- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07866573
UltraTrac for Cardiac Output Monitoring in Congenital Heart Disease (UltraTrac)
UltraTrac for Noninvasive Cardiac Output Monitoring in Patients With Congenital Heart Disease: A Multi-Setting Pilot Feasibility Study
This pilot feasibility study will evaluate UltraTrac, an investigational noninvasive wearable device for continuous cardiac output monitoring, in patients with congenital heart disease.
UltraTrac integrates impedance cardiography and carotid Doppler ultrasound to estimate cardiac output. Participants undergoing clinically indicated cardiac catheterization, cardiac MRI, or cardiac intensive care unit monitoring will have UltraTrac measurements collected during routine clinical care.
UltraTrac measurements will be compared with reference standard or clinical hemodynamic measurements, including thermodilution, direct Fick method, cardiac magnetic resonance imaging-derived cardiac output, and clinical hemodynamic assessments before and after vasoactive medication changes. UltraTrac data will not be used to guide clinical decision-making.
연구 개요
상세 설명
Accurate continuous hemodynamic monitoring is important in the management of pediatric and neonatal patients with congenital heart disease, but current monitoring methods may be invasive, intermittent, operator-dependent, or difficult to apply in small pediatric patients.
UltraTrac is an investigational wearable hemodynamic monitoring device that integrates impedance cardiography and carotid Doppler ultrasound into a single noninvasive platform. The device uses surface electrodes on the thorax and a wearable Doppler probe positioned over the carotid artery. No vascular access, ionizing radiation, or invasive procedure is required for device application or operation.
This prospective, single-center, pilot feasibility study will evaluate the accuracy and feasibility of UltraTrac for noninvasive cardiac output monitoring in patients with congenital heart disease across three clinical settings: the cardiac catheterization laboratory, the cardiac MRI suite, and the cardiac intensive care unit.
In the cardiac catheterization laboratory arm, UltraTrac cardiac output measurements will be compared with thermodilution and/or direct Fick cardiac output measurements obtained during clinically indicated cardiac catheterization. In the cardiac MRI arm, UltraTrac measurements will be compared with cardiac MRI-derived cardiac output measurements obtained as part of clinically indicated imaging. In the cardiac intensive care unit arm, UltraTrac will be used to assess directional changes in cardiac output before and after clinically indicated introduction or titration of vasoactive medications.
UltraTrac measurements will not be used to guide clinical care. All clinical decisions will remain the responsibility of the treating clinical team, and UltraTrac data will be analyzed offline after data collection.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Brittany Faanes
- 전화번호: 612-625-5929
- 이메일: grego318@umn.edu
연구 장소
-
-
Minnesota
-
Minneapolis, Minnesota, 미국, 55454
- M Health Fairview University of Minnesota Masonic Children's Hospital
-
연락하다:
- Juan Carlos Samayoa
- 이메일: samay008@umn.edu
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- 0-80 years old
- Participant weight of at least 2 kg
- Diagnosis of congenital heart disease of any anatomic type, including but not limited to repaired or unrepaired single ventricle physiology, biventricular congenital heart disease, valvular disease, septal defects, and conotruncal anomalies
- Clinically indicated cardiac catheterization, cardiac MRI, or cardiac intensive care unit admission during the study enrollment period
- For Arm 1: scheduled to undergo hemodynamic cardiac catheterization during which thermodilution and/or direct Fick cardiac output measurements will be performed as part of standard clinical care
- For Arm 2: scheduled to undergo cardiac MRI during which CMR-derived cardiac output measurement will be obtained as part of the clinical protocol
- For Arm 3: admitted to the cardiac intensive care unit and anticipated to require initiation or titration of vasoactive medication as part of standard clinical management
- Parental permission, and assent when applicable, obtained from at least one parent or legally authorized representative
Exclusion Criteria:
- Known allergy or prior skin reaction to adhesive electrodes or ultrasound gel
- Skin breakdown, wound, or infection at any proposed electrode or probe placement site that would preclude safe device application
- Hemodynamic instability at the time of enrollment that, in the judgment of the treating clinician, would preclude safe participation in research procedures
- Known carotid artery abnormality, prior carotid surgery, or anatomic variant that would preclude reliable carotid Doppler signal acquisition
- Participant or family refusal to participate or inability to obtain informed consent or parental permission
- Pregnant women/persons
- Fetuses
- Prisoners
- Adults lacking capacity to consent or adults with diminished or fluctuating capacity to consent
- Employees of the researcher
- Students of the researcher
- Active members of the military or DoD personnel
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 특수 증상
- 할당: 무작위화되지 않음
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Cardiac Catheterization Laboratory UltraTrac Monitoring
Participants undergoing clinically indicated cardiac catheterization will have UltraTrac measurements obtained and compared with thermodilution and/or direct Fick cardiac output measurements obtained as part of standard clinical care. |
UltraTrac is an investigational wearable hemodynamic monitoring device that integrates impedance cardiography and carotid Doppler ultrasound into a single noninvasive platform. In this study, UltraTrac will be used only as an observational monitoring device. UltraTrac measurements will not guide clinical decision-making, and all clinical management will proceed according to standard of care.
다른 이름들:
|
|
실험적: Cardiac MRI UltraTrac Monitoring
Participants undergoing clinically indicated cardiac MRI will have UltraTrac measurements obtained near the time of cardiac MRI and compared with CMR-derived cardiac output measurements obtained as part of standard clinical care. |
UltraTrac is an investigational wearable hemodynamic monitoring device that integrates impedance cardiography and carotid Doppler ultrasound into a single noninvasive platform. In this study, UltraTrac will be used only as an observational monitoring device. UltraTrac measurements will not guide clinical decision-making, and all clinical management will proceed according to standard of care.
다른 이름들:
|
|
실험적: Cardiac Intensive Care Unit UltraTrac Monitoring
Participants admitted to the cardiac intensive care unit will have UltraTrac measurements obtained before and after clinically indicated introduction or titration of vasoactive medications. UltraTrac trending will be compared with concurrent clinical hemodynamic assessments. |
UltraTrac is an investigational wearable hemodynamic monitoring device that integrates impedance cardiography and carotid Doppler ultrasound into a single noninvasive platform. In this study, UltraTrac will be used only as an observational monitoring device. UltraTrac measurements will not guide clinical decision-making, and all clinical management will proceed according to standard of care.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Agreement Between UltraTrac-Derived Cardiac Output and Reference Standard Cardiac Output During Cardiac Catheterization
기간: Periprocedural cardiac catheterization
|
Agreement between cardiac output measurements obtained periprocedural by UltraTrac and cardiac output measurements obtained by thermodilution and/or direct Fick method during clinically indicated cardiac catheterization will be assessed using Bland-Altman analysis. Percentage error will be calculated as two standard deviations of the bias divided by the mean cardiac output of the two methods. A percentage error of 30% or less will be considered clinically acceptable agreement. |
Periprocedural cardiac catheterization
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Agreement Between UltraTrac-Derived Cardiac Output and CMR-Derived Cardiac Output
기간: Periprocedural cardiac MRI encounter
|
Periprocedural agreement between UltraTrac-derived and CMR-derived cardiac output (L/min) and cardiac index (L/min/m²) will be assessed using Bland-Altman analysis. CMR-derived cardiac output will be obtained during clinically indicated cardiac MRI using phase contrast flow measurement and volumetric assessment. Each participant will contribute one measurement pair per encounter, consisting of one CMR-derived cardiac output value and the temporally closest UltraTrac-derived measurement. Reported parameters will include mean bias, limits of agreement, percentage error, and 95% confidence intervals for the bias and limits of agreement. Percentage error will be calculated as 2 standard deviations of the bias divided by the mean cardiac output of the two methods × 100. Percentage error ≤30% will indicate clinically acceptable agreement by Critchley and Critchley criteria. Results will be reported overall and by age group, weight category, and cardiac anatomy. |
Periprocedural cardiac MRI encounter
|
|
Concordance Rate Between UltraTrac-Derived Directional Cardiac Output Changes and Clinical Hemodynamic Assessment in the CICU
기간: Baseline and periprocedure up to 72 hrs post procedure.
|
The ability of UltraTrac to detect directional changes in cardiac output will be assessed during the immediate postoperative period and throughout the broader CICU admission. Measurements will be obtained during pre-defined windows before and after each clinically indicated vasoactive medication initiation or titration event. The composite clinical reference standard will include heart rate, arterial blood pressure, capillary refill time, acid-base status and lactate, and invasive hemodynamic parameters where available (arterial line, central venous pressure). Concordance between UltraTrac-derived directional cardiac output changes and composite clinical hemodynamic assessment will be reported as a concordance rate (%). The specific statistical method for concordance analysis will be determined and pre-specified prior to data collection and will be detailed in the statistical analysis plan. |
Baseline and periprocedure up to 72 hrs post procedure.
|
|
Percentage of Participants With Successful UltraTrac Device Placement and Analyzable Waveform Acquisition
기간: Baseline and periprocedural
|
Feasibility of UltraTrac device placement and signal acquisition will be assessed as the proportion of enrolled participants with successful device placement and analyzable waveform data acquisition across the cardiac catheterization laboratory, cardiac MRI suite, and cardiac intensive care unit settings. |
Baseline and periprocedural
|
|
Time Required for UltraTrac Device Application
기간: Baseline and periprocedural
|
Time required for UltraTrac device application will be recorded by study personnel during the specific clinical setting in which the device is applied. |
Baseline and periprocedural
|
|
UltraTrac Tolerability and Comfort Questionnaire Score
기간: Baseline and periprocedural
|
Comfort and tolerability of device application will be assessed using the UltraTrac Tolerability and Comfort Questionnaire, a standardized instrument developed and defined prospectively by the study team prior to data collection. The questionnaire uses a 5-point rating scale ranging from 1 (minimum, very uncomfortable or intolerable) to 5 (maximum, completely comfortable and well tolerated), where higher scores indicate a better outcome. The questionnaire will be administered to the participant, caregiver, or both at the time of device removal following each study encounter. Mean scores and standard deviations will be reported for the overall cohort and stratified by age group, clinical setting, and device application duration. |
Baseline and periprocedural
|
|
UltraTrac Waveform Signal Quality Scale Score
기간: Baseline and periprocedural
|
Signal quality will be assessed using the UltraTrac Waveform Signal Quality Scale, a standardized 5-point rating scale ranging from 1 (minimum, uninterpretable waveform) to 5 (maximum, optimal waveform quality), where higher scores indicate a better outcome. This scale was developed and defined prospectively by the study team prior to data collection. Scores will be assigned independently to ICG and carotid Doppler waveform acquisitions by two blinded reviewers. Mean scores and standard deviations will be reported for the overall cohort and across the following pre-specified subgroups: age (neonates 0-30 days, infants 31 days-12 months, children 1-12 years, adolescents and young adults 13-21 years, and adults 22 years and older), weight (<3 kg, 3-10 kg, 10-20 kg, >20 kg), and cardiac anatomy (single ventricle vs. biventricular). Inter-rater agreement will be reported using intraclass correlation coefficient. |
Baseline and periprocedural
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Juan Carlos Samayoa, University of Minnesota
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- PEDS-2026-34943
- STUDY00028830 (기타 식별자: University of Minnesota-IRB)
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .