Artificial Intelligence-Assisted Advanced Analysis of Knee Imaging and Outcome Prediction (AI; R-CNN)
Artificial Intelligence-Assisted Advanced Analysis of Knee Imaging and Outcome Prediction for Ultrasound-Guided Injections
This study aims to develop and validate an artificial intelligence (AI)-assisted platform for musculoskeletal knee ultrasonography and to establish an interpretable prediction model for clinical outcomes following ultrasound-guided injection therapies in patients with degenerative knee disorders. The project seeks to improve the standardization, reproducibility, and clinical utility of knee ultrasound by reducing operator dependency and providing quantitative image analysis and outcome prediction.
The study will be conducted in three phases. First, an AI foundation model for knee ultrasonography will be developed using standardized image acquisition protocols to enable automated localization, segmentation, and quantitative assessment of major anatomical structures, including tendons, ligaments, cartilage, fat pads, and peripheral nerves. Second, supervised machine learning models will be trained to classify normal and pathological ultrasound findings, including common degenerative and inflammatory abnormalities affecting the knee. Third, retrospective and prospective clinical data from approximately 150 patients receiving ultrasound-guided injection therapies will be integrated to develop and validate a predictive model for treatment outcomes using imaging biomarkers and clinical variables. Treatment response will be evaluated using validated patient-reported outcome measures, and explainable AI methods will be applied to improve model interpretability.
The anticipated outcome of this study is the development of a comprehensive AI-assisted knee ultrasound platform that supports standardized image interpretation, quantitative assessment of musculoskeletal pathology, and personalized prediction of treatment response to ultrasound-guided injection therapies in degenerative knee disorders.
調査の概要
状態
詳細な説明
High-resolution musculoskeletal ultrasonography has become a first-line imaging modality because it enables real-time visualization and dynamic assessment with high accessibility and low cost. Nevertheless, ultrasound remains highly operator-dependent, resulting in variability in image acquisition and interpretation, which limits standardization and widespread implementation, particularly for complex joints such as the knee. Building on our established expertise in computational ultrasound and deep-learning-assisted dynamic shoulder analysis, including patented artificial intelligence (AI)-derived quantitative biomarkers, this three-year project aims to develop an AI platform for advanced knee ultrasound analysis and to construct a predictive model for clinical outcomes following ultrasound-guided injections in degenerative knee disorders.
In the first year, we will establish a normative AI foundation model for knee ultrasonography by developing automated localization and multi-structure segmentation of major anatomical components, including tendons, ligaments, cartilage, fat pads, and peripheral nerves. Standardized acquisition protocols will be implemented to ensure consistent image quality. A Faster Region-Based Convolutional Neural Network (Faster R-CNN) framework incorporating ResNet50, a Feature Pyramid Network, and a Region Proposal Network will be used to detect key bony landmarks, followed by a multi-structure segmentation engine and quantitative feature extraction modules (e.g., thickness, surface regularity, and tissue heterogeneity). Segmentation performance will be evaluated using Intersection-over-Union and Dice coefficients, while measurement reliability will be assessed using intraclass correlation coefficients, standard error of measurement, minimal detectable change, and Bland-Altman analyses.
In the second year, the platform will be expanded to differentiate pathological patterns in knee tendons, ligaments, cartilage, and fat pads. Expert clinicians will label each segmented structure as normal or abnormal and further annotate clinically relevant subtypes, such as tendinopathy, calcification, partial or full-thickness tears, synovial hypertrophy or effusion, cartilage wear or exposure, and meniscal degeneration or tear. Supervised learning models will be trained for classification and evaluated using accuracy, precision, recall (sensitivity), and F1-score.
In the third year, we will develop an outcome prediction model for ultrasound-guided injections by integrating retrospective and prospective real-world data from approximately 150 patients receiving common injection therapies, including intra-articular hyaluronic acid, dextrose prolotherapy or platelet-rich plasma, and peripheral nerve-targeted interventions. Treatment success will be defined using validated patient-reported outcome measures, including the Knee Injury and Osteoarthritis Outcome Score and the Patient Acceptable Symptom State, incorporating minimal clinically important difference thresholds. Feature selection methods and cross-validation will be applied to mitigate overfitting. Model performance will be assessed using area under the receiver operating characteristic curve, sensitivity, specificity, accuracy, F1-score, and calibration metrics, with Shapley Additive exPlanations employed to enhance interpretability. External validation will be performed if additional datasets become available.
This project is expected to deliver the first systematic AI-based normative atlas for knee ultrasonography and an interpretable outcome prediction framework, improving diagnostic consistency, reducing operator dependency, and enabling personalized, evidence-informed injection strategies.
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Wei-Ting Wu, MD
- 電話番号:+886223717101
- メール:wwtaustin@yahoo.com.tw
研究場所
-
-
Taiwan
-
Taipei、Taiwan、台湾、108206
- 募集
- National Taiwan University Hospital Beihu Branch
-
コンタクト:
- Wei-Ting Wu, MD
- 電話番号:+886223717101
- メール:wwtaustin@yahoo.com.tw
-
コンタクト:
- Ke-Vin Chang, MD, PhD
- 電話番号:+886223717101
- メール:kvchang011@gmail.com
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
サンプリング方法
調査対象母集団
説明
Objective 1: Development of an AI-Based Normative Model for the Healthy Knee
Inclusion Criteria:
- Clinical diagnosis of healthy adult without major systemic disease
- Age ≥18 years
- Able to understand and follow study instructions
- Ambulatory without walking aids
- No pain in either knee for at least 6 months before enrollment
Exclusion Criteria:
- Previous knee surgery
- Rupture of one or more cruciate ligaments
- Knee injection within the preceding 6 months
- Major trauma involving the knee or periarticular region
- Rheumatic or autoimmune disease
Objective 2: Development of an AI-Based Model for the Identification of Pathological Knee Structures
Inclusion Criteria:
- Clinical diagnosis of radiographic knee osteoarthritis
- Age ≥18 years
- Knee pain in at least one knee during the preceding year
- Medical records confirming knee pain, soreness, or stiffness within 1 month before enrollment
- Radiographic evidence of knee osteoarthritis, defined by at least one of the following:
- Kellgren-Lawrence grade ≥2 on anteroposterior radiographs
- Kellgren-Lawrence grade ≥2 on skyline (patellofemoral) radiographs
- Superior or inferior patellar osteophytes or posterior tibial osteophytes on lateral radiographs
Exclusion Criteria:
- Systemic rheumatic disease (e.g., rheumatoid arthritis or ankylosing spondylitis)
- Malignancy
- Previous major knee trauma (including fracture)
- Previous knee surgery
- Intra-articular corticosteroid injection within the preceding 3 months
Objective 3: Development of an AI-Assisted Predictive Model for Injection Treatment Outcomes
Inclusion Criteria:
- Clinical diagnosis of radiographic knee osteoarthritis requiring ultrasound-guided injection therapy
- Age ≥18 years
- Knee pain in at least one knee during the preceding year
- Medical records confirming knee pain, soreness, or stiffness within 1 month before enrollment
- Radiographic evidence of knee osteoarthritis, defined by at least one of the following:
- Kellgren-Lawrence grade ≥2 on anteroposterior radiographs
- Kellgren-Lawrence grade ≥2 on skyline (patellofemoral) radiographs
- Superior or inferior patellar osteophytes or posterior tibial osteophytes on lateral radiographs
- Willingness to undergo ultrasound-guided injection therapy and complete scheduled follow-up assessments
Exclusion Criteria:
- Systemic rheumatic disease (e.g., rheumatoid arthritis or ankylosing spondylitis)
- Malignancy
- Previous major knee trauma (including fracture)
- Previous knee surgery
- Intra-articular corticosteroid injection within the preceding 3 months
研究計画
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
AI Segmentation Performance for Normal Knee Structures
時間枠:Baseline (at ultrasound examination)
|
Performance of the artificial intelligence model in automatically identifying and segmenting normal knee anatomical structures on ultrasound images.
Model performance will be evaluated using the Dice Similarity Coefficient (DSC) and Intersection-over-Union (IoU) by comparing AI-generated segmentation with expert manual annotations.
Target structures include tendons, ligaments, cartilage, menisci, fat pads, and peripheral nerves.
|
Baseline (at ultrasound examination)
|
|
Diagnostic Accuracy of AI-Based Classification of Knee Pathologies
時間枠:Baseline (at ultrasound examination)
|
Diagnostic performance of the AI model in differentiating normal and pathological knee structures on ultrasound imaging.
Performance will be evaluated using accuracy, sensitivity (recall), specificity, precision, F1-score, and area under the receiver operating characteristic curve (AUC), using expert ultrasound interpretation as the reference standard.
Pathologies include tendinopathy, calcification, ligament sprain or tear, meniscal degeneration or tear, cartilage degeneration, synovitis, fat pad inflammation, and peripheral nerve enlargement.
|
Baseline (at ultrasound examination)
|
|
Accuracy of AI Prediction for Treatment Success
時間枠:3 months after ultrasound-guided injection
|
Performance of the AI-assisted prediction model in identifying patients who achieve successful clinical outcomes after ultrasound-guided injection therapy.
Treatment success will be defined according to achievement of the Minimal Clinically Important Difference (MCID) in KOOS and/or attainment of the Patient Acceptable Symptom State (PASS).
Predictive performance will be assessed using AUC, sensitivity, specificity, accuracy, positive predictive value, and negative predictive value.
|
3 months after ultrasound-guided injection
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Knee Pain Intensity
時間枠:Baseline, 1 month, and 3 months
|
Pain intensity assessed using the Visual Analog Scale (VAS; 0-10), with higher scores indicating greater pain severity.
|
Baseline, 1 month, and 3 months
|
|
Knee Function
時間枠:Baseline, 1 month, and 3 months
|
Functional status assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), including pain, stiffness, and physical function subscales.
Higher scores indicate worse symptoms and functional limitation.
|
Baseline, 1 month, and 3 months
|
|
Knee Injury and Osteoarthritis Outcome Score (KOOS)
時間枠:Baseline, 1 month, and 3 months
|
Clinical improvement following ultrasound-guided injection therapy assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS).
Higher scores indicate better knee function and fewer symptoms.
|
Baseline, 1 month, and 3 months
|
|
Patient Acceptable Symptom State (PASS)
時間枠:3 months after treatment
|
Proportion of participants achieving a patient-acceptable symptom state following treatment according to validated PASS criteria.
|
3 months after treatment
|
|
Reliability of Ultrasound Measurements
時間枠:Baseline
|
Intra-rater and inter-rater reliability of ultrasound measurements assessed using the Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), Minimal Detectable Change (MDC), and Bland-Altman analysis.
|
Baseline
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。