Evaluation of Unexplained Severe Syncope in a Modern Syncope Unit (Diamond)
Evidence-based Evaluation of Unexplained Severe Syncope in a Modern Syncope Unit: an Observational Study
The aim of the present study is to evaluate clinical practice in the diagnosis of severe unexplained syncope among European Syncope Units adhering to the standards set forth by the ESC guidelines.
調査の概要
詳細な説明
The Diamond study is an investigator-initiated, prospective, international, multicenter study, coordinated by the non-profit organization Gruppo Italiano Studio Sincope (GIMSI), conducted within European Syncope Units that fulfill the personnel and equipment criteria recommended by the European Heart Rhythm Association (EHRA) and the (GIMSI) (https://www.gimsi.it/modello-organizzativo/).
Eligibility of each center is certified by the head of the syncope unit, who completes a questionnaire confirming compliance with the required standards. Web-based Clinical Report Form (CRF). To allow uniform clinical data collection from participating centres, a web-based CRF, was designed Study workflow. Following documented patient consent, clinical personnel at the site -trained in the use of the web-app- will access the digital tool to enter the patient's I/E criteria assessment, personal information and medical history. From that point forward, data will be entered into the web-app on an ongoing basis, in accordance with the site's routine clinical practice, until the patient reaches a defined exit point (such as diagnosis of cardiac syncope, diagnosis of autonomic syncope, no syncope, no diagnosis), or drop-out (e.g., patient death, patient unable to comply with diagnostic pathway, etc.).
研究の種類
入学 (推定)
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Consecutive patients referred to the Syncope Unit for severe unexplained syncope
説明
Inclusion Criteria: Outpatients aged ≥16 years referred to the Syncope Unit due to severe, unexplained syncope and/or unexplained fall requiring comprehensive evaluation to identify the most appropriate mechanism-specific therapy.
Exclusion Criteria: Non-severe syncope Definitions.
-
Unexplained syncope is defined as unexplained etiology or unexplained
-
Severe syncope is defined by the presence of one or more among the following:
-
Suspected life-threatening arrhythmias
-
Substantial impact on patient's quality of life (QoL)
- Frequent episodes
- Restriction of educational or occupational activities (including, but not limited to, unemployment)
- Restriction of social or daily-life activities, e.g. when syncope occurs while driving
-
High risk of clinically significant outcomes
- Syncope associated with major injuries/trauma, i.e. head injury or fractures
- Unpredictable syncope, i.e. without prodrome or identifiable triggers
-
Presence of serious comorbidities, such as concomitant heart disease, neurologic disease, diabetes or renal failure
-
Suspected Autonomic syncope overlapping with suspected psychogenic pseudosyncope
-
-
Non-severe syncope is defined by the presence of one or more among the following:
- Sporadic (isolated) episodes without major impact on patient's QoL
- Predictable syncope, i.e. syncope preceded by prodrome and/or occurring in association with identifiable triggers, with low risk of injuries
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:PROSPECTIVE
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Unexplained syncope
Syncope Unit |
At the initial evaluation, it is essential to exclude non-syncopal causes of transient loss of consciousness (TLOC) - such as epilepsy, psychogenic pseudosyncope, and other conditions of apparent loss of consciousness that may be incorrectly diagnosed as syncope. Once non-syncopal causes have been excluded and the loss of consciousness is determined to be syncopal in nature, the primary objective of the diagnostic work-up is to identify cases of cardiac syncope. Cardiac syncope is characterized by loss of consciousness due to a primary cardiac disorder, such as arrhythmias or structural heart disease, and requires prompt recognition and appropriate treatment due to its association with higher morbidity and mortality. When both cardiac syncope and non-syncopal causes of TLOC are reasonably ruled out, the diagnosis of autonomic syncope becomes likely. Autonomic syncope encompasses both reflex (neurally mediated) syncope and orthostatic hypotension and represents the most frequent cause |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Rate of final diagnoses 2) Type of final diagnoses 3) Number of tests utilized to reach them.
時間枠:through study completion, an average of 1 year
|
through study completion, an average of 1 year
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Number of participants with adherence of the clinical practices to a theoretical diagnostic pathway
時間枠:through study completion, an average of 1 year
|
through study completion, an average of 1 year
|
|
Assessment of number and costs of resource utilization associated to the clinical practices
時間枠:through study completion, an average of 1 year
|
through study completion, an average of 1 year
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。