- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07646730
Wearable Device-Based Early Warning of Postoperative Complications in Thoracic Surgery (wearable)
Development and Validation of a Wearable Device-Based Early Warning Model for Postoperative Complications in Thoracic Surgery: A Retrospective and Prospective Cohort Study
After thoracic surgery, some patients may develop complications such as lung infection, abnormal heart rhythm, fluid around the lung, prolonged air leak, wound infection, emergency department visits, or hospital readmission. These problems may not be found early if monitoring is only done during routine vital sign checks or follow-up visits.
This study will evaluate whether data collected by a wearable device can help identify early warning signs of postoperative complications in patients undergoing thoracic surgery. The wearable device will collect information such as heart rate, oxygen level, skin temperature, physical activity, sleep, and wearing status.
The study includes two parts. First, the researchers will review previously collected wearable device and medical record data to develop an early warning model. Second, new patients undergoing thoracic surgery will wear the device from hospital admission until about 30 days after discharge. The model will then be tested to see how well it predicts complications that require medical intervention within 30 days after surgery.
The main goal is to evaluate how accurately the wearable device-based model can identify patients who develop postoperative complications and how early the model can provide a warning before the complication is clinically confirmed.
연구 개요
상태
상세 설명
Postoperative complications are an important concern after thoracic surgery. Conventional perioperative monitoring mainly relies on intermittent vital sign measurements, nursing assessments, physician rounds, and routine post-discharge follow-up. This approach may miss short-lasting, nighttime, or activity-related physiological changes that occur before a complication becomes clinically apparent.
Wearable devices can continuously collect physiological and behavioral information, including heart rate, oxygen saturation, skin temperature, activity, sleep, and wearing status. Combining these data with electronic medical record information may help identify early changes associated with postoperative complications.
This study uses a retrospective and prospective cohort design. In the retrospective stage, previously collected wearable device data and electronic medical record data from thoracic surgery patients will be analyzed. The researchers will evaluate the agreement between wearable device measurements and routine clinical vital signs, describe physiological signal patterns before postoperative complications, and develop a preliminary early warning model.
In the prospective validation stage, newly enrolled patients scheduled for thoracic surgery will wear the study wearable device from hospital admission to approximately 30 days after discharge. The early warning model developed from the retrospective data will be applied prospectively using predefined parameters. Model-generated warnings will be recorded. The occurrence of postoperative complications will be verified through inpatient medical records and follow-up after discharge.
The primary reference outcome is postoperative complications requiring medical intervention within 30 days after surgery. These complications may include pulmonary infection, pleural effusion requiring treatment, prolonged air leak, wound infection, postoperative arrhythmia, emergency department visit, or readmission. Model performance will be evaluated using sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and warning lead time. Wearable device adherence, data completeness, and the added predictive value of wearable device-derived features beyond routine clinical variables will also be assessed.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: Ni Zhang, MD
- 전화번호: +86-27-83665369
- 이메일: nizhang@tjh.tjmu.edu.cn
연구 장소
-
-
Hubei
-
Wuhan, Hubei, 중국, 430030
- 모병
- Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology
-
연락하다:
- Ni Zhang, MD
- 전화번호: +86-27-83665369
- 이메일: nizhang@tjh.tjmu.edu.cn
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Age 18 years or older.
- Hospitalized in the Department of Thoracic Surgery of Tongji Hospital and scheduled to undergo thoracic surgery.
- Able to wear the study-designated wearable device after hospital admission and expected to continue wearing the device and/or uploading data within 30 days after discharge.
Exclusion Criteria:
- Patients or family members are unwilling to wear the wearable device or unable to meet the required wearing time.
- Severe or unstable psychiatric disease, such as severe depression or schizophrenia.
- Pregnancy or lactation.
- Allergy to the watch strap material or local skin conditions that prevent wearing the device.
- Unable to complete follow-up within 30 days after discharge.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
Retrospective Cohort
Patients who previously underwent thoracic surgery and had available wearable device data and electronic medical record data during the perioperative period.
This cohort will be used to evaluate agreement between wearable device measurements and routine clinical vital signs, analyze physiological signal trajectories before postoperative complications, and develop a preliminary early warning model.
|
Participants will wear a study wearable device that continuously collects physiological and behavioral data, including heart rate, oxygen saturation, skin temperature, activity, sleep, and wearing status, from hospital admission to approximately 30 days after discharge.
The device is used for monitoring and data collection and does not change routine clinical care.
|
|
Prospective Validation Cohort
Newly enrolled patients scheduled for thoracic surgery who will wear the study wearable device from hospital admission to approximately 30 days after discharge.
This cohort will be used to prospectively validate the wearable device-based early warning model for postoperative complications within 30 days after surgery.
|
Participants will wear a study wearable device that continuously collects physiological and behavioral data, including heart rate, oxygen saturation, skin temperature, activity, sleep, and wearing status, from hospital admission to approximately 30 days after discharge.
The device is used for monitoring and data collection and does not change routine clinical care.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Area under the receiver operating characteristic curve of the wearable device-based early warning model for 30-day postoperative complications
기간: From the day of surgery to 30 days after surgery
|
The area under the receiver operating characteristic curve will be used to evaluate the ability of the wearable device-based early warning model to distinguish participants who develop postoperative complications requiring medical intervention within 30 days after surgery from those who do not.
Postoperative complications may include pulmonary infection, pleural effusion requiring treatment, prolonged air leak, wound infection, postoperative arrhythmia, emergency department visit, or hospital readmission.
|
From the day of surgery to 30 days after surgery
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Warning lead time before clinically confirmed postoperative complications
기간: From the day of surgery to 30 days after surgery
|
Warning lead time will be defined as the time interval between the first model-generated warning signal and the clinical confirmation of a postoperative complication requiring medical intervention.
|
From the day of surgery to 30 days after surgery
|
|
Sensitivity of the wearable device-based early warning model for 30-day postoperative complications
기간: From the day of surgery to 30 days after surgery
|
Sensitivity will be defined as the proportion of participants with postoperative complications requiring medical intervention within 30 days after surgery who are correctly identified by the wearable device-based early warning model.
|
From the day of surgery to 30 days after surgery
|
|
Specificity of the wearable device-based early warning model for 30-day postoperative complications
기간: From the day of surgery to 30 days after surgery
|
Specificity will be defined as the proportion of participants without postoperative complications requiring medical intervention within 30 days after surgery who are correctly classified as not having a warning signal by the wearable device-based early warning model.
|
From the day of surgery to 30 days after surgery
|
공동 작업자 및 조사자
스폰서
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- TJ-IRB202512090 (기타 식별자: Medical Ethics Committee of Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
IPD 계획 설명
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .