このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Titanium Particle Release Across Non-Surgical Peri-implantitis Therapies

2026年9月4日 更新者:Özlem SARAÇ ATAGÜN、Saglik Bilimleri Universitesi

Evaluation of the Effects of Peri-implantitis Treatment Approaches on Titanium Particle Release

This prospective, randomized, controlled, single-blind, in vivo clinical and laboratory study aims to quantitatively compare the clinical success and metal ion release associated with four different non-surgical decontamination methods in the management of peri-implantitis. A total of 70 implants (56 peri-implantitis implants divided into four treatment groups, and 14 healthy control implants) will be included. Clinical parameters will be evaluated at baseline and 6 weeks, and multi-element trace metal levels (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) in peri-implant sulcular fluid (PISF) and granulation tissue will be analyzed using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) at baseline, 24 hours, and 6 weeks.

調査の概要

詳細な説明

Background and Rationale:

Peri-implantitis is a multifactorial inflammatory disease characterized by inflammation in the peri-implant soft tissues and progressive loss of supporting crestal bone. Non-surgical treatment protocols primarily aim to eliminate pathogenic bacterial biofilm and reduce local inflammation. However, mechanical forces and physical methods applied during these procedures can cause micro- and macro-level surface alterations on dental implants, leading to the release of metallic micro- and nanoparticles into the surrounding tissues. These released metal ions and particles can trigger foreign body reactions, macrophage polarization, and elevated cytokine expression, thereby exacerbating bone resorption independently of the biofilm. Although various non-surgical decontamination methods are clinically utilized, data evaluating their short- and medium-term metal release kinetics alongside clinical outcomes through prospective in vivo designs remain limited.

Objectives and Hypotheses:

The primary objective of this study is to prospectively compare the clinical efficacy of four different non-surgical decontamination methods and to quantitatively assess their impact on multi-element trace metal release (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) in peri-implant sulcular fluid (PISF) and granulation tissue. The study will test hypotheses regarding whether different treatment modalities create significant differences in clinical parameters (Probing Depth, Plaque Index, Bleeding on Probing, Gingival Index, Clinical Attachment Level) and metal ion load, while determining the most biocompatible and minimally invasive protocol.

Study Design and Patient Population:

This study is designed as a prospective, randomized, controlled, single-blind, in vivo clinical and laboratory trial. A total of 70 implants will be evaluated: 56 peri-implantitis implants and 14 healthy control implants. Peri-implantitis cases will be randomly allocated using computer-generated block randomization via the sequentially numbered opaque sealed envelope (SNOSE) method into four parallel treatment groups (14 implants per group):

Group 1 (Titanium Curette): Mechanical debridement using titanium curettes (10-15 strokes per surface horizontally and apico-coronally).

Group 2 (Plastic Curette): Mechanical debridement using implant-compatible plastic curettes adhering to the same stroke and directional principles.

Group 3 (Diode Laser): Diode laser application (940 nm, 1 W average power, non-contact mode, 300 µm fiber tip for 60 seconds).

Group 4 (EMS Air-Flow + PEEK): Guided Biofilm Therapy (GBT) protocol utilizing submarginal erythritol powder via PerioFlow nozzle, followed by a PEEK instrument (Piezon PI) to remove remaining calcified deposits.

Group 5 (Healthy Control): Individuals with peri-implant health receiving no treatment intervention, undergoing clinical monitoring and PISF collection only.

Procedures and Assessments:

Clinical Parameters: Probing Depth (PD), Bleeding on Probing (BoP), Plaque Index (PI), Gingival Index (GI), and Clinical Attachment Level (CAL) will be recorded at baseline (T0) and at 6 weeks (T2) by a blinded and calibrated investigator. PISF Sampling: Peri-implant sulcular fluid samples will be collected using sterile paper strips (Periopaper) at baseline (T0), 24 hours post-treatment (T1), and 6 weeks post-treatment (T2). Fluid volume will be measured via Periotron and stored at -80°C.

Granulation Tissue Sampling: Inflammatory granulation tissue samples will be collected during debridement (or via gentle sulcular sampling for laser and air-flow groups, strictly avoiding contact with the titanium surface) and placed in sterile eppendorf tubes.

ICP-MS Analysis: Biological samples will undergo microwave-assisted acid digestion and quantitative elemental analysis (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) at an accredited laboratory. Baseline metal loads of materials (such as erythritol powder and blank Periopaper strips) will be accounted for and subtracted.

研究の種類

介入

入学 (推定)

70

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

  • 名前:İrem Sezen, DDS, PhD Candidate
  • 電話番号:+905426982624
  • メール:iremszn@gmail.com

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

はい

説明

Inclusion Criteria:

  • Being systemically healthy and older than 18 years of age.
  • Having implants diagnosed with peri-implantitis according to the 2017 World Workshop criteria (probing depth ≥ 5 mm, bleeding on probing positive, radiographic bone loss > 2 mm).
  • Dental implants being in function in the oral cavity for at least 1 year.

Exclusion Criteria:

  • Having received systemic antibiotic therapy within the past 3 months.
  • Having previously received peri-implantitis treatment at the relevant implant site.
  • Being pregnant or lactating.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:Arm 1: Titanium Curette Group
Mechanical debridement performed using specialized medical-grade titanium curettes. The treatment protocol involves applying 10-15 systematic strokes per implant surface in both horizontal and apico-coronal directions to thoroughly decontaminate the infected implant threads and remove subgingival biofilm and calculus.
This arm evaluates standard mechanical debridement using medical-grade titanium curettes, applied as 10-15 systematic strokes per implant surface horizontally and apico-coronally. Unlike conventional studies that focus solely on clinical indices, this protocol uniquely combines mechanical cleaning with quantitative Inductively Coupled Plasma Mass Spectrometry (ICP-MS) analysis to measure multi-element trace metal release (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) in both peri-implant sulcular fluid (PISF) and inflammatory granulation tissue, determining the specific particulate load generated by metallic curettage.
他の名前:
  • Non-surgical Peri-implantitis treatment with Titanium Curettes
実験的:Arm 2: Plastic Curette Group
Mechanical debridement performed using implant-compatible, flexible plastic curettes. The procedure strictly adheres to the same standardized stroke count and directional mechanics (10-15 strokes per surface horizontally and apico-coronally) to minimize aggressive surface scratching while eliminating bacterial plaque.
This arm utilizes implant-compatible, flexible plastic curettes adhering to identical stroke parameters (10-15 strokes per surface horizontally and apico-coronally). Its unique methodological value lies in comparing polymer-based mechanical instrumentation against metallic counterparts, specifically quantifying whether non-metallic mechanical debridement mitigates multi-element trace metal release (analyzed via ICP-MS across 11 elemental parameters in PISF and granulation tissue) while maintaining therapeutic clinical efficacy in peri-implantitis management.
他の名前:
  • Non-surgical Peri-implantitis treatment with Plastic Curettes
実験的:Arm 3: Diode Laser Group
Laser-assisted surface decontamination utilizing a diode laser system operating at a wavelength of 940 nm. The protocol is administered in a non-contact mode with an average power of 1 W, utilizing a 300 µm fiber tip applied for 60 seconds per implant surface to achieve bactericidal and decontamination effects.
This arm implements a laser-assisted decontamination protocol using a 940 nm diode laser operated in non-contact mode at an average power of 1 W with a 300 µm fiber tip applied for 60 seconds per surface. This intervention investigates the thermal and bactericidal efficacy of optical decontamination, uniquely pairing it with high-precision ICP-MS trace metal quantification (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) from PISF and granulation tissue samples to evaluate whether photon-based decontamination induces surface alterations or ion shedding compared to mechanical modalities.
他の名前:
  • Laser-Assisted Decontamination Protocol
実験的:Arm 4: EMS Air-Flow + PEEK Group
A two-step Guided Biofilm Therapy (GBT) approach. First, submarginal air-polishing is performed using erythritol powder delivered via a specialized PerioFlow nozzle to remove soft biofilm. Second, residual hard deposits are carefully cleared using a medical-grade PEEK (Polyetheretherketone) instrument (Piezon PI) designed to prevent titanium surface scarring.
This arm employs a two-step Guided Biofilm Therapy (GBT) protocol combining submarginal air-polishing with erythritol powder via a PerioFlow nozzle followed by a medical-grade PEEK (Piezon PI) instrument for hard deposit removal. This advanced combination protocol is uniquely designed to eliminate biofilm without scarring the titanium surface, its safety and efficacy rigorously validated through quantitative multi-element ICP-MS analysis of 11 trace metals in PISF and granulation tissue samples collected at baseline, 24 hours, and 6 weeks.
他の名前:
  • Peri-implantitis Guided Biofilm Therapy (GBT) Protocol
他の:Arm 5: Healthy Control Group
Individuals presenting with healthy peri-implant tissues who receive no therapeutic or surgical decontamination intervention. This cohort serves as a non-intervention control group to establish baseline comparative values for clinical metrics, peri-implant sulcular fluid (PISF) volume, and multi-element trace metal concentrations.
This non-intervention control cohort comprises individuals with clinically healthy dental implants who receive no surgical or therapeutic decontamination. It serves as a vital comparative baseline for the study, allowing researchers to evaluate physiological baseline levels of multi-element trace metal concentrations (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) in PISF and tissue samples relative to diseased, treated implant sites without confounding therapeutic variables.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Change in Multi-Element Trace Metal Concentrations (Titanium Ion Release) in Peri-Implant Sulcular Fluid (PISF)
時間枠:Baseline (T0), 24 hours post-treatment (T1), and 6 weeks post-treatment (T2)
Quantitative analysis of multi-element trace metal concentrations-specifically Titanium (Ti) along with Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, and Pb-released into the peri-implant sulcular fluid (PISF). PISF samples will be collected using sterile Periopaper strips, quantified via Periotron, stored at -80°C, and analyzed using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) following microwave-assisted acid digestion, subtracting baseline material blanks.
Baseline (T0), 24 hours post-treatment (T1), and 6 weeks post-treatment (T2)

二次結果の測定

結果測定
メジャーの説明
時間枠
Change in Probing Depth (PD)
時間枠:Baseline (T0) and 6 weeks post-treatment (T2)
Assessment of peri-implant pocket depth reduction measured in millimeters using a standardized periodontal probe from the mucosal margin to the base of the peri-implant pocket. All measurements will be recorded by a blinded and calibrated investigator.
Baseline (T0) and 6 weeks post-treatment (T2)
Change in Bleeding on Probing (BoP)
時間枠:Baseline (T0) and 6 weeks post-treatment (T2)
Evaluation of mucosal inflammation around the dental implants, recorded dichotomously as the presence or absence of bleeding within 30 seconds following gentle probing of the peri-implant sulcus.
Baseline (T0) and 6 weeks post-treatment (T2)
Change in Plaque Index (PI)
時間枠:Baseline (T0) and 6 weeks post-treatment (T2)
Quantification of microbial plaque accumulation and oral hygiene status surrounding the dental implant sites, evaluated using standardized clinical scoring criteria.
Baseline (T0) and 6 weeks post-treatment (T2)
Change in Gingival Index (GI)
時間枠:Baseline (T0) and 6 weeks post-treatment (T2)
Assessment of the severity of peri-implant mucosal inflammation based on visual characteristics and tissue response to mild probing around the implant perimeter.
Baseline (T0) and 6 weeks post-treatment (T2)
Change in Clinical Attachment Level (CAL)
時間枠:Baseline (T0) and 6 weeks post-treatment (T2)
Quantification of the distance from a fixed anatomical or prosthetic reference point (such as the implant shoulder or crown margin) to the base of the pocket, serving as an indicator of supporting tissue status.
Baseline (T0) and 6 weeks post-treatment (T2)
Change in Multi-Element Trace Metal Concentrations in Inflammatory Granulation Tissue
時間枠:Only at baseline (T0) during debridement
Quantitative elemental analysis of multi-element trace metal levels (Ti, Al, V, Co, Cr, Cu, Zr, Fe, Ni, As, Pb) in inflammatory granulation tissue samples collected during debridement (or via gentle sulcular sampling for non-contact groups) using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) following microwave-assisted acid digestion.
Only at baseline (T0) during debridement

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年10月15日

一次修了 (推定)

2027年4月15日

研究の完了 (推定)

2027年6月15日

試験登録日

最初に提出

2026年9月3日

QC基準を満たした最初の提出物

2026年9月4日

最初の投稿 (実際)

2026年9月10日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月10日

QC基準を満たした最後の更新が送信されました

2026年9月4日

最終確認日

2026年9月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

はい

IPD 共有サポート情報タイプ

  • STUDY_PROTOCOL
  • SAP
  • ICF

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。