Federated Learning for Point-of-Care Cardiac Ultrasound (FL-POCUS)

2026年8月31日 更新者:Truway Health, Inc.

A Prospective Multicenter Clinical-Performance Study of Federated Machine Learning for Automated Interpretation of Point-of-Care Cardiac Ultrasound

This prospective, multicenter study will evaluate a federated machine-learning system designed to analyze focused cardiac point-of-care ultrasound examinations. Federated learning allows participating clinical sites to contribute to model development while keeping raw ultrasound images and directly identifiable patient information within each site's controlled computing environment. Encrypted model updates, rather than patient images, will be transmitted for secure aggregation.

The prospective validation cohort will include approximately 3,000 adults undergoing clinically indicated focused cardiac ultrasound. Model performance will be compared with an expert interpretation of a comprehensive transthoracic echocardiogram performed within 24 hours. The primary objective is to determine how accurately the model identifies reduced left ventricular systolic function, defined as a left ventricular ejection fraction below 40%.

During the initial validation period, the investigational software will operate in silent mode. Its results will not be displayed to treating clinicians and will not be used to diagnose participants, select treatment, or replace standard clinical interpretation.

The study will also evaluate image-quality classification, cardiac-view recognition, performance across clinical sites and ultrasound systems, model calibration, processing time, cybersecurity, privacy resilience, and performance across demographic and clinical subgroups. Long-term monitoring will assess whether model performance changes as clinical populations, ultrasound equipment, acquisition practices, and software environments evolve during the 2026-2037 study period.

調査の概要

詳細な説明

Federated Learning for Point-of-Care Cardiac Ultrasound (FL-POCUS) is a prospective, multicenter clinical-performance study of a federated machine-learning system for focused cardiac point-of-care ultrasound. The study is intended to determine whether a diagnostic model can be developed and validated across multiple clinical environments without routinely transferring raw ultrasound images or directly identifiable participant information to a central training repository.

Participating institutions may use previously collected, locally governed ultrasound examinations during the federated model-development stage. Each institution will operate a local computing node using a common model architecture, data specification, and quality-control framework. Local model updates will be encrypted and transmitted to a secure aggregation service. The aggregated parameters will then be redistributed to participating sites for subsequent training rounds. Training events, software versions, data-quality findings, and model changes will be documented in an auditable version-control system.

Privacy protections will include access controls, secure aggregation, data-minimization procedures, cybersecurity testing, and evaluation for membership-inference and model-inversion risk. Raw ultrasound images, protected health information, consent records, participant identifiers, and authentication credentials will not be placed on a public blockchain. Any distributed ledger used by the study will be limited to document hashes, version identifiers, authorized attestations, and non-sensitive audit records.

After federated development is complete, the model will be version-locked before prospective clinical validation. Approximately 3,000 adult participants will be enrolled across at least six geographically and technically diverse clinical sites. Eligible participants will be undergoing a clinically indicated focused cardiac point-of-care ultrasound examination and will have an eligible comprehensive transthoracic echocardiogram available within 24 hours of the index examination.

The locked model will operate in silent mode. Investigational outputs will not be displayed to treating clinicians and will not influence diagnosis, treatment, patient disposition, or the decision to obtain additional testing. All clinical decisions will continue to be made through the participating institution's standard care processes.

The model will evaluate standard focused cardiac views, including parasternal long-axis, parasternal short-axis, apical four-chamber, and subcostal views when available. Investigational functions may include cardiac-view classification, image-quality assessment, identification of technically limited examinations, and detection of reduced left ventricular systolic function.

The primary outcome is the area under the receiver-operating-characteristic curve for detecting a reference-standard left ventricular ejection fraction below 40%. The proposed performance criterion is an area under the curve of at least 0.85, with the lower bound of the two-sided 95% confidence interval exceeding 0.80.

The reference standard will be established using comprehensive transthoracic echocardiography. Two qualified echocardiography readers, masked to the investigational model result, will independently review eligible reference examinations. Disagreements affecting the prespecified ejection-fraction category will be resolved by a third senior reader.

Secondary evaluations will include sensitivity, specificity, positive and negative predictive values, detection of severe systolic dysfunction, cardiac-view classification accuracy, agreement with expert image-quality assessments, nondiagnostic examination rate, calibration, processing time, site-level heterogeneity, and performance by ultrasound manufacturer and transducer type.

Prespecified subgroup analyses will examine performance by age, sex, race, ethnicity, body mass index category, clinical environment, cardiac rhythm, acquisition experience, study site, and ultrasound system. Subgroup results will be reported even when the model satisfies the overall primary performance criterion.

All attempted examinations will remain in the primary intention-to-diagnose analysis, including technically limited studies and examinations with incomplete cardiac views. A model output that cannot produce a valid diagnostic classification will be counted as a test failure in the primary analysis. An evaluable-case analysis may be performed as a secondary analysis.

The study includes a long-term performance-surveillance period extending through September 30, 2037. This period will evaluate model drift, calibration changes, equipment transitions, software updates, cybersecurity events, evolving acquisition practices, and changes in the enrolled population. Prospective data used for final validation will remain separated from model-development data unless a separately governed amendment authorizes a new model version. Any updated model will receive a new version designation and must undergo independent validation before clinical use.

Reportable study events will include unauthorized data disclosure, attempted reconstruction of participant information, incorrect linkage between examinations and participants, inadvertent display of investigational results, validation-data leakage into training, material subgroup-performance disparities, cybersecurity incidents, and significant protocol deviations.

The study will not authorize automated diagnosis or autonomous clinical management. Any later investigation in which model results are displayed to clinicians or used to influence care will require a separately approved protocol, updated risk assessment, applicable regulatory review, and independent Institutional Review Board authorization.

研究の種類

観察的

入学 (推定)

3000

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • New York
      • New York、New York、アメリカ、10016
        • Truway Health, Inc.

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

非確率サンプル

調査対象母集団

The study population will consist of adults receiving care in emergency departments, inpatient units, outpatient clinics, or other participating clinical settings who undergo a clinically indicated point-of-care cardiac ultrasound examination and a reference transthoracic echocardiogram within 24 hours. Consecutive eligible participants will be enrolled without selection based on expected left ventricular function or image quality. The cohort is intended to represent diverse clinical sites, ultrasound devices, operators, demographic groups, body compositions, cardiac rhythms, and levels of left ventricular systolic function encountered in routine care.

説明

Inclusion Criteria:

  • Age 18 years or older.
  • Undergoing a clinically indicated point-of-care cardiac ultrasound (POCUS) examination at a participating site.
  • Reference transthoracic echocardiogram completed within 24 hours of the index POCUS examination.
  • At least one cardiac ultrasound view attempted during the index examination.
  • POCUS and reference echocardiography records can be linked using an authorized coded study identifier.
  • Participant consent obtained or inclusion authorized under an Institutional Review Board-approved consent waiver, as applicable.

Exclusion Criteria:

  • Reference transthoracic echocardiogram not completed within 24 hours of the index POCUS examination.
  • Major cardiac procedure or substantial hemodynamic intervention occurring between the POCUS examination and reference echocardiogram, including cardiac surgery, cardioversion, cardiac arrest, or initiation of mechanical circulatory support.
  • Ultrasound or reference data are missing, corrupted, irretrievable, or cannot be securely linked.
  • Previous inclusion of the same participant in the primary validation cohort, unless repeat examinations are authorized under a prespecified longitudinal analysis.
  • Declines participation when individual informed consent is required.
  • Member of a population not authorized for enrollment under the applicable Institutional Review Board approval.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
Prospective Silent-Mode Federated Cardiac Ultrasound Validation Cohort
Approximately 3,000 adults undergoing clinically indicated focused cardiac point-of-care ultrasonography will be included in this prospective cohort. Each participant's cardiac ultrasound examination will be evaluated by the locked Federated Learning for Point-of-Care Cardiac Ultrasound (FL-POCUS) machine-learning model and compared with a reference transthoracic echocardiogram completed within 24 hours. Investigational model outputs will remain in silent mode and will not be displayed to treating clinicians or used to direct diagnosis, treatment, patient disposition, or additional testing. All attempted examinations, including technically limited studies and examinations with incomplete views, will remain in the primary intention-to-diagnose analysis.
A clinically indicated, noninvasive focused cardiac ultrasound examination performed through a point-of-care ultrasound system. Standard views may include parasternal long-axis, parasternal short-axis, apical four-chamber, and subcostal views. The examination will be evaluated for image quality, cardiac-view classification, left ventricular function, and evidence of reduced left ventricular ejection fraction.
他の名前:
  • Point-of-Care Ultrasound; POCUS; Focused Cardiac Ultrasound; FoCUS; Cardiac Ultrasonography
Investigational software that analyzes focused cardiac point-of-care ultrasound examinations using a version-locked federated machine-learning model. The system evaluates cardiac-view classification, image quality, left ventricular function, and the probability of a left ventricular ejection fraction below 40%. During this observational validation study, all model outputs will remain in silent mode and will not influence clinical care. Raw ultrasound images and directly identifiable participant information will remain within each participating site's controlled environment.
他の名前:
  • FL-POCUS; Federated Learning POCUS System; Federated Cardiac Ultrasound Model; Silent-Mode Echocardiography AI

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Diagnostic Performance for Detecting Reduced Left Ventricular Systolic Function
時間枠:Day 1 (within 24 hours after the index point-of-care ultrasound examination)
Area under the receiver operating characteristic curve (AUROC) of the locked federated-learning point-of-care ultrasound (POCUS) model for identifying left ventricular ejection fraction below 40%, using masked expert core-laboratory interpretation of the reference transthoracic echocardiogram as the reference standard. Analysis will be performed at the participant level with a two-sided 95% confidence interval.
Day 1 (within 24 hours after the index point-of-care ultrasound examination)

二次結果の測定

結果測定
メジャーの説明
時間枠
Sensitivity and Specificity for Detecting Left Ventricular Ejection Fraction Below 40%
時間枠:Day 1 (within 24 hours after the index point-of-care ultrasound examination)
Participant-level sensitivity and specificity of the locked model at the prespecified decision threshold for detecting left ventricular ejection fraction below 40%, compared with masked expert core-laboratory interpretation of the reference transthoracic echocardiogram. Results will include two-sided 95% confidence intervals.
Day 1 (within 24 hours after the index point-of-care ultrasound examination)
Diagnostic Performance for Detecting Severe Left Ventricular Systolic Dysfunction
時間枠:Day 1 (within 24 hours after the index point-of-care ultrasound examination)
AUROC of the locked model for identifying severe left ventricular systolic dysfunction, defined as a reference left ventricular ejection fraction below 30%. Sensitivity and specificity at the prespecified decision threshold will also be reported.
Day 1 (within 24 hours after the index point-of-care ultrasound examination)
Cardiac Ultrasound View Classification Accuracy
時間枠:Day 1 (index point-of-care ultrasound examination)
Percentage of acquired ultrasound clips correctly classified by the model as parasternal long-axis, parasternal short-axis, apical four-chamber, subcostal, or other view, compared with blinded expert-reader classification.
Day 1 (index point-of-care ultrasound examination)
Agreement of Automated and Expert Image-Quality Classification
時間枠:Day 1 (index point-of-care ultrasound examination)
Agreement between model-generated and blinded expert-reader image-quality ratings. Images will be categorized as diagnostic, technically limited, or nondiagnostic. Percentage agreement and weighted kappa with a two-sided 95% confidence interval will be reported.
Day 1 (index point-of-care ultrasound examination)
Nondiagnostic Model Output Rate
時間枠:Day 1 (index point-of-care ultrasound examination)
Percentage of attempted participant examinations for which the locked model cannot generate a valid left ventricular systolic-function classification because of inadequate image quality, incomplete acquisition, unsupported cardiac view, or technical processing failure.
Day 1 (index point-of-care ultrasound examination)
Calibration of Predicted Reduced Left Ventricular Function Risk
時間枠:Day 1 (within 24 hours after the index point-of-care ultrasound examination)
Agreement between the model-predicted probability and observed occurrence of left ventricular ejection fraction below 40%. Calibration will be evaluated using the calibration intercept, calibration slope, and Brier score.
Day 1 (within 24 hours after the index point-of-care ultrasound examination)
Model Processing Time
時間枠:Day 1 (index point-of-care ultrasound examination)
Median elapsed time, measured in seconds, from availability of the completed ultrasound examination to generation of the locked model output. The interquartile range and 95th percentile will also be reported.
Day 1 (index point-of-care ultrasound examination)
Cross-Site and Ultrasound-Device Generalizability
時間枠:From model lock through primary completion, up to 10 years.
AUROC for detecting left ventricular ejection fraction below 40% will be calculated separately by participating site and ultrasound-device manufacturer. Performance heterogeneity will be summarized using the range of site-specific and device-specific AUROCs and a hierarchical random-effects analysis.
From model lock through primary completion, up to 10 years.
Longitudinal Model Performance Drift
時間枠:Annually from model lock through primary completion, up to 10 years.
Annual change in AUROC, sensitivity, specificity, calibration slope, and nondiagnostic output rate relative to the first completed validation year. The model and decision threshold will remain locked during prospective validation unless a protocol-defined model update is separately evaluated.
Annually from model lock through primary completion, up to 10 years.

その他の成果指標

結果測定
メジャーの説明
時間枠
Federated-Learning Privacy Attack Resistance
時間枠:Before prospective deployment and annually through study completion, up to 11 years.
Resistance of the federated-learning system to prespecified membership-inference and model-inversion tests. Membership-inference attack AUROC and the percentage of testing attempts producing recognizable reconstruction of source ultrasound data will be reported.
Before prospective deployment and annually through study completion, up to 11 years.

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Gavin Solomon, MD、Truway Health, Inc.

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

便利なリンク

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年8月31日

一次修了 (推定)

2036年10月1日

研究の完了 (推定)

2037年9月30日

試験登録日

最初に提出

2026年8月27日

QC基準を満たした最初の提出物

2026年8月31日

最初の投稿 (実際)

2026年9月2日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月2日

QC基準を満たした最後の更新が送信されました

2026年8月31日

最終確認日

2026年8月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

はい

IPD プランの説明

De-identified individual participant data underlying the reported study results will be made available. Shared data may include coded demographic characteristics, clinical setting, ultrasound-device category, POCUS acquisition characteristics, expert reference left ventricular ejection fraction, locked-model predictions, image-quality classifications, and analyzed outcome variables. Direct identifiers will not be shared. Raw ultrasound files will be available only through controlled access when permitted by the originating site, informed-consent terms, and applicable privacy requirements.

IPD 共有時間枠

Data will become available beginning 12 months after publication of the primary study results and will remain available for 10 years.

IPD 共有アクセス基準

Access will be considered for qualified scientific researchers who submit a methodologically sound research proposal. Requests will undergo review by the sponsor's data-access committee and, when applicable, participating institutions. Approved researchers must execute a data-use agreement, protect confidentiality, refrain from re-identification, use the data only for the approved purpose, and comply with applicable Institutional Review Board, privacy, security, and publication requirements. Data will be provided through a controlled-access environment.

IPD 共有サポート情報タイプ

  • STUDY_PROTOCOL
  • SAP
  • ICF
  • ANALYTIC_CODE
  • CSR

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

はい

米国で製造され、米国から輸出された製品。

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する