Effect of Systematic and Sequential Leg Elevation on Cardiac Output in Healthy Volunteers (SYSLE-1)
Effect of Systematic and Sequential Leg Elevation on Cardiac Output in Healthy Volunteers: A Single-Center Prospective Crossover Physiological Study
Passive leg raising (PLR) transiently increases venous return and cardiac preload and is commonly used to predict fluid responsiveness in critically ill patients. Repeated fluid boluses contribute to fluid overload in septic shock, whereas PLR may provide similar hemodynamic effects without fluid administration.
Before evaluating repeated PLR in septic shock patients, it is necessary to determine whether the cardiac output response to PLR remains present during repeated PLR maneuvers.
SYSLE-1 is a prospective interventional physiological crossover study conducted in healthy volunteers. Participants will undergo six consecutive passive leg raising sessions performed either during spontaneous breathing or non-invasive ventilation, in randomized order. The study aims to determine whether the increase in cardiac output induced by the first PLR maneuver persists during repeated PLR sessions.
연구 개요
상태
정황
상세 설명
The passive leg raising maneuver induces a reversible transfer of venous blood from the lower extremities toward the thoracic compartment, thereby increasing cardiac preload. In preload-dependent individuals, PLR increases stroke volume and cardiac output without administration of intravenous fluids.
In septic shock, repeated fluid challenges remain common during the first days of management but may contribute to positive fluid balance, tissue edema, organ dysfunction, and increased mortality. Since the hemodynamic effects of PLR resemble those of a fluid challenge while avoiding fluid administration, repeated PLR maneuvers could represent an alternative strategy for improving preload and cardiac output.
The SYSLE-1 study is designed as the first phase of a broader research program aimed at evaluating repeated PLR in septic shock patients. The present study investigates whether the cardiac output response to PLR remains preserved during six repeated PLR sessions in healthy volunteers.
Participants will complete two study days in randomized order: one under spontaneous breathing and one under non-invasive ventilation. During each study day, six PLR sessions lasting 10 minutes each will be performed and separated by 50-minute recovery periods in a semi-recumbent position.
Cardiac output measured by thoracic bioreactance is the primary endpoint. Additional physiological measurements include arterial pressure, heart rate variability, brachial artery diameter, cardiac output measured using pulse contour analysis and echocardiography, end-tidal carbon dioxide, comfort assessments, and safety outcomes.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Fanny LOUAT
- 전화번호: +33 0238744295
- 이메일: fanny.louat@chu-orleans.fr
연구 연락처 백업
- 이름: Mai-Anh PhD NAY, Physician
- 전화번호: +33 02.38.22.95.57
- 이메일: mai-anh.nay@chu-orleans.fr
연구 장소
-
-
Loiret
-
Orléans, Loiret, 프랑스, 45067
- Centre Hospitalier Régional d'Orléans
-
연락하다:
- Mai-Anh PhD NAY, Physician
- 전화번호: +33 02.38.22.95.57
- 이메일: mai-anh.nay@chu-orleans.fr
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Male or female participant.
- Age 18 years or older.
- Healthy volunteer without known acute or chronic disease.
- No significant cardiovascular or respiratory disease.
- No medication use within 10 days before the first study day (except oral contraceptives).
- Intact upper and lower limbs.
- Written informed consent.
Exclusion Criteria:
- Body mass index greater than 35 kg/m².
- Use of illicit psychoactive substances within the previous 3 months.
- Congenital or acquired absence of part or all of an upper or lower limb.
- Known allergy to hydrocolloid dressings.
- Pregnant or breastfeeding women.
- Under guardianship, curatorship, or legal protection.
- Deprived of liberty.
- Not affiliated with a health insurance system.
- Participation in another drug study during an exclusion period.
- Member of the Lieu de Recherches Interventionnelles sur la Personne Humaine (LRIPH) or Intensive Care Unit staff.
- Refusal to participate.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 기초 과학
- 할당: 무작위
- 중재 모델: 크로스오버 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Spontaneous Breathing
Participants undergo one study day during spontaneous breathing in room air. Each study day consists of six repeated passive leg raising (PLR) sessions performed once every hour over approximately six hours. Before each PLR session, participants remain in a semi-recumbent position (30° trunk elevation) for 5 minutes. They are then moved to a passive leg raising position with the trunk horizontal and legs elevated to 45° for 10 minutes using an electrically operated bed. Following each PLR maneuver, participants return to the semi-recumbent position for 50 minutes before the next PLR session. Throughout the study day, continuous or repeated measurements of cardiac output, arterial pressure, heart rate, respiratory rate, oxygen saturation, heart rate variability, echocardiographic parameters, and brachial artery diameter are performed according to the study schedule. |
Passive leg raising is performed using an electrically operated hospital bed to move participants from a semi-recumbent position (30° trunk elevation) to a position with the trunk horizontal and legs elevated at 45°. Each maneuver lasts 10 minutes and is repeated six times at hourly intervals. Non-invasive ventilation is delivered via an oronasal mask using a critical care ventilator. NIV is applied for 5 minutes before passive leg raising, throughout the 10-minute maneuver, and for 5 minutes after return to the semi-recumbent position, resulting in six repeated 20-minute NIV periods during the study day. Ventilator settings: FiO2 21%, initial PEEP 5 cmH2O (adjustable down to 2 cmH2O for tolerance), and pressure support 0-5 cmH2O, titrated to avoid a tidal volume >15 mL/kg predicted body weight (target 8-12 mL/kg). |
|
실험적: Non-Invasive Ventilation
Participants undergo one study day during non-invasive ventilation (NIV) delivered through an oronasal mask. Each study day consists of 6 repeated passive leg raising (PLR) sessions performed once every hour over approximately 6 hours. Before each PLR session, NIV is applied for 5 minutes while the participant remains in a semi-recumbent position (30° trunk elevation). Participants are then moved to a passive leg raising position with the trunk horizontal and legs elevated to 45° for 10 minutes while NIV is maintained. NIV is continued for an additional 5 minutes after return to the semi-recumbent position and is reapplied during the last 5 minutes preceding the next PLR session. This results in repeated 20-minute NIV exposure periods surrounding each PLR maneuver. Continuous or repeated measurements of cardiac output, arterial pressure, heart rate, respiratory rate, oxygen saturation, end-tidal carbon dioxide, heart (etc.) are performed according to the study schedule. |
Passive leg raising is performed using an electrically operated hospital bed to move participants from a semi-recumbent position (30° trunk elevation) to a position with the trunk horizontal and legs elevated at 45°. Each maneuver lasts 10 minutes and is repeated six times at hourly intervals. Non-invasive ventilation is delivered via an oronasal mask using a critical care ventilator. NIV is applied for 5 minutes before passive leg raising, throughout the 10-minute maneuver, and for 5 minutes after return to the semi-recumbent position, resulting in six repeated 20-minute NIV periods during the study day. Ventilator settings: FiO2 21%, initial PEEP 5 cmH2O (adjustable down to 2 cmH2O for tolerance), and pressure support 0-5 cmH2O, titrated to avoid a tidal volume >15 mL/kg predicted body weight (target 8-12 mL/kg). |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Change in cardiac output during the sixth passive leg raising session compared with the first passive leg raising session, for each day of study procedure
기간: During study procedures on Days 1 and 2 (up to 10 days apart). From enrollment to the end of study (day 2) at 3 months maximum.
|
Cardiac output measured every minute using thoracic bioreactance. The study will assess whether the increase in cardiac output during the sixth PLR session is non-inferior to 30% of the increase observed during the first PLR session. |
During study procedures on Days 1 and 2 (up to 10 days apart). From enrollment to the end of study (day 2) at 3 months maximum.
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Change in cardiac output response across PLR sessions 1 to 6.
기간: During each study day, across six passive leg raising sessions performed over approximately 6 hours. From enrollment to the end of study (day 2) at 3 months maximum.
|
Change in cardiac output measured by thoracic bioreactance during each passive leg raising session. Cardiac output changes observed during sessions 1 through 6 will be described and compared. |
During each study day, across six passive leg raising sessions performed over approximately 6 hours. From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Effect of ventilation mode on cardiac output response to passive leg raising
기간: During the two study days (up to 10 days apart). From enrollment to the end of study (day 2) at 3 months maximum.
|
Comparison of the increase in cardiac output induced by passive leg raising between spontaneous breathing sessions and non-invasive ventilation sessions using thoracic bioreactance measurements. |
During the two study days (up to 10 days apart). From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Cardiac output evolution during passive leg raising
기간: During each 10-minute passive leg raising session. From enrollment to the end of study (day 2) at 3 months maximum
|
Minute-by-minute cardiac output measured by thoracic bioreactance during passive leg raising to characterize the temporal profile of the hemodynamic response. |
During each 10-minute passive leg raising session. From enrollment to the end of study (day 2) at 3 months maximum
|
|
Effect of ventilation mode on cardiac output evolution during passive leg raising
기간: During each 10-minute passive leg raising session on both study days. From enrollment to the end of study (day 2) at 3 months maximum.
|
Comparison of cardiac output trajectories measured during passive leg raising under spontaneous breathing and non-invasive ventilation. |
During each 10-minute passive leg raising session on both study days. From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Cardiac output recovery after passive leg raising
기간: During the 50-minute recovery period following each passive leg raising session. From enrollment to the end of study (day 2) at 3 months maximum.
|
Evolution of cardiac output after returning from passive leg raising to the semi-recumbent position, assessed using thoracic bioreactance. |
During the 50-minute recovery period following each passive leg raising session. From enrollment to the end of study (day 2) at 3 months maximum.
|
|
LF/HF ratio derived from heart rate variability.
기간: During each study day, across six passive leg raising sessions (approximately 6 hours). From enrollment to the end of study (day 2) at 3 months maximum.
|
Changes in the low-frequency to high-frequency (LF/HF) ratio derived from heart rate variability analysis as an indicator of autonomic nervous system activity during repeated passive leg raising sessions |
During each study day, across six passive leg raising sessions (approximately 6 hours). From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Change in brachial artery diameter measured by ultrasound.
기간: Measured before, during, and near the end of each passive leg raising session during both study days. From enrollment to the end of study (day 2) at 3 months maximum.
|
Brachial artery diameter assessed by ultrasound to characterize vasomotor responses associated with passive leg raising. |
Measured before, during, and near the end of each passive leg raising session during both study days. From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Agreement between cardiac output measurement methods (bioreactance, Clearsight®, echocardiography).
기간: During each study day, across all passive leg raising sessions. From enrollment to the end of study (day 2) at 3 months maximum.
|
Comparison of cardiac output measurements obtained by thoracic bioreactance, pulse contour analysis (Clearsight®), and transthoracic echocardiography. |
During each study day, across all passive leg raising sessions. From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Agreement between blood pressure measurement methods (oscillometry and Clearsight®).
기간: During each study day, across all passive leg raising sessions. From enrollment to the end of study (day 2) at 3 months maximum.
|
Comparison of systolic, diastolic, and mean arterial pressure measurements obtained by automated oscillometry and the Clearsight® system |
During each study day, across all passive leg raising sessions. From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Correlation between end-tidal carbon dioxide and cardiac output during non-invasive ventilation
기간: During the non-invasive ventilation study day (approximately 6 hours). From enrollment to the end of study (day 2) at 3 months maximum.
|
Correlation between minute-by-minute end-tidal carbon dioxide values and cardiac output measured by thoracic bioreactance during passive leg raising sessions performed under non-invasive ventilation |
During the non-invasive ventilation study day (approximately 6 hours). From enrollment to the end of study (day 2) at 3 months maximum.
|
|
Participant-reported discomfort,.
기간: Assessed during and after each passive leg raising session on both study days (approximately 6 hours / study day). From enrollment to the end of study (day 2) at 3 months maximum. Scale from 0 to 10: 0 no discomfort and 10 worst imaginable discomfort.
|
Participant ratings of discomfort using an 11-point numerical rating scale during study procedures and non-invasive ventilation exposure. |
Assessed during and after each passive leg raising session on both study days (approximately 6 hours / study day). From enrollment to the end of study (day 2) at 3 months maximum. Scale from 0 to 10: 0 no discomfort and 10 worst imaginable discomfort.
|
|
Participant-reported respiratory difficulty.
기간: Assessed during and after each passive leg raising session on both study days (approximately 6 hours per study day). From enrollment to the end of study (day 2) at 3 months maximum. Scale from 0 to 10: 0 no difficulty and 10 worst imaginable difficulty.
|
Participant ratings of breathing difficulty using an 11-point numerical rating scale during study procedures and non-invasive ventilation exposure. |
Assessed during and after each passive leg raising session on both study days (approximately 6 hours per study day). From enrollment to the end of study (day 2) at 3 months maximum. Scale from 0 to 10: 0 no difficulty and 10 worst imaginable difficulty.
|
|
Participant-reported pain.
기간: Assessed during and after each passive leg raising session on both study days (approximately 6 hours per study day). From enrollment to the end of study (day 2) at 3 months maximum. Scale from 0 to 10: 0 no pain and 10 worst imaginable pain.
|
Participant ratings of pain using an 11-point numerical rating scale during study procedures and non-invasive ventilation exposure. |
Assessed during and after each passive leg raising session on both study days (approximately 6 hours per study day). From enrollment to the end of study (day 2) at 3 months maximum. Scale from 0 to 10: 0 no pain and 10 worst imaginable pain.
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Mai-Anh PhD NAY, Physician, Centre Hospitalier Régional d'Orléans
간행물 및 유용한 링크
일반 간행물
- Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med. 2011 Feb;39(2):259-65. doi: 10.1097/CCM.0b013e3181feeb15.
- Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G. Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest. 2002 Apr;121(4):1245-52. doi: 10.1378/chest.121.4.1245.
- Boulain T, Boisrame-Helms J, Ehrmann S, Lascarrou JB, Bougle A, Chiche A, Lakhal K, Gaudry S, Perbet S, Desachy A, Cabasson S, Geneau I, Courouble P, Clavieras N, Massanet PL, Bellec F, Falquet Y, Reminiac F, Vignon P, Dequin PF, Meziani F. Volume expansion in the first 4 days of shock: a prospective multicentre study in 19 French intensive care units. Intensive Care Med. 2015 Feb;41(2):248-56. doi: 10.1007/s00134-014-3576-1. Epub 2014 Dec 2.
- Aya HD, Ster IC, Fletcher N, Grounds RM, Rhodes A, Cecconi M. Pharmacodynamic Analysis of a Fluid Challenge. Crit Care Med. 2016 May;44(5):880-91. doi: 10.1097/CCM.0000000000001517.
- Angus DC, van der Poll T. Severe sepsis and septic shock. N Engl J Med. 2013 Aug 29;369(9):840-51. doi: 10.1056/NEJMra1208623. No abstract available.
- Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010 Sep;36(9):1475-83. doi: 10.1007/s00134-010-1929-y. Epub 2010 May 26.
- Carrara M, Ferrario M, Bollen Pinto B, Herpain A. The autonomic nervous system in septic shock and its role as a future therapeutic target: a narrative review. Ann Intensive Care. 2021 May 17;11(1):80. doi: 10.1186/s13613-021-00869-7.
- Amekran Y, Damoun N, El Hangouche AJ. A focus on the assessment of the autonomic function using heart rate variability. Glob Cardiol Sci Pract. 2025 Feb 28;2025(1):e202512. doi: 10.21542/gcsp.2025.12. eCollection 2025 Feb 28.
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- CHUO-2025-20
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .