Image Guided System for Orthopaedic Surgery
Image Guided Surgical System for Orthopaedic Trauma
This project focuses on the further development and clinical testing of an image-guided surgical system. The system will help surgeons perform procedures that involve inserting a screw, guide pin, drill bit, or other straight object into bone-for example, inserting screws in a broken hip bone. These surgeries are currently done with the help of a mobile x-ray device called a C-arm, which provides the surgeon with x-ray images during the procedure.
C-arms have some disadvantages, including image distortion, radiation exposure, and the need for time-consuming adjustments of the C-arm during the surgery. The new method would deal with these shortcomings with a computer-based system that adds to the existing C-arm system. It would provide the surgeon with a real-time view of the insertion process, and could improve the accuracy and speed of certain surgical procedures.
Disadvantages associated with C-arms include image distortion, radiation exposure, and time consuming reconfiguration of the C-arm during the insertion process. The proposed system would address these shortcomings with a computer-based system that augments the existing C-arm system.
研究概览
详细说明
This Small Business Innovation Research Phase II project supports the further development and clinical testing of an image-guided surgical system that will assist the surgeon in performing procedures that involve the insertion of a screw, guide pin, drill bit, or other linear object into bone. These surgeries are currently performed with the assistance of a mobile fluoroscopic x-ray imager known as a C-arm.
Disadvantages associated with C-arms include image distortion, radiation exposure, and time-consuming reconfiguration of the C-arm (between A/P and lateral views) during the insertion process. The proposed system would address these shortcomings with a computer-based system that augments the existing C-arm system. The new system uses an optical localizer (a stereo camera device that tracks light-emitting diodes) to monitor the location and orientation of a drill guide in the surgical field. The drill guide trajectory is then graphically superimposed on the x-ray images. This provides real-time, on-screen positional feedback to the surgeon to improve the accuracy and speed with which certain procedures involving insertion of drill bits or guide pins can be performed. The research effort will focus on the development of a clinical prototype and its evaluation by several quantitative and qualitative methods.
The commercial success of such a system depends on its acceptance by surgeons, which in turn depends on the extent to which it is a tool that provides better information to the surgeons without intruding on a procedure in which they are already highly skilled. Commercial success also depends on the ability of the system to reliably save time in the operating room. We will address these issues with cadaveric studies and subsequent clinical trials.
Proposed Commercial Applications: The initial commercial application of this system is the insertion of dynamic compression hip screws in cases of hip fracture. Because this is a common fracture, any reduction in surgical time has great potential for cost savings. Other advantages include decrease in radiation exposure and the potential reduction of serious complications. Minor modifications that allow the system to assist with numerous other orthopaedic trauma procedures are already planned.
研究类型
注册
阶段
- 阶段2
联系人和位置
学习地点
-
-
Illinois
-
Park Ridge、Illinois、美国、60068
- Lutheran General Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Patient must be a candidate for dynamic compression screw fixation of an intertrochanteric hip fracture.
- Patient must be 18 or older and have a life expectancy of at least 5 years beyond their enrollment.
- Patient must be able to provide written informed consent.
- Patient must agree to abide by the study protocol.
Exclusion Criteria:
- Patient must not have a concurrent illness that would make extended time under anesthesia a severe risk.
- Patient must not have a concurrent fracture in the same limb.
- Patient must not have a concurrent open fracture.
- Patient must not have a concurrent highly comminuted fracture or fractures that, in the surgeon's opinion, would allow excessive motion of the femoral shaft relative to the femoral head.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:单身的
合作者和调查者
调查人员
- 首席研究员:Thomas C. Kienzle, MD、Surgical Insights
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- R01 AR44759
- NIAMS-054
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.