Efficacy of Automated Tuina and Acupuncture for Treating Chronic Lower Back Pain
Efficacy of Automated Tuina and Acupuncture for Treating Chronic Lower Back Pain: a Randomized Controlled Study
The goal of this clinical trial is to learn if adding automated robotic Tuina to acupuncture yields a better outcome than acupuncture alone in treating adults with chronic nonspecific low back pain. It will also learn about the safety of the automated robotic Tuina. The main questions it aims to answer are:
Does robotic Tuina and acupuncture reduces score of Visual Analogue Scale (VAS) more than acupuncture alone? Does it improve the sleep, quality of life, pain related impact of participants? Researchers will compare automated robotic Tuina and acupuncture to acupuncture alone if the combination works better to treat chronic nonspecific low back pain.
Participants will:
Receive weekly treatment of either automated robotic Tuina and acupuncture or acupuncture only for 6 sessions over 8 weeks.
Visit the clinic weekly for interventions and test. Wear a sleep tracker ring on the night before and night of treatment to sleep.
調査の概要
詳細な説明
Chronic nonspecific low back pain is a common condition that can affect daily activities and quality of life. Tuina is a traditional Chinese medicine manual therapy that may help relieve pain and improve function. Automated robotic Tuina may offer a more standardized approach to delivering this treatment.
This randomized controlled study aims to evaluate whether adding automated robotic Tuina to acupuncture provides additional benefits for adults with chronic nonspecific low back pain, compared with acupuncture alone.
A total of 56 participants aged 21 to 70 years are planned for recruitment across three study sites in Singapore. Participants will be randomly assigned in a 1:1 ratio to receive either acupuncture alone or acupuncture combined with automated robotic Tuina.
The primary outcome is low back pain intensity measured using a visual analogue scale (VAS). Secondary outcomes include physical disability, pain-related interference, quality of life, sleep-related measures and acceptance of robotic Tuina. Adverse events will also be monitored throughout the study.
The findings may help clarify the additional clinical benefit and safety of automated robotic Tuina when used alongside acupuncture for chronic nonspecific low back pain.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Linda Zhong
- 電話番号:+65 6592 1733
- メール:linda.zhong@ntu.edu.sg
研究連絡先のバックアップ
- 名前:Chin Ee Ho
- 電話番号:+65 84130628
- メール:chinee001@e.ntu.edu.sg
研究場所
-
-
-
Singapore、シンガポール、229469
- 募集
- Novahealth TCM Clinic
-
コンタクト:
- Chin Ee Ho
- 電話番号:+65 84130628
-
Singapore、シンガポール、637551
- 募集
- NTU Chinese Medicine Clinic
-
コンタクト:
- Chin Ee Ho
- メール:chinee001@e.ntu.edu.sg
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adults aged 21 to 70 years.
- At least one primary care visit for back pain within the past 3 to 12 months at either a Chinese medicine or Western medicine clinic.
- Non-specific, uncomplicated low back pain, as specified in the study protocol.
- Able to communicate and write in English and/or Chinese.
Exclusion Criteria:
- Previous acupuncture for back pain within the past 3 months.
- Low back pain lasting less than 3 months.
- Mild symptoms, defined in the protocol as a score below 5 on a 0 to 10 pain bothersomeness scale.
- Specific diseases or pathologies identified as the cause of back pain, including the conditions listed in the study protocol.
- Previous vertebral column or back surgery.
- Disabling chronic conditions that may confound treatment effects or interpretation of the data.
- Contraindications to acupuncture or situations in which its safety has not been confirmed, including clotting disorders, anticoagulant therapy, a cardiac pacemaker, pregnancy or seizure disorder.
- Deemed unfit for acupuncture and/or robotic Tuina by the treating Chinese medicine physician because of the participant's current medical condition.
- Current use of long-term medication for pain management and relief, as specified in the study protocol.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Acupuncture Plus Automated Robotic Tuina
Standard acupuncture treatment followed by Automated Robotic Tuina |
Participants receive 30 minute standard acupuncture and automated robotic Tuina using the EMMA device, according to the study's standardized operating procedures. Robotic Tuina is applied to the lumbosacral region, hips and lower limbs. The protocol describes an approximately 30-minute robotic Tuina treatment, with the applied force adjusted according to participant feedback within the specified range. |
|
アクティブコンパレータ:Acupuncture alone
Standard acupuncture |
Participants receive acupuncture according to the study's standardized treatment protocol. The protocol describes needle retention for 30 minutes and specifies the acupuncture points and procedures to be used. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change from baseline in pain intensity. Visual analogue scale.
時間枠:At baseline, at 8 weeks
|
A 10-point Numerical Pain Scale (0: no pain, 10: maximum pain) assesses the intensity of pain |
At baseline, at 8 weeks
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change from baseline in Roland Morris Disability Questionnaire (RMDQ).
時間枠:At baseline and at 8 weeks
|
This is a self-reported questionnaire consisting in 24 items reflecting limitations in different activities of daily living attributed to low back pain including walking, vending over, sitting, lying down, dressing, sleeping, self-care and daily activities. |
At baseline and at 8 weeks
|
|
Change from baseline in Brief Pain Inventory (BPI)
時間枠:At baseline and at 8 weeks
|
Pain interference was evaluated using the Pain Interference subscale of the Brief Pain Inventory (BPI). The subscale consists of 7 items assessing how much pain disrupts dimensions of daily living. Each item is scored on a 0 to 10 numeric rating scale. The overall score is calculated as the mean of the 7 items, yielding a final score ranging from a minimum of 0 to a maximum of 10. A higher score indicates a worse outcome (greater pain interference with daily functioning). |
At baseline and at 8 weeks
|
|
Change from baseline in WHO-QOL (Brief)
時間枠:At baseline and at 8 weeks
|
Quality of life was evaluated using the World Health Organization Quality of Life-BREF (WHOQOL-BREF). The scale comprises 26 items assessing 4 domains: Physical Health (7 items), Psychological (6 items), Social Relationships (3 items), and Environment (8 items). Domain scores are calculated by summing the respective items and converting them to a transformed scale. For each domain, scores range from a minimum of 0 to a maximum of 100, where a higher score indicates a better outcome (higher quality of life) |
At baseline and at 8 weeks
|
|
Change in objective sleep parameters via wearable smart ring
時間枠:At baseline throughout the 8 weeks, to be tracked the night before and after treatment session.
|
Assessed using Leadtek smart ring worn on the finger. Evaluated parameters include sleep time, overnight heart rate variability and sleep quality from baseline to week 8 |
At baseline throughout the 8 weeks, to be tracked the night before and after treatment session.
|
|
Change in Technology Acceptance Model (TAM) questionnaire from baseline
時間枠:At baseline and at 8 weeks
|
Participant acceptance of automated robotic Tuina, will be measured at baseline and after completion of study covering domains including perceieved usefulness, attitude and behavioural intentions. A 7-point Likert scale was used to measure TAM constructs, where 1 indicated 'strongly disagree' and 7 indicated ' strongly agree'. A higher score reflects better perception of and attitutude towards the technology. |
At baseline and at 8 weeks
|
|
Incidence of Treatment-Emergent Adverse Events [Safety]
時間枠:From start of treatment to end of treatment at week 8
|
Incidence and nature of adverse events during the study. |
From start of treatment to end of treatment at week 8
|
協力者と研究者
捜査官
- 主任研究者:Linda Zhong, Associate Professor、Nanyang Technological University
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Individual participant data will not be made available to external researchers. Participant-level data contain confidential health information and will be managed in accordance with the approved study protocol, informed consent requirements, institutional policies and applicable data-protection requirements. Study findings will be disseminated through appropriate scientific publications and other research outputs.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。