- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07819149
Assessment of Posterior Subluxation of the Humeral Head Using Biplanar Imaging in the Upright Position in Patients Scheduled for Total Shoulder Arthroplasty (SubPostEOS)
Total shoulder replacement is now recognized as a reliable and effective therapeutic option for the treatment of various degenerative joint conditions. Over time, clinical outcomes have significantly improved, both in terms of patient satisfaction and pain relief and functional recovery. Anatomical total shoulder replacement (TSR) has become the gold standard for pathologies such as glenohumeral osteoarthritis with an intact rotator cuff, with an estimated incidence of 12.5 cases per 100,000 patients, while reverse total shoulder replacement, intended primarily for pathologies of massive, irreparable rotator cuff tears, has an estimated incidence of 19.3 cases per 100,000 patients. These surgical approaches restore shoulder mobility, particularly during elevation movements, while significantly reducing pain.
However, loosening of the glenoid implant remains one of the main complications observed after total shoulder arthroplasty (TSA), often associated with increased pain, impaired function, and decreased overall patient satisfaction. Analysis of the explanted glenoid components frequently reveals posterior wear of the glenoid, which is closely correlated with the phenomenon of loosening. Among the factors likely to contribute to this complication, the rate of preoperative posterior subluxation of the humeral head has been identified as a major determinant of clinical outcomes in acetabular impingement (AIM), due to the progressive postoperative recurrence of this subluxation and its deleterious mechanical effects on the glenoid. Furthermore, the rate of posterior subluxation of the humeral head wa historically calculated from 2D CT scans obtained preoperatively. More recently, the limitations of the 2D approach have been highlighted, thus giving way to quantification using 3D reconstructions from the preoperative CT scan. However, whether for the 2D or 3D approach, the CT scan is performed while the patient is lying on their back. Although they did not directly quantify the posterior subluxation of the humeral head, showed, in healthy individuals, that the kinematics of the shoulder (i.e., glenohumeral angle) and more specifically the translation of the humeral head relative to the glenoid were different depending on whether the participant was lying down or standing. Considering that the majority of daily human activities are performed with the torso upright, it is crucial to determine whether the estimated rate of posterior subluxation of the humeral head and shoulder kinematics (i.e., glenohumeral angles) measured in the supine position accurately reflects the actual measurements when the patient is standing. One reason for this discrepancy could be the difficulty in measuring the rate of posterior subluxation of the humeral head and shoulder kinematics in the upright position. Standard motion analysis methods using video systems are not precise enough to measure these parameters, particularly due to soft tissue artifacts. Conversely, biplanar fluoroscopy or low-dose imaging (EOS®) are the gold standard for measuring shoulder kinematics with accuracy on the order of degrees and millimeters. However, no study to date has quantified the rate of posterior humeral head subluxation and shoulder kinematics in patients in an upright position.
The main objective of this study is to evaluate the influence of position, namely supine versus upright, on the quantification of posterior subluxation of the humeral head in patients scheduled for total shoulder replacement.
연구 개요
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Marie-Hélène Barba
연구 연락처 백업
- 이름: Jean-François Oudet, M.
- 전화번호: 0033683346567
- 이메일: jf.oudet@ecten.eu
연구 장소
-
-
-
Lyon, 프랑스, 69008
- Hôpital privé Jean Mermoz
-
연락하다:
- Lionel Neyton, Dr
- 전화번호: 0033 0437530057
- 이메일: neyton.lionel@orange.fr
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Major
- Scheduled for shoulder arthroplasty
- Having undergone a CT scan of the shoulder scheduled for arthroplasty prior to the operation
- Patient having signed an informed consent form
- Patient affiliated with a social security scheme or beneficiary of such a scheme, according to Article L.1124-1 of the Public Health Code
Exclusion Criteria:
- Contraindications from surgeons
- Contraindication to EOS® examination
- Anthropometry incompatible with EOS® examination
- Scheduled for shoulder arthroplasty due to : fracture, sequelae of a fracture, history of glenoid graft
- History of fracture of the humerus, scapula, or clavicle
- Vulnerable and/or protected individual: adult under guardianship, curatorship, or other legal protection, deprived of liberty by judicial or administrative decision
- Pregnant, breastfeeding, or postpartum woman
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 다른
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Shoulder arthroplasty
|
It involves taking a biplanar radiographic image (2 x-rays) of the operated side. Patients stand in the booth with their arms at their sides. Before the EOS scan, a preview image will be taken to verify the correct patient positioning. |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Percentage of posterior subluxation of the humeral head measured in supine and upright positions
기간: one day
|
between 0 and 100
|
one day
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- 2026-A00569-42
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .