- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07639541
Radio-frequency (RF) Bladder Monitor
The goal of this pilot feasibility study is to evaluate a wearable microwave (MW)-based bladder monitoring system in adult volunteers and those with spinal cord injury (SCI) who use self-catheterization for bladder management. The study aims to learn whether the device can monitor bladder filling and estimate bladder volume non-invasively.
The main questions the study aims to answer are:
- Can the MW-based monitoring system distinguish between non-full and full bladder states?
- How accurately do MW-based bladder volume estimates agree with ultrasound bladder scans and voided urine volumes?
- Is the wearable monitoring system feasible, comfortable, and usable for individuals with SCI?
Participants will:
- Complete questionnaires about bladder symptoms and quality of life
- Wear up to six non-invasive MW sensors on the lower pelvic region
- Undergo two bladder filling and voiding cycles during the study visit
- Have MW measurements collected approximately every five minutes during bladder filling
- Undergo ultrasound bladder scans and bladder volume measurements for comparison
- Complete a post-study usability and comfort survey
연구 개요
상태
상세 설명
Spinal cord injury (SCI) presents significant long-term challenges for affected individuals, among which bladder dysfunction is a leading concern. Neurogenic lower urinary tract dysfunction (NLUTD), commonly referred to as neurogenic bladder dysfunction, may result in urinary retention, incomplete bladder emptying, urinary incontinence, urinary tract infections (UTIs), bladder distension, urinary reflux, renal complications, and reduced quality of life. Current bladder management approaches, including clean intermittent catheterization (CIC), indwelling catheterization, and external collection methods, may be associated with substantial time burden, complications, excessive bladder filling or incomplete emptying, and poor adherence. Studies have also shown that improving bladder function remains one of the highest rehabilitation priorities among individuals with SCI.
This study investigates the feasibility of a wearable radio-frequency (RF)-based bladder monitor operating in the microwave (MW) frequency range for non-invasive bladder monitoring and bladder volume estimation. The proposed system is intended to measure and track bladder volume and may ultimately support future development of discreet alerts indicating when the bladder is appropriately full and it is time to void. RF/MW sensing approaches provide several potential advantages for bladder monitoring applications because they are non-invasive, low-cost, safe for repeated use within established exposure limits, and compatible with wearable device designs.
Previous computational and experimental studies investigating RF/MW approaches for bladder-state detection have demonstrated proof-of-concept feasibility; however, many earlier studies relied on simplified anatomical models and limited experimental conditions. More recent work by the investigators demonstrated bladder-state discrimination using realistic anatomical pelvic models and preliminary measurements in healthy volunteers. This study includes measurements in both healthy volunteers and individuals with SCI who self-catheterize.
The objectives of the study are:
i) to provide a clinical proof-of-concept demonstration of MW bladder monitoring and bladder volume quantification; and ii) to provide data regarding the short-term functionality, utility, and comfort of the wearable MW bladder monitoring prototype.
The study will enroll adult healthy volunteers and adult participants with SCI who use self-catheterization for bladder management. Following informed consent, participants with SCI may complete questionnaires related to bladder dysfunction and bladder-related quality of life, including the Neurogenic Bladder Symptom Score Short Form (NBSS-SF).
Participants will undergo bladder filling and voiding cycles during the study visit. At the beginning of the session, participants will be asked to void their bladder using their usual voiding or catheterization method. For participants in whom pregnancy is possible, urine pregnancy testing may be performed prior to RF measurements. Ultrasound bladder scans will be performed at empty and full bladder states and will serve as reference measurements for bladder volume estimation. Voided urine volumes will also be collected during voiding phases.
The MW bladder monitoring prototype will be placed externally on the lower pelvic region by study personnel. Up to six sensors may be used. Sensors will be secured using adhesive bandages or wrap-style fixation methods. No skin preparation, gels, or invasive procedures are required. MW measurements will be collected automatically approximately every five minutes while the bladder fills naturally. Participants may rest or perform sedentary activities during the measurement period. Measurements will continue until bladder fullness is reached or the participant requests to void. The bladder filling and emptying process may then be repeated for a second cycle during the same study visit.
Collected MW measurement data will be analyzed to investigate signal trends and the feasibility of the technology. Planned analyses include:
- Bladder fullness classification through comparison of MW signal trends between non-full and full bladder states;
- Bladder volume quantification using raw measurement data and reconstructed radar image data;
- Comparison of MW-based bladder volume estimates with ultrasound-estimated bladder volumes and voided urine volumes.
Exploratory analyses will evaluate signal trends across the measured frequency range to select optimal frequency points, measurement variability, and sex-based differences in MW measurements. Participant and clinician feedback surveys will additionally be used to assess device comfort, usability, and utility for bladder monitoring applications.
As a final remark, this pilot feasibility study is intended to generate preliminary clinical data supporting further development and optimization of wearable MW bladder monitoring technology and may support future larger clinical investigations aimed at improving bladder management for individuals living with bladder dysfunction, including neurogenic bladder associated with SCI. The investigational device is considered low risk. The device is non-invasive and uses low-power RF/MW signals for sensing and monitoring purposes only.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Emily Porter, Ph.D.
- 전화번호: 37794 514-934-1934
- 이메일: emily.porter@mcgill.ca
연구 연락처 백업
- 이름: Lysanne Campeau, Ph.D.
- 전화번호: 24906 514-340-8222
- 이메일: lysanne.campeau@mcgill.ca
연구 장소
-
-
Quebec
-
Montreal, Quebec, 캐나다, H4A 3J1
- Centre for Innovative Medicine (CIM) - McGill University Health Centre (MUHC)
-
연락하다:
- Emily Porter, Ph.D.
- 전화번호: 37794 514-934-1934
- 이메일: emily.porter@mcgill.ca
-
수석 연구원:
- Emily Porter, Ph.D.
-
수석 연구원:
- Lysanne Campeau, Ph.D.
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Age > 18
- Able/willing to sit (or stand) in place for the time it takes for bladder to fill once.
- No implanted devices
- Able to toilet/void independently
- No pregnancy
Exclusion Criteria:
- Age < 18
- Implanted devices (e.g., pacemakers)
- Unable to toilet without assistance
- Unable to stay relatively still for the time it takes bladder to fill once
- Pregnancy
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 다른
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Microwave Bladder Monitoring in Individuals with Spinal Cord Injury
Healthy participants and participants with spinal cord injury (SCI) who use self-catheterization for bladder management will undergo non-invasive microwave (MW)-based bladder monitoring during two bladder filling and voiding cycles.
Up to six externally applied MW sensors will be positioned over the lower pelvic region to collect measurements associated with bladder filling.
Measurements will be acquired approximately every five minutes while the bladder fills naturally.
Ultrasound bladder scans and voided urine volumes will be used as reference measurements for bladder volume estimation and bladder fullness assessment.
The study will evaluate the feasibility, usability, comfort, and preliminary performance of the wearable MW bladder monitoring system in both healthy participants and individuals with SCI.
|
The investigational device is a non-invasive wearable microwave (MW) bladder monitoring system designed to monitor bladder filling and estimate bladder volume.
The system uses low-power radio-frequency (RF) signals and externally applied sensors positioned over the lower pelvic region to collect electromagnetic measurements associated with bladder filling.
Measurements will be collected approximately every five minutes during natural bladder filling cycles.
The device is intended for investigational use only and does not provide therapeutic intervention or automated clinical decision-making.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Mean difference in microwave S-parameter magnitude between full and empty bladder states (dB)
기간: Through study completion, an average of 4-8 hours
|
Microwave S-parameter measurements collected during bladder filling and voiding cycles will be compared between empty and full bladder states.
The outcome will be reported as the mean difference and standard deviation in S-parameter magnitude between full and empty bladder states across the measured frequency range, expressed in decibels (dB).
|
Through study completion, an average of 4-8 hours
|
|
Mean error of microwave-based bladder volume estimation (mL) relative to ultrasound bladder volume estimates and voided urine volume
기간: Through study completion, an average of 4-8 hours
|
Bladder volume estimates derived from microwave S-parameter measurements will be compared with ultrasound bladder volume estimates and voided urine volumes obtained during bladder filling and voiding cycles.
The outcome will be reported as the mean difference and standard deviation between microwave-based bladder volume estimates and the corresponding reference measurements (mL).
|
Through study completion, an average of 4-8 hours
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Total score on the investigator-developed post-participation bladder monitor questionnaire
기간: Day 1
|
Participant perceptions of comfort, usability, and utility of the wearable microwave-based bladder monitoring system will be assessed using an investigator-developed post-participation questionnaire.
Total scores range from 1 to 10, with higher scores indicating greater comfort, usability, and perceived utility of the device.
|
Day 1
|
|
Frequency points exhibiting the greatest difference in microwave S-parameter magnitude between full and empty bladder states (MHz)
기간: Through study completion, an average of 4-8 hours
|
For each participant, differences in microwave S-parameter magnitude between full and empty bladder states will be calculated across the 500-3000 MHz frequency range.
The outcome will identify the frequency points and frequency ranges exhibiting the largest bladder-state-dependent signal differences.
Analyses will be performed for the overall cohort and separately for male and female participants to assess sex-based differences in optimal frequency selection.
|
Through study completion, an average of 4-8 hours
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Emily Porter, Ph.D., McGill University
- 수석 연구원: Lysanne Campeau, Ph.D., McGill University
간행물 및 유용한 링크
일반 간행물
- A. Farshkaran and E. Porter, "Importance of Sex-Based Modelling of the Pelvic Region for Microwave Medical Applications," 2022 IEEE MTT-S International Microwave Biomedical Conference (IMBioC), Suzhou, China, 2022, pp. 1-3, doi: 10.1109/IMBioC52515.2022.9790287. keywords: {Microwave technology;Biomedical equipment;Biological system modeling;Conferences;Scattering;Medical services;Physiology;bladder;microwave medical applications;pelvic region}
- A. Raterink, A. Farshkaran and E. Porter, "Microwave Reflection-based Bladder State Discrimination with Realistic Pelvic Models: Impact of Urine Conductivity and Volume," 2021 IEEE MTT-S International Microwave and RF Conference (IMARC), KANPUR, India, 2021, pp. 1-4, doi: 10.1109/IMaRC49196.2021.9714587. keywords: {Microwave antennas;Solid modeling;Shape;Bladder;Conductivity;Microwave theory and techniques;Dielectrics;bladder;microwave imaging;pelvic region model.}
- E. Porter, A. Raterink and A. Farshkaran, "Microwave-Based Detection of the Bladder State as a Support Tool for Urinary Incontinence [Bioelectromagnetics]," in IEEE Antennas and Propagation Magazine, vol. 64, no. 1, pp. 112-122, Feb. 2022, doi: 10.1109/MAP.2021.3129687. keywords: {Wireless communication;Ultrasonic imaging;Magnetic resonance imaging;Computed tomography;Wearable computers;Microwave devices;Monitoring}
- Farshkaran A, Fry A, Raterink A, Santorelli A, Porter E. Proof-of-Concept of Microwave-Based Bladder State Detection Using Realistic Pelvic Models. IEEE Open J Eng Med Biol. 2023 Aug 16;5:140-147. doi: 10.1109/OJEMB.2023.3305838. eCollection 2024.
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
추가 관련 MeSH 약관
기타 연구 ID 번호
- 2025-10205
- CDMRP-SC240005 (기타 보조금/기금 번호: CDMRP)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .