Intelligent Microcatheter Shaping for Intracranial Aneurysm Coil Embolization
Safety and Effectiveness of Intelligent Microcatheter Shaping Simulation Technology in Coil Embolization of Intracranial Aneurysms: A Prospective, Multicenter, Observational, Real-World Registry Study
This prospective, multicenter, observational registry study will evaluate the real-world safety, effectiveness, and clinical value of artificial intelligence (AI)-assisted microcatheter shaping during coil embolization of intracranial aneurysms.
Adults with an intracranial aneurysm who are scheduled to undergo coil embolization will be enrolled and followed for approximately 12 months. The study will not assign participants to a treatment strategy. All treatment decisions will be made by the treating physicians according to routine clinical practice.
Participants will be analyzed according to whether microcatheter shaping is performed based on the physician's experience alone or with assistance from an intelligent microcatheter shaping simulation technology. The study will evaluate major adverse events within 12 months, immediate aneurysm occlusion after the procedure, clinical and quality-of-life outcomes, follow-up imaging findings, serious adverse events, repeat treatment or rehospitalization, microcatheter delivery performance, and health care resource use. At least 1,438 participants are planned to be enrolled.
調査の概要
状態
条件
詳細な説明
Microcatheter shaping is an important technical step in the endovascular coil embolization of intracranial aneurysms. The shape and stability of the microcatheter may affect access to the aneurysm, coil delivery, procedural efficiency, and procedural safety. The AI-assisted microcatheter shaping simulation technology evaluated in this study analyzes three-dimensional cerebrovascular anatomy to assist with aneurysm localization and measurement and to generate a suggested microcatheter shaping plan. The technology provides decision support, while the treating physician remains responsible for all clinical decisions.
This is a prospective, multicenter, observational, real-world registry study. Adult patients with an intracranial aneurysm confirmed by computed tomography angiography, magnetic resonance angiography, or digital subtraction angiography and scheduled to undergo coil embolization may be enrolled after providing written informed consent. Participants will not be randomly assigned to a treatment group, and participation in the registry will not determine the treatment received.
For analysis, participants will be classified into two observational cohorts according to actual clinical practice. In the physician-experience cohort, microcatheter shaping is performed according to the treating physician's experience. In the AI-assisted cohort, microcatheter shaping is performed with support from the intelligent microcatheter shaping simulation technology.
Study information will be collected during six planned visits: screening, the procedure, the postoperative hospitalization period, approximately 30 days after treatment, approximately 180 days after treatment, and approximately 360 days after treatment. Collected data will include participant characteristics, medical history, aneurysm and parent-artery morphology, procedural and device information, medication use, microcatheter delivery time and attempts, number of shaping attempts, microcatheter stability, clinical outcomes, quality of life, imaging outcomes, adverse events, serious adverse events, repeat interventions, rehospitalizations, and health care resource use.
The primary safety evaluation is the occurrence of major adverse events within 12 months, defined as neurological death or major ischemic or hemorrhagic stroke. Major stroke is defined as an increase of at least 4 points on the National Institutes of Health Stroke Scale. The primary effectiveness evaluation is immediate adequate aneurysm occlusion after coil embolization, defined as Raymond grade I or II.
Because the use of AI-assisted technology is determined by routine clinical practice rather than random assignment, statistical analyses will focus on estimating differences between the two cohorts while accounting for potential confounding factors. Regression-based adjustment will be used, with propensity score methods and sensitivity analyses considered when appropriate.
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Hongqi Zhang, M.D
- 電話番号:+8613601374152
- メール:xwzhanghq@163.com
研究連絡先のバックアップ
- 名前:Xin Su, M.D
- 電話番号:+8618210685023
- メール:1258940078@qq.com
研究場所
-
-
-
Beijing、中国、100053
- Xuanwu Hospital
-
コンタクト:
- Xin Su
- 電話番号:+8618210685023
- メール:1258940078@qq.com
-
コンタクト:
- Yongjie Ma, M.D
- メール:mayongjiexuanwu@163.com
-
副調査官:
- Yongjie Ma, M.D
-
-
参加基準
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Age 18 years or older, with no restriction based on sex.
- Diagnosis of an intracranial aneurysm confirmed by computed tomography angiography, magnetic resonance angiography, or digital subtraction angiography, with the target aneurysm planned for treatment by coil embolization.
- Ability to understand the study requirements and treatment procedures and provision of written informed consent before any study-specific procedure.
Exclusion Criteria:
- Currently unable or expected to be unable to complete the 1-year follow-up.
- Participation in another clinical study that may affect the results of this study.
- Life expectancy of less than 1 year because of another disease or medical condition.
- Considered unsuitable for participation by the investigator.
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Physician-Experience Cohort
Participants undergoing coil embolization of an intracranial aneurysm in whom microcatheter shaping is performed according to the treating physician's experience, without assistance from the intelligent microcatheter shaping simulation technology.
|
Microcatheter shaping is planned and performed by the treating physician according to clinical experience without assistance from the intelligent microcatheter shaping simulation technology.
The shaping approach is determined during routine clinical care and is not assigned by the study protocol.
|
|
AI-Assisted Cohort
Participants undergoing coil embolization of an intracranial aneurysm in whom microcatheter shaping is performed with assistance from the intelligent microcatheter shaping simulation technology.
|
An artificial intelligence-based decision-support technology that analyzes three-dimensional cerebrovascular anatomy, assists with aneurysm localization and measurement, and provides a suggested microcatheter shaping plan for intracranial aneurysm coil embolization.
Use of the technology is determined by routine clinical practice and is not assigned by the study protocol.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Incidence of Major Adverse Events Within 12 Months
時間枠:From the index procedure through 12 months after the procedure
|
Percentage of participants who experience at least one major adverse event from the index coil embolization procedure through 12 months.
A major adverse event is defined as neurological death or major ischemic or hemorrhagic stroke.
Major stroke is defined as an increase of at least 4 points on the National Institutes of Health Stroke Scale.
|
From the index procedure through 12 months after the procedure
|
|
Immediate Adequate Occlusion of the Target Aneurysm
時間枠:Immediately after coil embolization on the day of the procedure
|
Percentage of participants whose treated target aneurysm is classified as Raymond grade I or II on angiographic assessment immediately after coil embolization.
|
Immediately after coil embolization on the day of the procedure
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Modified Rankin Scale Score
時間枠:At hospital discharge or Day 7 after the procedure, 30 days (±15 days), 180 days (±30 days), and 360 days (±45 days) after the procedure
|
Distribution of modified Rankin Scale scores.
The scale ranges from 0 to 6, with 0 indicating no symptoms and 6 indicating death.
Lower scores indicate better functional status.
|
At hospital discharge or Day 7 after the procedure, 30 days (±15 days), 180 days (±30 days), and 360 days (±45 days) after the procedure
|
|
EQ-5D-5L Health Utility Index
時間枠:At baseline, hospital discharge or Day 7 after the procedure, 30 days (±15 days), 180 days (±30 days), and 360 days (±45 days) after the procedure
|
Health-related quality of life assessed using the EQ-5D-5L questionnaire, which evaluates mobility, self-care, usual activities, pain or discomfort, and anxiety or depression.
Responses will be converted to a health utility index according to the prespecified scoring method.
|
At baseline, hospital discharge or Day 7 after the procedure, 30 days (±15 days), 180 days (±30 days), and 360 days (±45 days) after the procedure
|
|
EQ Visual Analog Scale Score
時間枠:At baseline, hospital discharge or Day 7 after the procedure, 30 days (±15 days), 180 days (±30 days), and 360 days (±45 days) after the procedure
|
Participant-reported overall health status measured using the EQ Visual Analog Scale.
Scores range from 0 to 100, with higher scores indicating better self-reported health.
|
At baseline, hospital discharge or Day 7 after the procedure, 30 days (±15 days), 180 days (±30 days), and 360 days (±45 days) after the procedure
|
|
Incidence of Procedure-Related Serious Adverse Events
時間枠:From the index procedure through 12 months after the procedure
|
Percentage of participants who experience at least one serious adverse event considered by the investigator to be related to the coil embolization procedure.
|
From the index procedure through 12 months after the procedure
|
|
Incidence of Neurological Events
時間枠:From the index procedure through 12 months after the procedure
|
Percentage of participants who experience at least one neurological event, including ischemic stroke, hemorrhagic stroke, neurological death, intracranial hemorrhage, subarachnoid hemorrhage, arterial thrombosis, perforation or rupture of the parent artery or a branch artery, or transient ischemic attack.
|
From the index procedure through 12 months after the procedure
|
|
Incidence of Target Aneurysm Reintervention or Rehospitalization
時間枠:From hospital discharge through 12 months after the procedure
|
Percentage of participants who undergo repeat treatment of the target aneurysm or are rehospitalized after the index coil embolization procedure.
|
From hospital discharge through 12 months after the procedure
|
|
Length of Index Hospital Stay
時間枠:At hospital discharge, up to 30 days after admission for the index procedure.
|
Number of days from admission for the index coil embolization procedure to hospital discharge.
|
At hospital discharge, up to 30 days after admission for the index procedure.
|
|
Cumulative Treatment-Related Costs
時間枠:From the index hospitalization through 12 months after the procedure
|
Cumulative treatment-related costs in Chinese yuan, including costs of the index hospitalization, diagnostic examinations, surgical treatment, medical devices and consumables, medications, follow-up examinations, treatment of complications, direct nonmedical costs, and recorded indirect costs.
|
From the index hospitalization through 12 months after the procedure
|
|
Adequate Occlusion of the Target Aneurysm During Follow-Up
時間枠:At 180 days (±30 days) and 360 days (±45 days) after the procedure
|
Percentage of participants whose treated target aneurysm is classified as Raymond grade I or II on follow-up vascular imaging.
|
At 180 days (±30 days) and 360 days (±45 days) after the procedure
|
|
Incidence of Greater Than 50 Percent Parent Artery Stenosis
時間枠:At 180 days (±30 days) and 360 days (±45 days) after the procedure
|
Percentage of participants with greater than 50 percent stenosis of the parent artery at the location of the treated target aneurysm on follow-up vascular imaging.
|
At 180 days (±30 days) and 360 days (±45 days) after the procedure
|
|
Microcatheter Delivery Time
時間枠:During the index coil embolization procedure
|
Time required to deliver the microcatheter to the intended position for coil embolization, recorded in hours, minutes, and seconds.
|
During the index coil embolization procedure
|
|
Number of Microcatheter Delivery Attempts
時間枠:During the index coil embolization procedure
|
Number of attempts required to deliver the microcatheter to the intended position, categorized as 1, 2, 3, or more than 3 attempts.
|
During the index coil embolization procedure
|
|
Number of Microcatheter Shaping Attempts
時間枠:During the index coil embolization procedure
|
Number of microcatheter shaping attempts required during the procedure, categorized as 1, 2, 3, or more than 3 attempts.
|
During the index coil embolization procedure
|
|
Incidence of Microcatheter Instability
時間枠:During the index coil embolization procedure
|
Percentage of participants in whom microcatheter kickback or displacement occurs during coil embolization.
Microcatheter instability is recorded as a binary outcome of yes or no.
|
During the index coil embolization procedure
|
|
Incidence of Device-Related Serious Adverse Events
時間枠:From the index procedure through 12 months after the procedure
|
Percentage of participants who experience at least one serious adverse event considered by the investigator to be related to a device used during the coil embolization procedure, including the intelligent microcatheter shaping simulation technology when applicable.
|
From the index procedure through 12 months after the procedure
|
協力者と研究者
スポンサー
協力者
捜査官
- 主任研究者:Hongqi Zhang、Xuanwu Hospital, Beijing
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- xwzhqmayongjiesxwsmhyf
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。