このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Capsular Tension Ring With Hydrophilic Versus Hydrophobic Intraocular Lenses (CTR-IOL-3ARM)

2026年9月21日 更新者:Ehab Mohamed Elsayed Mohamed Saad、Benha University

Outcomes of Hydrophilic Intraocular Lens Implantation With and Without a Capsular Tension Ring Versus Hydrophobic Intraocular Lens Implantation Alone: A Randomized Controlled Trial

This study compares three approaches to cataract surgery. Cataract surgery involves removing the eye's cloudy natural lens and replacing it with an artificial intraocular lens (IOL) to restore clear vision. IOLs are made from different materials, most commonly a "hydrophilic" (water-attracting) acrylic or a "hydrophobic" (water-repelling) acrylic. Hydrophilic lenses are generally easier and less expensive to use, but have been linked in past research to a higher chance of the lens capsule becoming cloudy again after surgery (posterior capsule opacification, or PCO), sometimes requiring a follow-up laser treatment. Hydrophobic lenses tend to have lower rates of this problem but can cost more.

A capsular tension ring (CTR) is a small flexible ring that can be placed inside the eye at the time of surgery to help hold the lens capsule in a stable, round shape. This study asks whether adding a CTR when a hydrophilic lens is used can reduce the disadvantages usually seen with that lens material.

600 adult patients (ages 50-80) undergoing cataract surgery at three hospitals in Egypt were randomly assigned to one of three groups: (1) a hydrophilic lens plus a CTR, (2) a hydrophobic lens alone (the common comparison approach), or (3) a hydrophilic lens alone without a CTR. Patients were followed for 24 months, and researchers compared vision, glasses prescription accuracy, lens position, capsule clouding, need for laser treatment, and surgical complications between the groups.

The results showed that adding a CTR to a hydrophilic lens produced results very similar to using a hydrophobic lens alone. In contrast, using a hydrophilic lens without a CTR resulted in worse vision, less accurate glasses prescriptions, more lens shifting or tilting, more capsule clouding, a higher need for laser treatment, and more complications compared with the hydrophobic lens. These findings suggest that adding a CTR may be a simple, low-cost way to improve outcomes when a hydrophilic lens is used for cataract surgery.

調査の概要

詳細な説明

Background and rationale: Phacoemulsification with intraocular lens (IOL) implantation is the standard treatment for age-related cataract. IOL material (hydrophilic versus hydrophobic acrylic) is a recognized determinant of long-term capsular biocompatibility, with hydrophobic acrylic lenses generally associated with lower rates of posterior capsule opacification (PCO) and reduced need for neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy compared with hydrophilic acrylic lenses. Capsular tension rings (CTRs) are polymethyl methacrylate devices that stabilize the capsular bag equator and have been proposed to mitigate capsular contraction, lens decentration, and PCO, independent of IOL material. Prior comparative work has generally examined either IOL material effects or CTR effects in isolation, or has compared a composite intervention (hydrophilic IOL plus CTR) against a hydrophobic IOL alone, without a design capable of isolating the CTR's independent contribution.

Objectives: To compare visual, refractive, anatomical (IOL position and posterior capsule opacification), and safety outcomes among three approaches to routine cataract surgery: (1) hydrophilic acrylic IOL implantation combined with a CTR (Group A); (2) hydrophobic acrylic IOL implantation alone (Group B); and (3) hydrophilic acrylic IOL implantation alone, without a CTR (Group C). The inclusion of Group C, using the same hydrophilic IOL model as Group A but without CTR insertion, was designed specifically to allow assessment of the CTR's independent contribution when compared against Group A, in addition to the material-based comparisons of Groups A and C against Group B.

Design: Prospective, randomized, parallel-group, three-arm controlled trial conducted at three tertiary ophthalmology centers in Egypt (Zagazig University Hospital, Benha University Hospital, and Al-Azhar University Hospital). Eligible adults aged 50-80 years with visually significant age-related cataract (LOCS III grade >=3) were randomized 1:1:1 using a computer-generated allocation sequence, with allocation concealment via sealed opaque envelopes opened intraoperatively. Outcome assessors and data analysts were blinded to treatment allocation; operating surgeons were not blinded due to the nature of the intervention.

Interventions: All participants underwent standardized phacoemulsification via a 2.2 mm clear corneal incision with a ~5.5 mm continuous curvilinear capsulorhexis. Group A received a hydrophilic acrylic IOL (Eyecryl, Biotech Healthcare, India) plus a polymethyl methacrylate CTR (Auroring CTR 11, Aurolab, India). Group B received a hydrophobic acrylic IOL (AcrySof IQ, Alcon Laboratories, USA) without a CTR. Group C received the same hydrophilic acrylic IOL as Group A, without CTR insertion.

Outcomes: Primary outcomes were best-corrected visual acuity (logMAR) and manifest spherical equivalent refractive error at 24 months, with longitudinal assessment at 1, 3, 6, 12, 18, and 24 months. Secondary outcomes included posterior capsule opacification grade (slit-lamp retroillumination, graded per Aslam et al.), Nd:YAG capsulotomy rate, IOL centration and tilt (anterior segment optical coherence tomography), and intraoperative and postoperative complications (posterior capsule rupture, zonular dialysis, vitreous loss, iris trauma, cystoid macular edema, intraocular pressure elevation, corneal edema, and endophthalmitis).

Follow-up: Scheduled visits at day 1, week 1, and months 1, 3, 6, 12, 18, and 24 postoperatively, with the 24-month visit representing the final prespecified assessment.

Statistical analysis: Continuous variables were compared across groups using one-way ANOVA or Kruskal-Wallis testing as appropriate, with post-hoc pairwise comparisons for Group A vs. Group B and Group C vs. Group B. Categorical variables were compared using chi-square or Fisher's exact test. Repeated-measures ANOVA assessed longitudinal group x time interactions for visual and refractive outcomes.

研究の種類

介入

入学 (実際)

600

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Benha
      • Banhā、Benha、エジプト、13111
        • Benha University

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Age 50-80 years
  • Visually significant age-related cataract, defined as nuclear opacity grade >=3 according to the Lens Opacities Classification System III (LOCS III), graded preoperatively under standardized mydriasis via slit-lamp biomicroscopy
  • Clear cornea
  • Adequate pupillary dilation
  • Anatomically normal capsular bag with no evidence of zonular weakness
  • No ocular comorbidities expected to affect visual or refractive outcomes

Exclusion Criteria:

  • Previous intraocular surgery
  • Ocular trauma
  • Pseudoexfoliation syndrome
  • Posterior polar cataract
  • Zonular instability
  • Complicated cataract
  • Active intraocular inflammation
  • Retinal or optic nerve pathology
  • Anticipated need for additional capsular support devices beyond the study protocol

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:U.S. flag An official website of the United States government Here's how you know Skip to main page

Phacoemulsification with implantation of a hydrophilic acrylic intraocular lens (Eyecryl, Biotech Healthcare, India) combined with insertion of a polymethyl methacrylate capsular tension ring (Auroring CTR 11, Aurolab, India).

Foldable hydrophilic acrylic intraocular lens implanted in the capsular bag following phacoemulsification.

Polymethyl methacrylate capsular tension ring (overall diameter 13.0 mm, compressed diameter 11.0 mm) inserted into the capsular bag to distribute equatorial zonular forces and maintain capsular bag contour.

アクティブコンパレータ:Group B: Hydrophobic IOL alone

Phacoemulsification with implantation of a hydrophobic acrylic intraocular lens (AcrySof IQ, Alcon Laboratories, USA), without a capsular tension ring.

Foldable hydrophobic acrylic intraocular lens implanted in the capsular bag following phacoemulsification.

実験的:Group C: Hydrophilic IOL alone

Phacoemulsification with implantation of the same hydrophilic acrylic intraocular lens used in Group A (Eyecryl, Biotech Healthcare, India), without capsular tension ring insertion.

Foldable hydrophilic acrylic intraocular lens implanted in the capsular bag following phacoemulsification.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Best-corrected visual acuity (BCVA)
時間枠:24 months postoperatively

Best-corrected visual acuity measured in logMAR units, assessed longitudinally at 1, 3, 6, 12, 18, and 24 months, with between-group comparison at 24 months as the primary efficacy endpoint.

24 months postoperatively

二次結果の測定

結果測定
メジャーの説明
時間枠
Manifest spherical equivalent refractive error
時間枠:24 months postoperatively

Manifest spherical equivalent refractive error (diopters), assessed longitudinally at 1, 3, 6, 12, 18, and 24 months, with between-group comparison at 24 months as the primary efficacy endpoint. Proportion of eyes within +/-0.5 D and +/-1.0 D of target refraction was also assessed at 24 months.

24 months postoperatively

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2022年12月15日

一次修了 (実際)

2026年5月15日

研究の完了 (実際)

2026年5月15日

試験登録日

最初に提出

2026年9月21日

QC基準を満たした最初の提出物

2026年9月21日

最初の投稿 (実際)

2026年9月25日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月25日

QC基準を満たした最後の更新が送信されました

2026年9月21日

最終確認日

2026年9月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • ZU-BU-AU-CTR-IOL-3ARM-2023

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する