이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Acute Effects of Exercise Bars on Proprioception, ReactionTime, Power and Upper Extremity Performance (EXBAR-RT)

2026년 5월 10일 업데이트: Beril Demirtas, Aydin Adnan Menderes University

The Effect of Acutely Applied Exercise Bars on Proprioception, Reaction Time, Power and Upper Extremity Performance

This study will be conducted between May and August 2026 at Aydın Adnan Menderes University, Faculty of Health Sciences, with male individuals aged 18-35. For the study, cases will first be divided into 3 groups by computer-assisted randomization.The first group will be the Flex-i bar group, the second group will be the Theraband Flex bar group, and the third group will be the Sham bar group. Group 1 will perform the exercises with the Flex-i bar, while Group 2 will perform them with the Theraband Flex bar. The control group will perform the exercises with a rolling pin.After group assignment of cases is completed, demographic information such as age, height and weight of the participants will be recorded. Then, pre-exercise assessments of the participants will be conducted. The assessment will include proprioception, reaction time, power and upper extremity performance. Following the initial assessment, each group will perform their exercises with their own exercise material. Measurements will be repeated after the exercises. Measurements will be taken three times during the assessments and the best result will be recorded.

연구 개요

상세 설명

This study will be conducted between May and August 2026 at Aydın Adnan Menderes University, Faculty of Health Sciences, with male individuals aged 18-35. For the study, cases will first be divided into 3 groups by computer-assisted randomization.The first group will be the Flex-i bar group, the second group will be the Theraband Flex bar group, and the third group will be the Sham bar group. Group 1 will perform the exercises with the Flex-i bar, while Group 2 will perform them with the Theraband Flex bar. The control group will perform the exercises with a rolling pin.After group assignment of cases is completed, demographic information such as age, height and weight of the participants will be recorded. Then, pre-exercise assessments of the participants will be conducted. The assessment will include proprioception, reaction time, power and upper extremity performance. Following the initial assessment, each group will perform their exercises with their own exercise material. Measurements will be repeated after the exercises. Measurements will be taken three times during the assessments and the best result will be recorded.

Proprioception Measurement (Joint Position Sense): Before starting the test, the content of the test will be explained in detail and a trial will be conducted. For the test, the participant will first be asked to sit in a chair with back support. Then their eyes will be covered with an eye mask. A digital inclinometer will be placed on their wrist with Velcro (Baseline 12-1057 digital inclinometer). The researcher will show the participant the desired degree of movement, and the participant will be asked to do this themselves. Then the test phase will begin, and the individual will be asked to actively reach the target angle. The amount of deviation of the angle reached by the individual will be recorded. This process will be repeated 3 times, and the best value will be used as the analysis value.

Measurement of Reaction Time: The time it takes for a person to give a motor response (e.g., pressing a button, reaching for a light) upon perceiving a visual stimulus will be measured in milliseconds (ms). Simple reaction time tests are performed using complex technical equipment such as infrared lasers, step panels, and motion-based approach models. Portable, wireless light devices such as Blazepod, FitLight Trainer, and Reflexlight are among the current equipment used for reaction time. In this study, the Blazepod reaction time meter will be used. The participant will touch the button on one of four illuminated devices placed on a table, according to the visual stimulus, and turn off the light. The duration of the person pressing the button will be automatically detected by the device and the duration will be recorded.

Upper Extremity Performance Measurement: The Upper Quarter Y Balance Test will be used for performance measurement.

The person assumes a plank position (hands on the ground, feet behind). The supporting arm remains stationary, and the arm being tested is extended in 3 different directions: Medial (inward), superolateral (opposite), and inferolateral (outer diagonal backward).

In each extension, the maximum distance that can be reached with the test arm is measured (cm). 3 repetitions are performed for each direction. The furthest distance (maximum reach) is recorded. The distance reached is normalized according to the upper extremity length.

Power Measurement: Seated Medicine Ball Throw (SMBT); is the most commonly used test. It is used to measure the explosive power of the upper body and arm muscles. The participant sits upright against a wall. They throw a 2-3 kg medicine ball forward from chest height with maximum force. The distance reached is measured (the point of initial contact with the ball). The furthest distance (cm) is recorded.

The Flexi bar is an exercise tool designed by German physiotherapists. It weighs 719 grams and is 1520 mm long. It has a rubber handle in the middle (17.9 cm) and consists of a flexible fiberglass pole with rubber weights at both ends. Due to its elastomer properties and rubber structure, the Flexi-bar is designed to resonate at a frequency of 5 Hz when moving forcefully within the range of motion that needs to be maintained while maintaining physical stability. The desired force to be created in the bar, pulling, and control changes that cause changes in the body or living beings. The working principle is to cause the rubber handle to vibrate at 5 Hz by swinging the bar, and then this vibration is transmitted to the whole body through the arm that is held. For the flex-i bar exercise, the participant will be in a standing position. The movements in different angles and positions will be shown to the participant. Then the flexibar will be given to the participant and they will be asked to hold the exercise bar and swing it correctly in accordance with the desired movements. In flexibar exercises, a 1-minute rest period will be given after each exercise to prevent possible fatigue.

Theraband-Flex Bar is a flexible, durable, and economical exercise equipment made of natural rubber, 30.5 cm long. Its textured surface makes it easy to perform movements and grip. It is available in four colors: Yellow, Red, Green, and Blue. The difficulty levels of the FlexBar vary according to their diameters and colors. It is preferred for increasing grip strength, strengthening the upper extremities, hands, and feet through bending or swinging movements, and effectively providing soft tissue movements. Blue will be preferred for the exercise, and a 1-minute rest period will be given after each exercise.

Rolling pin; a standard size (100cm) rolling pin will be preferred in the control group. 1-minute rest period will be given after each exercise.

Exercises Each exercise will be performed for 30 seconds, followed by a 1-minute rest period.

  1. Swing from side to side with elbow straight
  2. Swing forward and backward with elbow straight
  3. Swing from side to side with elbow bent
  4. Swing forward and backward with elbow bent
  5. Swinging the arm outwards with the elbow straight to the right and left.
  6. Swinging the arm outwards with the elbow straight to the forward and backward.
  7. Swinging the shoulder externally to the right and left.
  8. Swinging the shoulder externally to the forward and backward.

연구 유형

중재적

등록 (추정된)

45

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

  • 이름: Beril Demirtaş, graduted student
  • 전화번호: +905417163955
  • 이메일: berildmrts@gmail.com

연구 장소

      • Aydin, 터키 (Türkiye)
        • Aydın Adnan Menderes Üniversitesi
        • 연락하다:
        • 수석 연구원:
          • Gürkan Günaydın, associate professor

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인

건강한 자원 봉사자를 받아들입니다

예

설명

Inclusion Criteria:

  • Aged between 18 and 35 years
  • Healthy individuals
  • No history of upper extremity injury
  • No neurological disorders
  • Voluntary participation

Exclusion Criteria:

  • Presence of any neurological disease
  • History of upper extremity surgery
  • Current musculoskeletal pain or injury
  • Any condition affecting proprioception or reaction time
  • Inability to comply with study procedures

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 다른
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: A-Flexi bar
For the flexi-bar exercise, the participant will be in a standing position. The participant will be shown movements in different angles and positions. Then, the participant will be given a flexi-bar and asked to hold the exercise bar and swing it correctly according to the desired movements. In flexi-bar exercises, a 1-minute rest period will be given after each exercise to account for possible fatigue.
A single session of oscillatory exercise using a Flexi-Bar applied to the upper extremity.
실험적: B-Theraband Flex-Bar
The participant will be in a standing position. The participant will be shown movements in different angles and positions. They are preferred because they increase grip strength, strengthen the upper extremities, hands and feet with bending or swinging movements, and enable soft tissue movements effectively. Blue color will be preferred for the exercise and a 1-minute rest period will be given after each exercise.
A single session of upper extremity exercise using a Theraband Flex-Bar.
다른: C-Rolling pin
Rolling pin; a standard size (100cm) rolling pin will be used in the control group. A 1-minute rest period will be given after each exercise.
A single session of upper extremity exercise using a rolling pin.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Proprioception
기간: Immediately before and immediately after a single session intervention (within the same day)
Joint position sense will be assessed using an inclinometer.(Baseline 12-1057 digital inclinometer)
Immediately before and immediately after a single session intervention (within the same day)
Reaction Time
기간: Immediately before and immediately after a single session intervention (within the same day)
Reaction time will be measured using a computerized reaction time test.(Blazepod)
Immediately before and immediately after a single session intervention (within the same day)

2차 결과 측정

결과 측정
측정값 설명
기간
Power
기간: Immediately before and immediately after a single session intervention (within the same day)
Muscle power will be assessed using a Single Arm Medicine Ball Throw Test.
Immediately before and immediately after a single session intervention (within the same day)
Upper Extremity Performance
기간: Immediately before and immediately after a single session intervention (within the same day)
Upper extremity performance will be evaluated using a functional performance test.(UQ Y-Balance Test)
Immediately before and immediately after a single session intervention (within the same day)

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

  • Pourahmadi, M.R., et al., Reliability and validity of an iPhone® application for the measurement of lumbar spine flexion and extension range of motion. PeerJ, 2016. 4: p. e2355. Mourcou, Q., et al., Mobile phone-based joint angle measurement for functional assessment and rehabilitation of proprioception. BioMed research international, 2015. 2015. de-Oliveira, L. A., Matos, M. V., Fernandes, I. G., Nascimento, D. A., & da Silva- Grigoletto, M. E. (2021). Test-retest reliability of a visual-cognitive technology (BlazePod™) to measure response time. Journal of sports science & medicine, 20(1), 179. van der Leeuw, G., Eggermont, L. H. P., Shi, L., Milberg, W. P., Gross, A. Hausdorff, J. M., ... ve Lipsitz, L. A. (2016). Pain and cognitive function among older adults living in the community. The Journals of Gerontology: Series A, 71(3), 398-405. Ruffe, N. J., Sorce, S. R., Rosenthal, M. D., ve Rauh, M. J. (2019). Lower quarter- and upper quarter Y balance tests as predictors of running-related injuries in high school cross-country runners. International Journal of Sports Physical Therapy, 14(5), 695-706. Wang, D., Gibbons, M., Shung, J., ve Hame, S. (2016). Functional testing and return to sport after ACL reconstruction. Current Reviews in Musculoskeletal Medicine, 9(3), 330-336. Mischi, M., & Cardinale, M. (2009). The effects of a 28-Hz vibration on arm muscle activity during isometric exercise. Medicine & Science in Sports & Exercise, 41(3), 645-653 Escamilla, R.F., et al., An electromyographic analysis of the shoulder complex musculature while performing exercises using the bodyblade® classic and bodyblade® pro. International Journal of Sports Physical Therapy, 2016. 11(2): p. 175. de Lima Boarati, E., et al., Acute effect of flexible bar exercise on scapulothoracic muscles activation, on isometric shoulder abduction force and proprioception of the shoulder of individuals with and without subacromial pain syndrome.Clinical Biomechanics, 2020.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 5월 1일

기본 완료 (추정된)

2026년 8월 1일

연구 완료 (추정된)

2026년 8월 1일

연구 등록 날짜

최초 제출

2026년 4월 12일

QC 기준을 충족하는 최초 제출

2026년 5월 3일

처음 게시됨 (실제)

2026년 5월 8일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 5월 13일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 5월 10일

마지막으로 확인됨

2026년 5월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • ADU-FTR-BD-01

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

예

IPD 계획 설명

Study results will be shared

IPD 공유 기간

From May 2026-August 2026

IPD 공유 지원 정보 유형

  • 연구_프로토콜
  • CSR

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다