- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT05133375
Hemodynamic Changes of Tracheal Intubation With McCoy and Macintosh Laryngoscopes
Comparison of Hemodynamic Changes of Tracheal Intubation With McCoy and Macintosh Laryngoscopes
연구 개요
상세 설명
After taking approval from hospital ethical committee, 272 patients who reported to Operation Theatre of CMH, Jhelum were selected for the study. Informed consent was obtained and patient demographic information (name, age, contact) was recorded. Patients were randomly divided in two equal groups by using lottery method. GROUP A: Where Macintosh laryngoscope was used for endotracheal intubation. GROUP B: Where McCoy laryngoscope was used for endotracheal intubation.
Before reporting to Operation theatre a detailed pre anesthesia assessment was done in all patients, all necessary laboratory investigations were collected. On OT table pulse and systolic blood pressure was checked by non-invasive method. 18G cannula was passed and ECG was attached. A pillow was placed under the head to obtain classical sniffing position for intubation. All the patients were pre medicated with injection midazolam 0.08mg/kg, injection nalbuphine 0.1 mg/kg, injection dexamethasone 0.08mg/kg and injection metoclopramide 0.1 mg/kg. Pre oxygenation was done with 100% oxygen for 3 mins. Induction was done with injection propofol2 mg/kg, muscle relaxation achieved with injection atracurium 0.5mg/kg. Laryngoscopy was started after 3 minutes by a qualified anesthetist. Pulse and systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3minutes after intubation. All this information was recorded on a Proforma.
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Punjab
-
Jhelum, Punjab, 파키스탄, 49600
- CMH
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Both Male and Female
- Age between 18 to 70
- ASA I and II males and females.
- Malampatti I and II.
- Hemodynamically stable, no known ischemic heart disease and no history of hypertension.
- Nil per oral for at least 6 hours.
Exclusion Criteria:
- Non consenting patient.
- ASA III, IV or V patient.
- Malampati III or IV.
- Cervical instability
- Thyromental distance of less than 6cm, inter incisor distance of less than 3cm.
- Known case of hypertension and ischemic heart disease.
- Pregnant female.
- Body mass index of more than 30.
- Patients of oropharyngeal surgery.
- Unable to Intubate in less than 1 minute.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 다른
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: GROUP A
Macintosh laryngoscope was used for endotracheal intubation.
|
Before reporting to Operation theatre, a detailed pre anesthesia assessment was done in all patients, all necessary laboratory investigations were collected.
On OT table pulse and systolic blood pressure was checked by non-invasive method.
18G cannula was passed and ECG was attached.
A pillow was placed under the head to obtain classical sniffing position for intubation.
All the patients were pre medicated with injection midazolam 0.08mg/kg, injection nalbuphine 0.1 mg/kg, injection dexamethasone 0.08mg/kg and injection metoclopramide 0.1 mg/kg.
Pre oxygenation was done with 100% oxygen for 3 mins.
Induction was done with injection propofol2 mg/kg, muscle relaxation achieved with injection atracurium 0.5mg/kg.
Laryngoscopy was started after 3 minutes by a qualified anesthetist.
Pulse and systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation.
|
|
실험적: GROUP B
McCoy laryngoscope was used for endotracheal intubation.
|
Before reporting to Operation theatre, a detailed pre anesthesia assessment was done in all patients, all necessary laboratory investigations were collected.
On OT table pulse and systolic blood pressure was checked by non-invasive method.
18G cannula was passed and ECG was attached.
A pillow was placed under the head to obtain classical sniffing position for intubation.
All the patients were pre medicated with injection midazolam 0.08mg/kg, injection nalbuphine 0.1 mg/kg, injection dexamethasone 0.08mg/kg and injection metoclopramide 0.1 mg/kg.
Pre oxygenation was done with 100% oxygen for 3 mins.
Induction was done with injection propofol2 mg/kg, muscle relaxation achieved with injection atracurium 0.5mg/kg.
Laryngoscopy was started after 3 minutes by a qualified anesthetist.
Pulse and systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Effect on the pulse of intubation with Macintosh and McCoy laryngoscope
기간: After Laryngoscopy, pulse was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation.
|
To measure hemodynamic changes (i.e.
pulse) of intubation with Macintosh and McCoy laryngoscope
|
After Laryngoscopy, pulse was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation.
|
|
Effect on the systolic blood pressure of intubation with Macintosh and McCoy laryngoscope
기간: After Laryngoscopy, systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation
|
To measure hemodynamic changes (i.e.
systolic blood pressure) of intubation with Macintosh and McCoy
|
After Laryngoscopy, systolic blood pressure was recorded by non-invasive measures before laryngoscopy and at 30 seconds, 2 and 3 minutes after intubation
|
공동 작업자 및 조사자
스폰서
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- 11112021
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .