이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Deep Learning for Early Scoliosis Detection Using mmWave Radar Gait Data (ScoliRadar-AI)

2026년 5월 12일 업데이트: Zehra Bilici, Gebze Technical University

A Deep Learning-Based Approach for Early Scoliosis Detection Using mmWave Radar-Based Gait Data

Scoliosis is a sideways curvature of the spine that often develops during childhood and adolescence. When detected early, scoliosis can be managed effectively with non-invasive approaches such as bracing and physiotherapy, while late detection frequently leads to surgical intervention. Current screening methods rely on physical examination and X-ray imaging, which exposes children to ionizing radiation and may miss early-stage cases.

This observational study investigates whether millimeter-wave (mmWave) radar, combined with deep learning (a type of artificial intelligence), can detect early signs of scoliosis by analyzing how a child walks. The radar sensor records subtle movement patterns during walking without using cameras and without producing any identifiable images, fully preserving the participant's privacy. No ionizing radiation is involved.

Pediatric participants attending the orthopedic clinic for routine scoliosis evaluation are invited to walk a short distance in front of a mmWave radar sensor. The collected gait recordings are then analyzed using deep learning models, and the results are compared with the participant's standard clinical scoliosis assessment performed by a pediatric orthopedic specialist. The diagnostic performance of the deep learning model is evaluated using sensitivity, specificity, and overall accuracy.

If the approach proves accurate, it could offer a radiation-free, privacy-preserving, and low-cost alternative for early scoliosis screening in schools, primary healthcare centers, and pediatric orthopedic clinics, ultimately supporting earlier diagnosis and reducing the long-term clinical burden of untreated scoliosis.

연구 개요

상세 설명

Background:

Adolescent Idiopathic Scoliosis (AIS) is the most common form of spinal deformity in children, affecting approximately 2-4% of adolescents worldwide. Early detection is critical because mild curves can often be managed conservatively (bracing, targeted physiotherapy), whereas advanced curves frequently require surgical correction. Current screening primarily relies on physical examination (forward bend test, scoliometer) supplemented by radiographic confirmation. These methods have known limitations: physical examination has variable sensitivity and inter-observer reliability, while repeated radiographic follow-up exposes pediatric patients to cumulative ionizing radiation. Camera-based motion analysis systems have been proposed as alternatives but raise significant privacy concerns in pediatric populations.

Rationale:

Millimeter-wave (mmWave) radar is a non-ionizing, contactless sensing technology that captures fine-grained motion signatures without producing identifiable visual images. Recent advances in deep learning have demonstrated promising results in interpreting radar-derived gait signals for biomechanical analysis. The investigators hypothesize that subtle biomechanical asymmetries associated with early scoliosis can be detected from mmWave radar gait recordings using appropriately trained deep learning models, providing a privacy-preserving and radiation-free screening modality.

Primary Objective:

To develop and evaluate the diagnostic accuracy of a deep learning model that classifies pediatric participants as having scoliosis or not based on mmWave radar gait data, measured by sensitivity, specificity, and area under the receiver operating characteristic curve (AUC-ROC).

Secondary Objectives:

  1. To compare diagnostic performance across multiple deep learning architectures (including convolutional neural networks, recurrent neural networks, and transformer-based models).
  2. To evaluate model performance stratified by age, sex, and curve severity (Cobb angle category).
  3. To assess test-retest reliability of radar-derived gait features.

Study Design:

This is a single-center, prospective, observational diagnostic accuracy study. Pediatric participants undergoing routine scoliosis evaluation at the participating center are invited to take part. Each participant performs a standardized walking task along a defined path in front of a mmWave radar sensor. Radar recordings are processed and analyzed using deep learning models. Model outputs are compared against the reference standard.

Reference Standard:

Scoliosis status is established by a pediatric orthopedic specialist based on clinical examination supplemented by Cobb angle measurement from existing standard-of-care radiographic data. No additional radiographic imaging is performed for the purpose of this study.

Data Handling and Privacy:

All radar recordings and clinical data are de-identified at the point of collection and stored on institutional servers in compliance with the Turkish Personal Data Protection Law (Law No. 6698, KVKK) and the Regulation on Personal Health Data. Data access is restricted to authorized study personnel. No identifiable visual images are recorded by the mmWave radar sensor.

연구 유형

관찰

등록 (추정된)

200

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

  • 이름: Ercan Ayaz, Doç Dr.

연구 장소

    • Istanbul
      • Istanbul, Istanbul, 터키 (Türkiye), 34480
        • Başakşehir Çam and Sakura City Hospital
        • 연락하다:
        • 연락하다:
          • Ercan Ayaz, Doç. Dr.

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 어린이
  • 성인
  • 고령자

건강한 자원 봉사자를 받아들입니다

예

샘플링 방법

비확률 샘플

연구 인구

Pediatric and adolescent participants attending the pediatric orthopedic outpatient clinic at Başakşehir Çam and Sakura City Hospital for routine scoliosis evaluation. Consecutive eligible patients are invited to participate, including both those with confirmed scoliosis and those in whom scoliosis is ruled out following clinical and radiographic assessment.

설명

Participation Criteria:

  • Being between 2 and 75 years of age at the time of registration
  • Having applied to the pediatric orthopedics outpatient clinic for an assessment of suspected or known scoliosis
  • Being able to walk independently for at least 7 meters without assistive devices
  • Written informed consent from a parent or legal guardian
  • Written informed consent from the participant

Exclusion Criteria:

  • Severe scoliosis requiring urgent surgical intervention that prevents participation in walking tasks
  • Refusal to give informed consent or consent

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
Pediatric Participants Undergoing Scoliosis Evaluation
Consecutive pediatric participants attending the orthopedic outpatient clinic for routine scoliosis evaluation. The cohort includes participants across the full spectrum of clinical assessment outcomes (both scoliosis confirmed and scoliosis ruled out) to enable evaluation of the diagnostic accuracy of the mmWave radar-based deep learning model against the standard-of-care clinical and radiographic reference assessment.
Each participant performs a standardized walking task along a defined path in front of a millimeter-wave (mmWave) radar sensor. The radar continuously records the participant's gait micro-Doppler signatures during the walk. The mmWave radar device is contactless, non-ionizing, and does not capture identifiable visual images, fully preserving participant privacy. The recorded gait signals are subsequently processed and analyzed using deep learning models (including convolutional and transformer-based architectures) trained to classify scoliosis status. The full radar-based assessment takes approximately 5 to 10 minutes per participant. The standard clinical and radiographic scoliosis evaluation performed as part of routine care serves as the reference standard.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Diagnostic Accuracy of the mmWave Radar-Based Deep Learning Model for Scoliosis Detection (AUC-ROC)
기간: Assessed at the end of the data collection period, approximately 18 months after study start
The diagnostic performance of the mmWave radar-based deep learning classification model is assessed by the area under the receiver operating characteristic curve (AUC-ROC). The AUC-ROC is computed by comparing the model's predicted probability of scoliosis for each participant against the reference standard (clinical examination combined with Cobb angle measurement from standard-of-care radiographic imaging) on a held-out test set. The AUC-ROC is reported as a single numeric value between 0 and 1, with 95% confidence intervals.
Assessed at the end of the data collection period, approximately 18 months after study start

2차 결과 측정

결과 측정
측정값 설명
기간
Sensitivity and Specificity of the Deep Learning Model at the Optimal Operating Point
기간: Assessed at the end of the data collection period, approximately 18 months after study start
At the operating point that maximizes the Youden index on the validation set, the sensitivity (true positive rate) and specificity (true negative rate) of the deep learning model for classifying scoliosis status are calculated on the held-out test set. Both metrics are reported as percentages with 95% confidence intervals.
Assessed at the end of the data collection period, approximately 18 months after study start
Comparative Diagnostic Performance Across Deep Learning Architectures
기간: Assessed at the end of the data collection period, approximately 18 months after study start
The diagnostic accuracy (AUC-ROC) of multiple deep learning architectures, including convolutional neural networks (CNN), recurrent neural networks (RNN/LSTM), and transformer-based models, is compared on the same dataset using cross-validation. The architecture yielding the highest AUC-ROC is identified as the best-performing model.
Assessed at the end of the data collection period, approximately 18 months after study start
Stratified Diagnostic Performance by Scoliosis Severity (Cobb Angle Category)
기간: Assessed at the end of the data collection period, approximately 18 months after study start
The diagnostic accuracy of the deep learning model is evaluated separately for participants with mild scoliosis (Cobb angle 10 to 24 degrees), moderate scoliosis (Cobb angle 25 to 39 degrees), and severe scoliosis (Cobb angle 40 degrees or greater). Sensitivity is reported for each severity category to assess whether the model detects clinically significant curves of different magnitudes.
Assessed at the end of the data collection period, approximately 18 months after study start

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 6월 1일

기본 완료 (추정된)

2027년 12월 1일

연구 완료 (추정된)

2028년 6월 1일

연구 등록 날짜

최초 제출

2026년 5월 12일

QC 기준을 충족하는 최초 제출

2026년 5월 12일

처음 게시됨 (실제)

2026년 5월 18일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 5월 18일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 5월 12일

마지막으로 확인됨

2026년 5월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

IPD 계획 설명

Individual participant data will not be shared. The dataset consists of biometric gait signatures from minors, classified as personal health data under the Turkish Personal Data Protection Law (Law No. 6698, KVKK) and the Regulation on Personal Health Data. Sharing is restricted by national legislation and institutional policy. De-identified aggregated results will be published in peer-reviewed scientific journals.

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .