このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

NIR Device for Assessment of Skin Flap Perfusion in Breast Surgery: A Pilot Interventional Study (ADisIRast)

2026年6月29日 更新者:Valentina Hartwig、National Research Council, Institute of Clinical Physiology, Italy

ADisIRast: Applicazione Del Dispositivo NIR Nella Breast Unit. Studio Pilota Monocentrico, Non Randomizzato, Interventistico Con Dispositivo Medico, Premarket, Non Profit, Per la Valutazione Della Perfusione Del Lembo Cutaneo Pre e Post Operatoria

The goal of this single-center, nonrandomized, interventional non-profit pilot study is to evaluate the feasibility and clinical utility of a non-invasive near-infrared spectroscopy (NIRS) imaging device for assessing skin-flap tissue oxygen saturation in adult women undergoing mastectomy and immediate breast reconstruction after oncological surgery.

The main questions it aims to answer are:

  • Can NIRS imaging provide reproducible measurements of tissue oxygen saturation (StO₂) in mastectomy skin flaps before surgery, during the intraoperative phase, and during postoperative follow-up?
  • Can spatial and temporal variations in StO₂ identify areas of potentially reduced flap perfusion or impaired tissue viability?
  • Can NIRS-derived oxygenation measurements support the assessment of postoperative flap healing and ischemic complications?

Participants will:

  • undergo non-invasive NIRS imaging of the breast skin flap before surgery;
  • undergo one intraoperative NIRS acquisition during mastectomy and immediate breast reconstruction;
  • undergo repeated NIRS imaging during postoperative follow-up visits;
  • receive standard surgical treatment and postoperative care according to routine clinical practice.

NIRS imaging is performed for study purposes and does not influence intraoperative surgical decision-making or the choice of reconstructive procedure.

調査の概要

詳細な説明

The ADISIRAST study is a single-center, non-randomized, pre-market, non-profit clinical investigation of a non-invasive near-infrared spectroscopy (NIRS) imaging device for the assessment of perfusion in mastectomy skin flaps in patients undergoing breast surgery with immediate reconstruction.

Mastectomy skin-flap viability is an important determinant of postoperative healing and reconstructive outcomes. In routine clinical practice, flap perfusion is mainly assessed through intraoperative inspection and surgical judgment. Objective methods for evaluating tissue oxygenation may provide complementary information and may help characterize regional perfusion patterns that are not readily apparent during standard clinical assessment.

Near-infrared spectroscopy is a non-invasive optical technique that estimates superficial tissue oxygen saturation (StO₂) by analyzing the relative absorption of near-infrared light by oxygenated and deoxygenated hemoglobin. The investigational device is a portable, non-contact NIRS imaging system that generates two-dimensional maps of superficial tissue oxygen saturation. The device does not require tissue contact, contrast-agent injection, or exposure to ionizing radiation. Acquisitions are performed by positioning the device at a standardized distance from the surgical area and obtaining a digital image together with the corresponding StO₂ map.

The study was designed to evaluate the feasibility, repeatability, and clinical interpretability of NIRS-derived StO₂ measurements in breast skin flaps throughout the perioperative period. NIRS images were acquired at predefined study time points, including a preoperative baseline assessment, an intraoperative assessment, and postoperative follow-up assessments(1 day and 15 days postoperative). This approach allowed the characterization of temporal changes in tissue oxygenation and the evaluation of regional differences within the skin flap.

Image analysis included assessment of absolute StO₂ values, regional oxygenation differences, spatial distribution of tissue areas within predefined StO₂ ranges, and longitudinal changes in oxygenation patterns. Regions of interest were defined within superior and inferior portions of the breast skin flap to explore regional perfusion heterogeneity. Additional image-derived metrics were calculated to quantify the extent of tissue area within selected StO₂ ranges and the degree of spatial heterogeneity of oxygenation.

Clinical and surgical data were prospectively collected, including reconstructive information, perioperative characteristics, postoperative flap healing, and clinically observed complications. NIRS findings were subsequently evaluated in relation to postoperative clinical observations, particularly the presence, location, and evolution of areas showing impaired healing or suspected ischemic changes.

Surgical planning and intraoperative decisions, including the choice of reconstructive approach, were made according to standard clinical practice, based on the treating surgical team's clinical assessment and preoperative evaluation. The operating surgeon was blinded to the intraoperative NIRS images, and NIRS findings did not influence surgical decision-making or the selection of the reconstructive procedure.

After study completion, NIRS-derived perfusion findings were retrospectively compared with the reconstructive strategy selected during surgery. This exploratory analysis was performed to assess the concordance between NIRS-based indications of flap perfusion and the clinical decision made by the surgical team. The analysis was intended to explore the potential future role of non-invasive tissue oxygenation imaging as an adjunctive tool for perioperative assessment and surgical training, rather than to evaluate a device-guided management strategy.

The study does not compare alternative surgical treatments or reconstructive techniques. It is designed as a feasibility and performance investigation and is not powered to establish definitive diagnostic thresholds, predict clinical outcomes with definitive accuracy, or demonstrate superiority of one reconstructive strategy over another. Data were collected prospectively and managed using coded participant identifiers.

研究の種類

介入

入学 (実際)

20

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Pisa、イタリア、56126
        • U.O. Senologia, Azienda Ospedaliero-Universitaria Pisana (AOUP) Presidio Ospedaliero Santa Chiara

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • Female sex, aged 18 to 90 years.
  • Breast cancer patients scheduled for mastectomy with immediate reconstruction using an implant or tissue expander; or healthy BRCA mutation carriers scheduled for prophylactic mastectomy.
  • No previous radiotherapy to the chest wall.
  • No previous neoadjuvant chemotherapy.

Exclusion Criteria:

  • Severe psychiatric disorders.
  • Advanced malignancy.
  • Severe aortic stenosis.
  • Obstructive hypertrophic cardiomyopathy.
  • Severe chronic kidney disease.
  • Severe chronic obstructive pulmonary disease.
  • Uncontrolled diabetes mellitus.
  • Advanced peripheral arterial occlusive disease (Leriche-Fontaine class III).
  • Use of benzodiazepines, non-benzodiazepine hypnotics, typical or atypical antipsychotics, antidepressants, or anticonvulsants without a stable dose for at least 4 months.
  • Alcohol, caffeine, or other substance abuse.
  • Inability to reasonably adhere to study procedures.
  • Pregnancy or breastfeeding.
  • Concurrent participation in another clinical trial.
  • Withdrawal of informed consent.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Snapshot NIR Assessment

Each patient enrolled in the study will undergo the standard diagnostic and treatment process.

The only difference compared to patients not enrolled in the study will be the use of the experimental Snapshot NIR V3.0 device during the routine visits scheduled in any case, and in particular:

during the preoperative consultation between the plastic surgeon and the breast surgeon, which must take place within 30 days prior to surgery; during the pre- and post-operative phases; on the first post-operative day during hospitalization; and on the 15th (+/-5 days) post-operative day during one of the routinely scheduled dressing changes.

The Snapshot NIR V3.0 device is used to noninvasively assess superficial breast skin flap tissue oxygenation and perfusion. NIR images and tissue oxygen saturation measurements are acquired preoperatively, early postoperatively, and at a later postoperative assessment.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Tissue Oxygen Saturation (StO₂) Measured by the Snapshot NIR V3.0 Device
時間枠:Baseline (preoperative), postoperative day 1, and postoperative day 15 (±5 days).
Superficial tissue oxygen saturation (StO₂, %) measured using the Snapshot NIR V3.0 imaging device. StO₂ values (%) will be obtained from predefined Regions of Interest (ROIs) identified on exported two-dimensional tissue oxygenation maps. Mean StO₂ (%) and the presence of hypoperfused areas will be evaluated at each scheduled study visit.
Baseline (preoperative), postoperative day 1, and postoperative day 15 (±5 days).
Correlation Between Snapshot NIR Tissue Oxygen Saturation (StO₂) and Clinical Assessment of Breast Skin Flap Perfusion
時間枠:Baseline (preoperative), postoperative day 1, and postoperative day 15 (±5 days).
Correlation between superficial tissue oxygen saturation (StO₂, %) measured using the Snapshot NIR V3.0 device and the clinical assessment of breast skin flap perfusion performed by visual inspection. Clinical assessment findings and StO₂ measurements will be compared for the predefined Regions of Interest (ROIs). The outcome will be expressed as a correlation coefficient between StO₂ (%) measurements and the corresponding clinical assessment.
Baseline (preoperative), postoperative day 1, and postoperative day 15 (±5 days).
Temporal Change in Tissue Oxygen Saturation (StO₂) of Breast Skin Flaps
時間枠:Baseline (preoperative), postoperative day 1, and postoperative day 15 (±5 days).
Change in superficial tissue oxygen saturation (StO₂, %) measured using the Snapshot NIR V3.0 device over time. Serial StO₂ measurements obtained from predefined Regions of Interest (ROIs) will be compared across study visits to evaluate the temporal evolution of tissue perfusion and hypoperfused areas.
Baseline (preoperative), postoperative day 1, and postoperative day 15 (±5 days).

二次結果の測定

結果測定
メジャーの説明
時間枠
Correlation Between Snapshot NIR Tissue Oxygen Saturation (StO₂) and Intraoperative Reconstructive Strategy
時間枠:Intraoperative.
Correlation between tissue oxygen saturation (StO₂, %) measured using the Snapshot NIR V3.0 device and the intraoperative reconstructive strategy selected by the surgeon (prepectoral implant versus subpectoral tissue expander). The outcome will be expressed as the correlation between StO₂ (%) measurements and the selected reconstructive strategy.
Intraoperative.

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Matteo Ghilli, MD、U.O. Senologia, Azienda Ospedaliero-Universitaria Pisana (AOUP)
  • スタディチェア:Valentina Hartwig, PhD、National Research Council, Institute of Clinical Physiology, Italy
  • スタディディレクター:Maria Giovanna Trivella, MD、National Research Council, Institute of Clinical Physiology, Italy

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2024年10月10日

一次修了 (実際)

2026年2月13日

研究の完了 (実際)

2026年2月13日

試験登録日

最初に提出

2026年6月23日

QC基準を満たした最初の提出物

2026年6月29日

最初の投稿 (実際)

2026年7月2日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月2日

QC基準を満たした最後の更新が送信されました

2026年6月29日

最終確認日

2026年6月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • Adisirast
  • IT-24-04-046716 (その他の識別子:European Database on Medical Devices (EUDAMED))

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

IPD will not be shared because participants consented only to aggregated data publication and due to confidentiality and privacy constraints.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する