- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07935265
Dual Energy Focal Ablation of Premature Ventricular Complexes (DUAL-PVC)
Dual Energy (RF/PF) Focal Ablation of Premature Ventricular Complexes: the DUAL-PVC Prospective Clinical Trial
The purpose of this research is to understand whether a dual-energy catheter ablation system that uses radiofrequency (RF) and pulsed-field (PF) energy can safely and effectively treat premature ventricular contractions (PVCs).
연구 개요
상태
정황
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Konstantinos Siontis, MD
- 전화번호: 507-255-0774
- 이메일: siontis.konstantinos@mayo.edu
연구 장소
-
-
Minnesota
-
Rochester, Minnesota, 미국, 55905
- Mayo Clinic
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
-
≥10% burden of the target PVC on ambulatory rhythm monitoring within 3 months prior to enrollment. The qualifying ambulatory monitor may be of any duration (1-30 days) per standard of care and may be distinct from the baseline 12-lead Holter required within 30 days before ablation
-
Guideline-supported indication for first-time or redo catheter ablation of PVCs at the judgment of the electrophysiologist. Specifically:
- Patients with symptomatic PVCs for whom antiarrhythmic medications are ineffective, not tolerated, or not the patient's preference.
- Suspected or confirmed PVC-induced cardiomyopathy
- Enrollment of patients requiring a redo procedure will be capped at 30% of planned enrollment (n=18) if the target PVC is the same or similar to that targeted in previous procedure(s), per review of the study investigator
-
Patients with and without known structural heart disease are eligible
-
Ability to undergo study-directed cardiac MRI pre- and post-procedure
-
Ability to undergo study-directed post-ablation coronary CT angiography
-
Ability to provide written informed consent
Exclusion Criteria:
- LVEF <35%
- NYHA class IV
- Presence of multifocal PVCs (>=3 distinct morphologies) on available pre-baseline standard-of-care ambulatory monitor and ECG tracings per the review of the study team.
- PVCs attributable to a reversible or non-cardiac cause (e.g., electrolyte imbalance or active thyroid disease).
- History of sustained VT or VF.
- Current or recent (<4 weeks) decompensated heart failure.
- Active systemic infection.
- Contraindication to LGE-MRI or contrast CT.
- Known allergy to iodinated contrast dye that cannot be adequately managed with pre-medication protocol.
- Thrombocytopenia (platelet count <50,000/mm³) or known coagulopathy.
- Contraindication to systemic anticoagulation.
- Severe valvular disease requiring future intervention.
- Mechanical valve prosthesis.
- Pregnancy.
- Recent acute coronary syndrome (<6 months).
- Un-revascularized coronary artery disease.
- Presence of left ventricular assist device (LVAD) or transplanted heart.
- Presence of intracardiac thrombus.
- Current use of inotropes.
- Recent stroke or TIA (<6 months).
- Presence of a systemic illness likely to limit survival to <1 year.
- Patient enrollment in other clinical study that could conflict with the current investigation.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: RF-PF Sequential Ablation
Participants are assigned to receive radiofrequency (RF) followed by pulsed-field (PF) at each selected treatment site. For each PF treatment, 24 PF bursts are delivered. Up to three stacked lesions may be performed at the same location. |
The THERMOCOOL SMARTTOUCH™ SF Bi-Directional Navigation Catheter is an irrigated, contact-force-sensing catheter used to map the heart and deliver radiofrequency (RF) or pulsed-field (PF) energy to selected treatment sites. The catheter is connected to the TRUPULSE™ Generator, which provides both energy types, and to the nGEN™ Pump, which controls saline irrigation. The system is used with the CARTO™ 3 electroanatomic mapping system and workstation with the VISITAG SURPOINT™ Module to display heart anatomy, catheter location, catheter-to-tissue contact, and treatment information during the procedure. |
|
실험적: PF-Only Ablation
Participants are assigned to receive pulsed-field (PF) alone at each selected treatment site. For each PF treatment, 24 PF bursts are delivered. Up to three stacked lesions may be performed at the same location. |
The THERMOCOOL SMARTTOUCH™ SF Bi-Directional Navigation Catheter is an irrigated, contact-force-sensing catheter used to map the heart and deliver radiofrequency (RF) or pulsed-field (PF) energy to selected treatment sites. The catheter is connected to the TRUPULSE™ Generator, which provides both energy types, and to the nGEN™ Pump, which controls saline irrigation. The system is used with the CARTO™ 3 electroanatomic mapping system and workstation with the VISITAG SURPOINT™ Module to display heart anatomy, catheter location, catheter-to-tissue contact, and treatment information during the procedure. |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Number of Participants With Successful Delivery of Ablation Lesions Using the Dual-Energy THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator
기간: During the index ablation procedure
|
Feasibility is defined as successful delivery of ablation energy at the targeted premature ventricular complex (PVC) site. Delivery counts as successful only if there is no study device deficiency or malfunction that prevents energy delivery, and no need to convert to a bailout ablation approach. |
During the index ablation procedure
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Acute procedural success
기간: End of the ablation procedure
|
Number of participants with elimination of the target premature ventricular contraction by the end of the procedure. |
End of the ablation procedure
|
|
Participants with greater than 80% reduction in target PVC burden
기간: 1 month, 6 months
|
Number of participants with greater than 80% reduction from baseline in the burden of the target premature ventricular contraction on Holter monitoring. |
1 month, 6 months
|
|
Change in Short Form Health Survey (SF-36) score
기간: Baseline, 1 month, 6 months
|
The 36-Item Short Form Health Survey (SF-36) is a participant-reported questionnaire that assesses health-related quality of life across eight domains: physical functioning, role limitations due to physical health, bodily pain, general health, vitality, social functioning, role limitations due to emotional problems, and mental health. Total scores range from 0 to 100. Higher scores indicate better health status. |
Baseline, 1 month, 6 months
|
|
Change in EQ-5D score
기간: Baseline, 1 month, 6 months
|
The EQ-5D is a participant-reported measure of health-related quality of life covering five dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. Responses across the five dimensions define the participant's health state. Higher scores indicate better health. |
Baseline, 1 month, 6 months
|
|
Number of Participants With New Coronary Artery Stenosis on Coronary CT Angiography at 6 Months After Ablation
기간: 6 months
|
Total number of patients with new-onset coronary luminal stenosis found on CT coronary angiography |
6 months
|
|
Total Procedure Time
기간: From start to finish of index ablation procedure
|
Total procedure time will be reported in minutes |
From start to finish of index ablation procedure
|
|
Electrogram endpoints
기간: Intraprocedure
|
EGM amplitude changes after PF, RF, and RF-PF lesion delivery |
Intraprocedure
|
|
Ablation Lesion Depth
기간: 1 month and 6 months after ablation
|
Maximum depth of the ablation lesion at the target premature ventricular complex (PVC) site. Depth is measured from the endocardial surface on late gadolinium enhancement (LGE) cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in millimeters. |
1 month and 6 months after ablation
|
|
Ablation Lesion Width
기간: 1 month and 6 months after ablation
|
Maximum width of the ablation lesion at the target PVC site, measured on LGE cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in millimeters. |
1 month and 6 months after ablation
|
|
Ablation Lesion Volume
기간: 1 month and 6 months after ablation
|
Total volume of the ablation lesion at the target PVC site, measured on LGE cardiac MRI. Only participants with an evaluable post-ablation MRI are analyzed. Reported in cubic centimeters. |
1 month and 6 months after ablation
|
|
Number of Radiofrequency (RF) Lesions Delivered per Participant
기간: During the index ablation procedure
|
Total number of RF lesions delivered with the study catheter during the index procedure |
During the index ablation procedure
|
|
Number of Pulsed-Field (PF) Lesions Delivered per Participant
기간: During the index ablation procedure
|
Total number of PF lesions delivered with the study catheter during the index procedure |
During the index ablation procedure
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Konstantinos Siontis, MD, Mayo Clinic
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- 25-013930
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .