Comparison of Autologous Tooth and Bovine Xenograft in Periodontal Healing After Mandibular Third Molar Extraction
Evaluation of Changes in Probing Depth Following Surgical Extraction of Mandibular Third Molars Using Particulated Autologous Tooth vs. Particulated Bovine Xenograft vs. Blood Clot: A Randomized Clinical Trial
調査の概要
詳細な説明
This study investigates the healing of periodontal defects on the distal surface of the second lower molars after the surgical extraction of impacted third molars. Specifically, it compares the effectiveness of autologous tooth graft particles (derived from the extracted third molar) with bovine xenograft particles, using blood clot healing as a control.
Lower third molars are the most frequently impacted teeth, and their extraction can sometimes lead to or worsen periodontal defects on the adjacent second molar. Previous studies have shown positive outcomes using various bone regeneration materials; however, autologous tooth grafts have recently emerged as a biocompatible, osteoconductive, and osteoinductive alternative with promising results. Despite this, there are no clinical studies directly comparing autologous tooth grafts and bovine xenografts in this context-justifying the present research.
A prospective, randomized split-mouth clinical trial with three arms will be conducted at the Complutense University of Madrid. Each patient will undergo bilateral lower third molar extractions under three conditions:
Group A (Test 1): socket filled with autologous tooth graft,
Group B (Test 2): socket filled with bovine xenograft,
Group C (Control): socket left to heal naturally with a blood clot.
The main objective is to evaluate the reduction in probing depth on the distal surface of the second molar six months post-extraction.
Secondary outcomes include postoperative pain, inflammation, trismus, complications, wound healing, and patient-reported outcomes (PoSSe questionnaire).
Approximately 30 patients will be included, with triple randomization (side of first extraction, use of graft, and graft type). Clinical and radiographic evaluations will be performed preoperatively, and follow-ups will occur at 48 hours, one week, three months, and six months.
The null hypothesis (H₀) states that there will be no periodontal differences between the two graft materials, while the alternative hypothesis (H₁) proposes superior periodontal outcomes with the autologous tooth graft compared to the bovine xenograft.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Miguel Ruiz Rincón, DDS
- 電話番号:+34 680276072
- メール:migrui02@ucm.es
研究場所
-
-
Madrid
-
Madrid、Madrid、スペイン、28040
- 募集
- Postgrado de especialización en cirugía bucal e implantología, Facultad de Odontología, Universidad Complutense de Madrid
-
コンタクト:
- Miguel Ruiz Rincón, DDS
- 電話番号:+34 680 27 60 72
- メール:migrui02@ucm.es
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Adults (≥18 years old) of any sex, able to understand and follow study instructions.
- Patients requiring bilateral surgical extraction of impacted lower third molars in horizontal or mesioangular position.
- Presence of both lower second molars.
- Classified as ASA I or ASA II (according to the American Society of Anesthesiologists).
- Willingness to participate voluntarily and sign informed consent.
Exclusion Criteria:
- Age under 18 years.
- ASA physical status III, IV, V, or VI.
- Pregnant or breastfeeding women.
- Immunosuppressed patients.
- Current treatment with NSAIDs, anticoagulants, or acetylsalicylic acid.
- Previous or current treatment with bisphosphonates.
- Presence of oral dysplasia or precancerous lesions.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Autologous Tooth Graft (Test 1)
After surgical extraction of the impacted lower third molar, the socket will be filled with autologous tooth graft particles obtained from the extracted tooth using the Smart Dentin Grinder®.
The graft particles (300-1200 µm) will be decontaminated, rinsed, and placed on the distal surface of the second molar.
The graft will be covered with a resorbable hemostatic sponge (Roeko Gelatamp®) before suturing.
|
Autologous tooth graft particles are prepared from the extracted third molar using the Smart Dentin Grinder®.
The tooth is cleaned, dried, and ground to particles of 300-1200 µm, decontaminated with 0.5 M sodium hydroxide and 20% ethanol, rinsed with sterile saline, and placed on the distal surface of the second molar.
The graft is covered with a resorbable hemostatic sponge (Roeko Gelatamp®) prior to wound closure.
他の名前:
|
|
アクティブコンパレータ:Bovine Xenograft (Test 2)
After extraction of the impacted lower third molar, the socket will be filled with particulate bovine xenograft (InterOss®) hydrated in sterile saline.
The material will be placed on the distal surface of the second molar and covered with a resorbable hemostatic sponge before suturing.
|
Autologous tooth graft particles are prepared from the extracted third molar using the Smart Dentin Grinder®.
The tooth is cleaned, dried, and ground to particles of 300-1200 µm, decontaminated with 0.5 M sodium hydroxide and 20% ethanol, rinsed with sterile saline, and placed on the distal surface of the second molar.
The graft is covered with a resorbable hemostatic sponge (Roeko Gelatamp®) prior to wound closure.
他の名前:
|
|
介入なし:Blood Clot (Control)
Following extraction of the impacted lower third molar, the socket will be left to heal naturally through blood clot formation, without placement of any graft material or hemostatic sponge.
Standard wound closure and postoperative care will be provided.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Reduction in probing depth on the distal surface of the mandibular second molar
時間枠:Baseline (preoperative), 3 months, and 6 months post-extraction
|
Periodontal probing depth (in millimeters) measured on the distal surface of the lower second molar using a calibrated periodontal probe (CP12).
The reduction in probing depth will be compared among the three groups (autologous tooth graft, bovine xenograft, and blood clot control) to evaluate periodontal healing following extraction of the lower third molars.
|
Baseline (preoperative), 3 months, and 6 months post-extraction
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Postoperative swelling
時間枠:Preoperative, 48 hours, and 7 days post-extraction
|
Facial swelling measured as the linear distance between anatomical landmarks (tragus-commissure, tragus-gonion, and gonion-commissure) using a suture thread and caliper.
|
Preoperative, 48 hours, and 7 days post-extraction
|
|
Postoperative trismus
時間枠:Preoperative, 48 hours, and 7 days post-extraction
|
Maximum interincisal mouth opening measured in millimeters using a caliper.
|
Preoperative, 48 hours, and 7 days post-extraction
|
|
Wound healing quality
時間枠:48 hours, and 7 days post-extraction
|
linical evaluation of the surgical site according to Blum's criteria (good, acceptable, poor), based on mucosal color, bleeding, wound margins, and closure.
|
48 hours, and 7 days post-extraction
|
|
Patient-reported quality of life
時間枠:7 days post-extraction
|
Assessed using the Postoperative Symptom Severity (PoSSe) scale, covering pain, function, daily activities, and social interaction after surgery.
|
7 days post-extraction
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Surgical time
時間枠:Intraoperatively
|
Minutes and seconds recorded intraoperatively
|
Intraoperatively
|
|
Surgical difficulty
時間枠:Intraoperatively
|
Classified according to the modified Parant scale: Types I-IV
|
Intraoperatively
|
協力者と研究者
協力者
捜査官
- スタディディレクター:José María Martínez-González, MD,DMD,PhD,MDV、Department of Dental Clinical Specialties, Faculty of Dentistry, Complutense University of Madrid
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 25/636-EC_X
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
IPD 共有時間枠
IPD 共有アクセス基準
IPD 共有サポート情報タイプ
- STUDY_PROTOCOL
- SAP
- ICF
- ANALYTIC_CODE
- CSR
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。