checks - for example, due to excessive motion blur or to instrument occlusion of the candidate footprint zone in segments where the instrument should not be present - are excluded from the analysis dataset, and exclusions are documented at segment level. Adverse events are not anticipated as a direct consequence of the observational procedure; any clinical event occurring during the standard ACL reconstruction is documented in the institutional clinical record according to routine practice and is not part of the study endpoints.

Sample size and missing data. The required sample size is driven by the technical objective of training and validating image-analysis algorithms rather than by a clinical-effect estimate, and is specified in the study protocol. Handling of missing data and the segment-level exclusion criteria for technical inadequacy are pre-defined in the analysis plan.

Statistical analysis. The statistical analysis plan is developed in collaboration with an institutional biostatistician and is documented in the study protocol. Algorithm performance metrics are reported as point estimates with bootstrap confidence intervals; comparisons across strata, where applicable, use non-parametric tests appropriate to the per-frame or per-patient unit of analysis.

Regulatory positioning. The investigational software is used in this study under a research protocol and is not employed to guide intraoperative decisions during enrolment. Any future clinical deployment is anticipated under the European Medical Device Regulation framework as a decision-support software intended to assist the surgeon's visual interpretation, without autonomous guidance.

Ethics. The study is conducted in accordance with the Declaration of Helsinki, with applicable European and Italian regulations on observational research with health data, and with Regulation (EU) 2016/679 (GDPR). Approval by the competent Ethics Committee is obtained prior to study initiation.

研究の種類

観察的

入学 (推定)

100

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

    • Michigan
      • Milan、Michigan、イタリア、20157
        • 募集
        • IRCCS Ospedale Galeazzi-Sant'Ambrogio
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

確率サンプル

調査対象母集団

Patients referred to and treated at the Knee Surgery and Sports Traumatology Unit of IRCCS Galeazzi-Sant'Ambrogio in Milan, Italy. The institution is a tertiary orthopaedic referral hospital and a recognised Italian Scientific Hospital for Research and Care (Istituto di Ricovero e Cura a Carattere Scientifico), dedicated to the musculoskeletal system and performing a very high yearly volume of orthopaedic procedures. Within the institution, the Knee Surgery and Sports Traumatology Unit is a homogeneous surgical team with a substantial annual caseload of arthroscopic anterior cruciate ligament reconstructions. Enrolment is single-centre, prospective and consecutive across the study period.

説明

Inclusion Criteria:

  • Age 18 years or older
  • Scheduled for primary arthroscopic anterior cruciate ligament reconstruction at IRCCS Galeazzi-Sant'Ambrogio
  • Signed written informed consent

Exclusion Criteria:

  • Revision anterior cruciate ligament reconstruction
  • Arthroscopic video quality judged inadequate by the investigator (artefacts, insufficient illumination, uninterpretable images)
  • Failure to sign informed consent, or withdrawal of consent

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Adult patients undergoing primary arthroscopic ACL reconstruction
Adult patients (age 18 years or older) consecutively enrolled at IRCCS Galeazzi-Sant'Ambrogio (Milan, Italy) for primary arthroscopic anterior cruciate ligament reconstruction. The procedure follows the institutional standard of care; no investigational device, additional intraoperative manoeuvre or operative-time extension is introduced for study purposes. During surgery, a continuous arthroscopic video is recorded from the standard arthroscopic camera column already in clinical use, and short segments are extracted to document the lateral wall of the intercondylar notch at progressive cleaning steps and the instrument-anatomy relationship at the fully-cleaned step. The recorded material is pseudonymised and used to train and validate computer vision algorithms for landmark identification on the arthroscopic image. The first 50 enrolled subjects contribute to algorithm training; the subsequent 50 to independent validation.
Arthroscopic reconstruction of the anterior cruciate ligament performed per institutional surgical protocol. Cleaning of the lateral wall of the intercondylar notch in the resident's ridge region uses exclusively radiofrequency ablation; motorised instrumentation is avoided in this region to preserve the integrity of the bony landmark. Per enrolled patient, a continuous intra-operative recording is obtained from the unmodified standard arthroscopic camera column at 1920x1080 resolution and 60 fps; six 5-second segments are extracted, five documenting progressive cleaning steps of the lateral wall (0%, 25%, 50%, 75%, 100% completion) and one acquired with the surgical probe positioned on the posterior cartilaginous margin without occluding the candidate femoral footprint zone. The investigational software is not used to guide any intraoperative decision during enrolment; the algorithm operates offline on the recorded material.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Area Under the Receiver Operating Characteristic Curve (AUC-ROC) of the binary classification of arthroscopic field cleanliness
時間枠:Through study completion, an average of 12 months
Area under the receiver operating characteristic curve (AUC-ROC) of the deep learning model trained to perform binary classification of arthroscopic frames into "fully cleaned" (corresponding to 100% completion of soft-tissue debridement of the lateral wall of the intercondylar notch) versus "not fully cleaned" (corresponding to 0%, 25%, 50% and 75% completion). AUC-ROC is computed on the independent validation cohort (frames extracted from the second 50 subjects, not used during training), with 95% confidence interval estimated by bootstrap. Additional descriptive performance metrics - overall classification accuracy, sensitivity, specificity, positive predictive value and F1-score - are pre-specified in the study protocol and reported as supportive.
Through study completion, an average of 12 months

二次結果の測定

結果測定
メジャーの説明
時間枠
Mean Dice similarity coefficient of the semantic segmentation of anatomical landmarks on arthroscopic frames
時間枠:Through study completion, an average of 12 months
Mean Dice similarity coefficient (Sorensen-Dice coefficient) at the per-frame level for the deep learning model trained to perform semantic segmentation of anatomical landmarks on arthroscopic frames acquired at full cleaning of the lateral wall of the intercondylar notch. The segmentation targets are the resident's ridge area (bony landmark) and the candidate perforation zone for femoral tunnel placement. The Dice coefficient is computed on the independent validation cohort (frames extracted from the second 50 subjects, not used during training), with 95% confidence interval estimated by bootstrap. Additional descriptive performance metrics - Intersection over Union, pixel accuracy and mean pixel accuracy per class - are pre-specified in the study protocol and reported as supportive.
Through study completion, an average of 12 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年5月26日

一次修了 (推定)

2026年12月31日

研究の完了 (推定)

2027年5月31日

試験登録日

最初に提出

2026年5月23日

QC基準を満たした最初の提出物

2026年6月3日

最初の投稿 (実際)

2026年6月9日

学習記録の更新

投稿された最後の更新 (実際)

2026年6月9日

QC基準を満たした最後の更新が送信されました

2026年6月3日

最終確認日

2026年6月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

The arthroscopic video material and derived annotations collected in this study are owned by IRCCS Galeazzi-Sant'Ambrogio, which acts as data controller, in accordance with institutional research and intellectual property policy and with applicable data protection legislation. The data constitute an institutional research asset and contain sensitive surgical material that, although pseudonymised at the point of acquisition, requires controlled access to ensure compliance with data protection obligations and to safeguard the legitimate interests of the data controller. Any future external access or transfer would require explicit authorisation by the institution and would be governed by a dedicated data access agreement and, where applicable, by additional ethical review. At the time of registration, no individual participant data sharing plan with external researchers is in place.

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する