このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Buccal Prosthetic Contour Angles and Peri-Implant Tissue Changes Around Dental Implants (B-PROFILE)

2026年6月4日 更新者:Chang Gung Memorial Hospital

Association Between Buccal Prosthetic Profile Angles at Different Supraplatform Zones and Peri-Implant Tissue Remodeling Around Bone-Level Implants: A Retrospective CBCT-Based Cohort Study

This retrospective observational study aims to evaluate the association between buccal prosthetic profile angles at different supraplatform zones and peri-implant tissue changes around bone-level dental implants restored with customized abutments and crowns. The main questions it aims to answer are:

Whether prosthetic profile angles within different vertical zones above the implant platform (0-2 mm and 2-4 mm) demonstrate different associations with marginal bone level changes around dental implants.

Whether buccal prosthetic contour angles at different supraplatform depths are associated with peri-implant soft tissue conditions, including keratinized tissue width and mucosal changes.

Whether peri-implant phenotype-related factors, including mucosal tunnel depth, soft tissue thickness, and buccal bone thickness, are associated with peri-implant tissue remodeling.

Researchers will retrospectively analyze clinical records, intraoral photographs, radiographic images, and cone-beam computed tomography (CBCT) scans collected during routine implant treatment and follow-up care up to 1 year after prosthetic loading. Buccal prosthetic contour angles will be measured at different vertical zones above the implant platform to evaluate the biologic influence of contour configuration at different peri-implant tissue levels.

調査の概要

詳細な説明

This retrospective observational cohort study aims to evaluate the association between buccal prosthetic profile angles at different supraplatform vertical zones and peri-implant tissue remodeling around bone-level dental implants restored with customized abutments and crowns. Although prosthetic emergence profile and contour configuration have been associated with peri-implant biologic complications, limited evidence is available regarding the biologic influence of different buccal contour zones above the implant platform, particularly within the esthetic region. Existing studies have mainly focused on interproximal restorative contours, while the influence of buccal contour configuration at different vertical levels on peri-implant hard and soft tissue conditions remains unclear.

This study will retrospectively analyze patients restored with screw-retained or screwmentable implant-supported prostheses with customized abutments and at least 1 year of follow-up after prosthetic loading. Clinical records, intraoral photographs, radiographic images, and cone-beam computed tomography (CBCT) scans obtained during routine implant treatment and maintenance will be reviewed.

The primary objective is to evaluate whether buccal prosthetic profile angles measured at different vertical supraplatform zones demonstrate different associations with peri-implant marginal bone level changes. Buccal contour-related angles will include the overall buccal emergence angle, the buccal profile angle measured within 0-2 mm above the implant platform, and the buccal profile angle measured within 2-4 mm above the implant platform. These measurements are intended to investigate whether different peri-implant tissue levels demonstrate different biologic responses to prosthetic contour configuration.

Secondary objectives include evaluation of the association between prosthetic contour variables and peri-implant soft tissue conditions, including keratinized mucosa width (KMW), mucosal margin changes, probing depth, bleeding on probing, mucosal tunnel depth, and peri-implant soft tissue thickness. Additional peri-implant phenotype-related variables, including buccal bone thickness, implant placement depth, and soft tissue augmentation procedures, will also be analyzed for their potential association with peri-implant tissue remodeling.

Marginal bone level changes and peri-implant tissue conditions will be evaluated using clinical measurements, standardized intraoral photographs, vertical bitewing radiographs, and CBCT images obtained during routine follow-up care. CBCT analysis will be performed at 1 year after prosthetic loading to evaluate three-dimensional peri-implant bone morphology and prosthetic contour configuration.

Statistical analyses will include descriptive statistics and normality assessment. Depending on data distribution, Mann-Whitney U tests or Kruskal-Wallis tests may be used for supportive group comparisons when appropriate. Associations between peri-implant tissue changes and prosthetic contour variables will primarily be evaluated using univariable and multivariable linear regression analyses. Interaction analyses will also be performed to evaluate whether peri-implant phenotype-related variables modify the association between prosthetic contour angles and marginal bone level changes. Segmented regression analysis will additionally be performed to explore potential threshold effects associated with peri-implant tissue remodeling. All statistical tests will be two-sided with a significance level of α = 0.05.

The planned sample size is approximately 100 implant sites with complete clinical and radiographic follow-up records. Only cases with complete imaging quality and adequate follow-up documentation will be included in the final analysis. Missing or incomplete records, radiographic artifacts, severe image distortion, or inadequate maintenance follow-up will lead to exclusion from analysis.

研究の種類

観察的

入学 (推定)

100

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Taipei、台湾
        • Chang Gung Memorial Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

非確率サンプル

調査対象母集団

Adult patients receiving bone-level dental implant treatment with customized abutments and screw-retained or screwmentable prosthetic restorations at Chang Gung Memorial Hospital will be retrospectively included. Eligible participants will have completed two-stage implant surgery, prosthetic rehabilitation, and routine maintenance follow-up with available clinical records, intraoral photographs, radiographic examinations, and cone-beam computed tomography (CBCT) scans for at least 1 year after prosthetic loading. Implant placement, peri-implant soft tissue management, and follow-up procedures were performed under standardized clinical protocols by the same experienced clinician to minimize procedural variability. Patients with inadequate imaging quality, incomplete follow-up records, peri-implant bone dehiscence after implant placement, or systemic conditions affecting healing will be excluded.

説明

Inclusion Criteria:

  • Adults aged 20 years or older.
  • Patients receiving at least one bone-level dental implant restored with a customized abutment and screw-retained or screwmentable prosthesis.
  • Presence of at least one adjacent natural tooth and an opposing dentition.
  • Implant sites that received second-stage surgery and prosthetic restoration.
  • Presence of at least 2 mm of peri-implant keratinized mucosa after second-stage surgery.
  • No buccal or peri-implant bone dehiscence following implant placement.
  • Availability of complete clinical records, intraoral photographs, radiographic images, and cone-beam computed tomography (CBCT) scans with at least 1 year of follow-up after prosthetic loading.

Availability of adequate radiographic quality for peri-implant hard and soft tissue measurements.

Exclusion Criteria:

  • Uncontrolled systemic diseases or medical conditions that may affect healing, including uncontrolled diabetes mellitus, metabolic bone diseases, autoimmune diseases, or history of head and neck radiotherapy.
  • Current use of medications known to affect bone metabolism.
  • Pregnancy, planned pregnancy, or breastfeeding.
  • Poor-quality CBCT images or radiographic artifacts that interfere with measurement accuracy.
  • Incomplete clinical or radiographic follow-up records.
  • Poor oral hygiene or irregular supportive maintenance follow-up.
  • Implant sites with prosthetic or imaging conditions preventing reliable evaluation of prosthetic contour configuration or peri-implant tissue measurements.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Bone-Level Implant Cohort
Participants receiving bone-level dental implants restored with customized abutments and screw-retained or screwmentable prostheses with available longitudinal clinical and radiographic follow-up data for at least 1 year after prosthetic loading. Clinical records, intraoral photographs, vertical bitewing radiographs, and cone-beam computed tomography (CBCT) scans obtained during routine implant treatment and maintenance care will be retrospectively analyzed to evaluate the association between buccal prosthetic profile angles at different supraplatform zones and peri-implant hard and soft tissue remodeling. Peri-implant phenotype-related variables, including mucosal tunnel depth, soft tissue thickness, keratinized mucosa width, and buccal bone thickness, will also be evaluated.
Participants included in this retrospective observational cohort study received routine implant-supported prosthetic rehabilitation with bone-level dental implants restored using customized abutments and screw-retained or screwmentable prostheses. Prosthetic contour configuration and buccal profile angles at different supraplatform vertical zones (overall emergence angle, 0-2 mm profile angle, and 2-4 mm profile angle above the implant platform) will be evaluated using cone-beam computed tomography (CBCT) and radiographic analysis. Clinical and radiographic follow-up data obtained during routine maintenance care up to 1 year after prosthetic loading will be retrospectively analyzed to assess associations between prosthetic contour characteristics and peri-implant hard and soft tissue remodeling.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Marginal Bone Level Change
時間枠:Baseline(implant placement) to 1 year after prosthetic loading
Change in peri-implant marginal bone level associated with buccal prosthetic profile angles measured at different supraplatform vertical zones (overall emergence angle, 0-2 mm profile angle, and 2-4 mm profile angle above the implant platform), evaluated using radiographic and cone-beam computed tomography (CBCT) analysis.
Baseline(implant placement) to 1 year after prosthetic loading

二次結果の測定

結果測定
メジャーの説明
時間枠
Keratinized Mucosa Width (KMW) Change
時間枠:Baseline to 1 year after prosthetic loading
Change in peri-implant keratinized mucosa width associated with buccal prosthetic profile angles at different supraplatform vertical zones.
Baseline to 1 year after prosthetic loading
Buccal Bone Thickness
時間枠:1 year after prosthetic loading
Buccal peri-implant bone thickness evaluated on CBCT images at 1 year after prosthetic loading.
1 year after prosthetic loading
Mucosal Tunnel Depth
時間枠:Baseline (at prosthetic loading)
Clinical mucosal tunnel depth associated with prosthetic contour configuration and peri-implant tissue remodeling.
Baseline (at prosthetic loading)
Probing depth change
時間枠:Baseline to 1 year after prosthetic loading
Change in peri-implant probing depth associated with buccal prosthetic profile angle.
Baseline to 1 year after prosthetic loading

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Cho-Ying Lin、Chang Gung Memorial Hospital

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2019年11月13日

一次修了 (実際)

2025年10月16日

研究の完了 (推定)

2026年7月31日

試験登録日

最初に提出

2026年5月21日

QC基準を満たした最初の提出物

2026年6月4日

最初の投稿 (実際)

2026年6月10日

学習記録の更新

投稿された最後の更新 (実際)

2026年6月10日

QC基準を満たした最後の更新が送信されました

2026年6月4日

最終確認日

2026年2月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

Individual participant data will not be publicly available because of privacy and institutional data protection restrictions.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する