이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Measuring Normal Esophageal Flexibility in Children Using EndoFLIP (EndoFLIP)

2026년 9월 2일 업데이트: Brett J. Hoskins, Indiana University

Prospective Measurement of Normative Esophageal Distensibility Using EndoFLIP in Asymptomatic Children

This study will measure normal esophageal flexibility (distensibility) in children using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP). Children who are already undergoing anesthesia for clinically indicated colonoscopy with colonic motility catheter placement and who have no history or symptoms of esophageal disease will undergo a brief EndoFLIP measurement lasting approximately 3-5 minutes before their scheduled procedure. The information collected will help establish preliminary normal pediatric reference values for esophageal distensibility, which may improve the evaluation of children with esophageal disorders in the future.

연구 개요

상세 설명

The Endoluminal Functional Lumen Imaging Probe (EndoFLIP) is an FDA-cleared device that measures the size, pressure, and flexibility (distensibility) of the esophagus. In adults, EndoFLIP measurements are routinely used to evaluate esophageal motility disorders such as achalasia. However, normal reference values for children have not been established, and pediatric interpretation currently relies largely on adult data.

The purpose of this prospective, single-center observational study is to generate preliminary normative pediatric EndoFLIP measurements. One hundred children between 5 and younger than 18 years of age who are undergoing clinically indicated colonoscopy with colonic motility catheter placement under general anesthesia will be enrolled. Eligible participants must have no history of esophageal disease or surgery and no symptoms suggestive of upper gastrointestinal disease.

Immediately before the scheduled colonoscopy and motility catheter placement, an EndoFLIP catheter will be inserted through the mouth and positioned across the lower esophageal sphincter. Measurements of esophageal diameter, cross-sectional area, pressure, compliance, and distensibility index will be obtained at standardized balloon fill volumes (20-60 mL). The EndoFLIP assessment requires approximately 3-5 minutes and does not require an upper endoscopy or any additional anesthesia. After the measurements are completed, the catheter is removed and the planned clinical procedure proceeds as scheduled. No additional study visits or follow-up are required.

The primary objective is to establish preliminary normative pediatric values for esophageal distensibility and related biomechanical parameters. Secondary analyses will evaluate associations between EndoFLIP measurements and participant age, height, weight, and body mass index. These data are intended to improve interpretation of pediatric EndoFLIP studies and support future research and clinical care for children with esophageal disorders.

연구 유형

중재적

등록 (추정된)

100

단계

  • 해당 없음

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 어린이

건강한 자원 봉사자를 받아들입니다

예

연구 인구

Children 5 to younger than 18 years of age undergoing clinically indicated colonoscopy with colonic motility catheter placement at Riley Hospital for Children who have no history or symptoms of esophageal disease and are eligible to undergo a brief EndoFLIP assessment during the same anesthetic.

설명

Inclusion Criteria:

  • Age 5 to <18 years
  • Scheduled to undergo clinically indicated colonoscopy with colonic motility catheter placement under general anesthesia
  • No upper gastrointestinal symptoms (including dysphagia, recurrent vomiting, gastroesophageal reflux, or odynophagia)
  • No history of esophageal disease or esophageal surgery
  • Parent/guardian consent and participant assent, when applicable

Exclusion Criteria:

  • Known or suspected esophageal pathology
  • Prior esophageal surgery or instrumentation
  • Anatomic upper gastrointestinal abnormalities
  • Contraindication to anesthesia or EndoFLIP catheter placement

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 다른
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
다른: Asymptomatic Children Undergoing EndoFLIP Assessment
Children 5 to younger than 18 years of age undergoing clinically indicated colonoscopy with colonic motility catheter placement under general anesthesia who have no history or symptoms of esophageal disease. Participants undergo a single 3-5 minute EndoFLIP assessment before the scheduled procedure to measure esophageal distensibility index, diameter, cross-sectional area, compliance, and pressure for development of preliminary normative pediatric reference values.
The Endoluminal Functional Lumen Imaging Probe (EndoFLIP) is an FDA-cleared impedance planimetry device used to measure esophageal diameter, cross-sectional area, intraballoon pressure, distensibility index, and compliance. In this study, the EndoFLIP catheter is inserted orally during general anesthesia immediately before clinically indicated colonoscopy with colonic motility catheter placement. Measurements are obtained over approximately 3-5 minutes at standardized balloon fill volumes of 20-60 mL, after which the catheter is removed and the planned clinical procedure proceeds. The EndoFLIP assessment is performed solely for research purposes to establish preliminary normative pediatric esophageal biomechanical reference values.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Esophageal Distensibility
기간: During the procedure (approximately 3-5 minutes)
Esophageal distensibility index measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.
During the procedure (approximately 3-5 minutes)
Esophageal Diameter
기간: During the procedure (approximately 3-5 minutes)
Esophageal diameter measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.
During the procedure (approximately 3-5 minutes)
Esophageal Cross-sectional Area
기간: During the procedure (approximately 3-5 minutes)
Esophageal cross-sectional area measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.
During the procedure (approximately 3-5 minutes)
Esophageal Compliance
기간: During the procedure (approximately 3-5 minutes)
Esophageal compliance measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.
During the procedure (approximately 3-5 minutes)
Intraballoon Pressure
기간: During the procedure (approximately 3-5 minutes)
Intraballoon pressure measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.
During the procedure (approximately 3-5 minutes)

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

협력자

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 10월 1일

기본 완료 (추정된)

2028년 9월 30일

연구 완료 (추정된)

2028년 9월 30일

연구 등록 날짜

최초 제출

2026년 7월 31일

QC 기준을 충족하는 최초 제출

2026년 8월 4일

처음 게시됨 (실제)

2026년 8월 10일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 8일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 2일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 28226

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

예

미국에서 제조되어 미국에서 수출되는 제품

예

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다