이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Smartphone Accelerometry for Gait Analysis in Children With Unilateral Spastic Cerebral Palsy

2026년 7월 24일 업데이트: Deraya University

Concurrent Validity and Test-Retest Reliability of Smartphone-Embedded Accelerometry for Spatiotemporal Gait Analysis in Children With Unilateral Spastic Cerebral Palsy

This observational study will evaluate whether a smartphone's built-in accelerometer can provide accurate and repeatable measurements of walking in children with unilateral spastic cerebral palsy.

Thirty-five children aged 6 to 12 years will complete two walking trials along a 10-meter indoor walkway at their usual comfortable speed. During each trial, a smartphone will be secured over the lower back at the L4-L5 level to record body acceleration using the Phyphox application. At the same time, a video camera will record the child's walking for analysis using Kinovea software.

Measurements obtained from the smartphone will be compared with measurements obtained from video analysis. The study will assess walking velocity, cadence, stride timing, and gait asymmetry. The two repeated walking trials will also be used to determine whether the smartphone measurements are consistent when the test is repeated during the same session.

The study does not involve any treatment or change to the child's usual medical or physical therapy care. The purpose is to determine whether smartphone-based gait assessment may be a practical, low-cost method for evaluating walking in children with unilateral spastic cerebral palsy.

연구 개요

상세 설명

Children with unilateral spastic cerebral palsy may have differences in walking speed, step timing, cadence, and symmetry between the affected and unaffected lower limbs. Instrumented gait laboratories can provide detailed gait measurements, but they may be expensive, time-consuming, or unavailable in many clinical settings. Smartphones contain built-in motion sensors that may offer a simpler and more accessible method of measuring gait.

This methodological validation study will examine the concurrent validity and intra-session test-retest reliability of smartphone-embedded linear accelerometry for the assessment of spatiotemporal gait parameters in children with unilateral spastic cerebral palsy.

A convenience sample of 35 children will be recruited from the Deraya University outpatient clinic. Eligible participants will be 6 to 12 years of age, have a clinical diagnosis of unilateral spastic cerebral palsy, and be classified as Gross Motor Function Classification System level I or II.

Each participant will attend one assessment session. A Samsung Galaxy A7 smartphone will be secured horizontally over the lower back at the L4-L5 vertebral level using an adjustable waist belt. This location is intended to approximate the body's center of mass. The smartphone's internal linear accelerometer will record movement data using the Phyphox application.

Participants will walk at a comfortable, self-selected speed along a flat, unobstructed 10-meter indoor walkway. At the same time, a high-definition video camera mounted on a stable tripod will record the walking trial from a perpendicular distance of approximately 3 meters. The video recordings will be analyzed frame by frame using Kinovea software and will serve as the reference method.

Each child will complete two identical walking trials during the same session. The trials will be separated by a seated rest period of approximately 5 to 10 minutes to reduce fatigue. No therapeutic intervention will be administered, and the child's usual medical or physical therapy care will not be changed.

Data obtained from the smartphone accelerometer and the video analysis will be used to calculate walking velocity, cadence, stride timing, and gait asymmetry. Smartphone-derived measurements will be compared with the corresponding Kinovea-derived measurements to evaluate concurrent validity. Measurements from the first and second walking trials will also be compared to evaluate intra-session test-retest reliability.

The study is intended to determine whether smartphone-based accelerometry can provide valid and repeatable gait measurements that may be useful as a practical, non-invasive, and low-cost clinical assessment method for children with unilateral spastic cerebral palsy.

연구 유형

관찰

등록 (추정된)

35

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 장소

    • Menia Governorate
      • Minya, Menia Governorate, 이집트
        • 모병
        • Deraya university, faculty of pharmacy
        • 연락하다:

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 어린이

건강한 자원 봉사자를 받아들입니다

아니

샘플링 방법

비확률 샘플

연구 인구

A convenience sample of children aged 6 to 12 years with a clinical diagnosis of unilateral spastic cerebral palsy will be recruited from the Deraya University outpatient clinic. Eligible participants will be classified as Gross Motor Function Classification System level I or II and must be able to walk independently for 10 meters without physical assistance or handheld mobility aids. Participants must also be able to understand and follow simple verbal instructions required for gait assessment.

설명

Inclusion criteria:

  1. Clinical diagnosis of unilateral spastic cerebral palsy.
  2. Chronological age ranging from 6 to 12 years.
  3. Gross Motor Function Classification System (GMFCS) Level I or II (capable of walking 10 meters independently without physical support or handheld mobility aids).
  4. Ability to comprehend and execute simple verbal instructions during clinical evaluation.

Exclusion criteria:

  1. History of lower extremity corrective orthopedic surgery or joint casting within the preceding 12 months.
  2. Botulinum Toxin Type A injections administered to the lower limbs within the past 6 months.
  3. Fixed structural bony deformities or rigid joint contractures in the lower extremities.
  4. Severe, uncorrected visual or auditory deficits that threaten safety or test execution

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
Children With Unilateral Spastic Cerebral Palsy
A convenience sample of 35 children aged 6 to 12 years with unilateral spastic cerebral palsy and Gross Motor Function Classification System levels I or II. All participants will complete two 10-meter walking trials while smartphone accelerometry and simultaneous 2-dimensional video gait analysis are performed. No treatment will be assigned or modified.
A Samsung Galaxy A7 smartphone will be secured horizontally over the participant's lower back at the L4-L5 vertebral level using an adjustable waist belt. The smartphone's built-in linear accelerometer and the Phyphox application will record movement during two 10-meter walking trials performed at a comfortable, self-selected speed. Simultaneous video recordings will be analyzed using Kinovea software as the reference method. Walking velocity, cadence, stride timing, and gait asymmetry will be calculated. The two trials will be separated by a seated rest period of 5 to 10 minutes.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Walking Velocity Measured by Smartphone Accelerometry
기간: Baseline
Walking velocity, expressed in meters per second, will be calculated by dividing the 10-meter walking distance by the time required to complete the walkway. Velocity derived from smartphone linear accelerometry using the Phyphox application will be compared with velocity obtained from frame-by-frame 2-dimensional video analysis using Kinovea software.
Baseline
Cadence Measured by Smartphone Accelerometry
기간: Baseline
Cadence, expressed as steps per minute, will be calculated from acceleration peak intervals recorded by the smartphone using the Phyphox application. Smartphone-derived cadence will be compared with cadence determined by visual frame-by-frame analysis of the simultaneous Kinovea video recording.
Baseline
Gait Asymmetry Index
기간: Baseline
The Gait Asymmetry Index will be calculated using temporal gait data from the affected and unaffected lower limbs. The index will quantify the degree of asymmetry between the two sides. Smartphone-derived asymmetry values will be compared with values obtained from the simultaneous Kinovea video analysis. Higher values indicate greater gait asymmetry.
Baseline

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 7월 1일

기본 완료 (추정된)

2026년 11월 1일

연구 완료 (추정된)

2026년 12월 1일

연구 등록 날짜

최초 제출

2026년 7월 16일

QC 기준을 충족하는 최초 제출

2026년 7월 24일

처음 게시됨 (실제)

2026년 7월 28일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 7월 28일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 7월 24일

마지막으로 확인됨

2026년 7월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다