High-Density Lipoprotein (HDL) Modulation and Endothelial Function
HDL Modulation and Endothelial Function
It is well known that lowering low-density lipoprotein (LDL) (bad cholesterol) is beneficial for decreasing heart attacks and death. More recently, focus has been on trying to raise HDL (good) cholesterol. The purpose of the present study is to determine if the addition of a sustained release preparation of niacin (Niaspan - a medicine to raise HDL cholesterol) to LDL lowering with a statin type medication results in improved vascular health. The study of the well being of one's vessel wall (endothelial function) will serve as a marker of treatment effect in the study.
Hypotheses: Extended-release (ER) niacin will improve endothelial function measured as brachial flow-mediated dilation (FMD - 10 end-point) and as pulse volume amplitude by pulse arterial tonometry (PAT) (20 end-point) in subjects with established atherosclerosis whose LDL cholesterol is optimally treated with statin therapy.
研究概览
详细说明
Purpose: To determine the incremental value of extended-release (ER) niacin in combination with high dose statin therapy on brachial endothelial function in subjects with coronary atherosclerosis.
Hypotheses:
- ER niacin will improve endothelial function measured as brachial flow-mediated dilation (FMD - primary end-point), hyperemic velocity and as pulse volume amplitude by PAT (20 end-point) in subjects with established atherosclerosis whose LDL cholesterol is optimally treated with statin therapy.
- Hyperemic pulse volume amplitude in the finger assessed by pulse arterial tonometry (PAT) will correlate with brachial FMD as assessed by high resolution ultrasound of the brachial artery.
Background: In patients with established coronary atherosclerosis, secondary prevention strategies with lipid lowering agents have resulted in event reductions of 25-30%. Despite aggressive cholesterol lowering with statins event rates remain 2-3% per year for subjects at high risk. While many new therapeutic targets have been suggested, recently there has been much interest in modulation of HDL cholesterol. Low HDL is a powerful risk factor for coronary events. HDL functions in the reverse cholesterol transport system to remove excess cholesterol from tissues including the vessel wall. In addition, HDL has other vascular benefits including anti-oxidant and direct endothelial effects. The most effective available way to modulate HDL is with niacin. An ER formulation of niacin (Niaspan - Kos) will be available in Canada in 2005 and has been shown to be efficacious and safe.
The endothelium plays a key role in vascular homeostasis through the release of paracrine factors such as nitric oxide. Dysfunction of the endothelium occurs in response to risk factors and atherosclerosis. Endothelial function can be readily measured non-invasively in humans and pharmacotherapy that has been shown to reduce cardiovascular events improves endothelium-dependent vasodilation. In addition, recent studies have suggested that measures of endothelial function have prognostic implications for subjects at risk for vascular events. As such the measurement of endothelial function has become well established as a surrogate marker of disease activity and will be utilized in the current study. The effect of niacin on endothelial function has not been studied.
Design: The study is a single center, randomized, placebo controlled cross-over design. An open label one month run in phase of atorvastatin therapy will be utilized to establish baseline endothelial function and ensure tolerability of the atorvastatin. Brachial ultrasound determination of FMD and pulse arterial tonometry (PAT) will be utilized. Open label atorvastatin will be continued throughout the study in all subjects. Following baseline measurements of endothelial function, patients will be randomized to placebo or escalating doses of ER niacin for a treatment phase of 3 months. At this point, repeat measurements will be undertaken and subjects will cross-over to the alternate therapy for an additional 3 months followed by final measurements. The use of different methods of endothelial function measurement will allow a comparison of the two.
Subjects will have established coronary atherosclerosis and an HDL < 1.1 mmol/L, and be at least one month post percutaneous coronary intervention (PCI) or 3 months post coronary artery bypass graft (CABG). Exclusion criteria include active gout, gallbladder or peptic ulcer disease, change of endothelial modulating drugs within one month of study initiation or use of niacin.
The primary end-point of the study is brachial artery flow-mediated vasodilation. The primary efficacy analysis will be a comparison of the change in FMD during active ER niacin treatment compared with baseline. The sample size is based on an expected 2% difference in FMD (SD 5%), p <0.05 and power of 80%.
Significance: Despite the reduction of mortality with current LDL lowering approaches, morbidity and mortality remain unacceptably high. HDL has recently gained favor as a therapeutic target to lower cardiovascular event rates. The current study will evaluate the effect of HDL raising on endothelial health, a surrogate marker of atherosclerosis activity.
研究类型
注册 (实际的)
阶段
- 第三阶段
联系人和位置
学习地点
-
-
Alberta
-
Calgary、Alberta、加拿大、T2N 2T9
- Foothills Medical Centre
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Aged 18-80 years
- Coronary artery disease
Exclusion Criteria:
- HDL > 1.10 (men), > 1.30 (women)
- PCI within 30 days or CABG within 90 days
- Symptomatic congestive heart failure (CHF)
- Uncontrolled hypertension
- Gout or active gallbladder disease, liver disease or peptic ulcer disease
- Diabetes (or if Fasting blood sugar > 7.0 then hemoglobin A1c [HbA1C] > 6.1 is exclusionary)
- Abnormalities of complete blood count (CBC), creatinine or ALT
- Change in endothelial modulating drugs in the last month or use of niacin
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:四人间
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Brachial artery flow mediated dilation
大体时间:12 weeks
|
12 weeks
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
Forearm pulse arterial tonometry (PAT)
大体时间:12 weeks
|
12 weeks
|
|
Peak hyperemic velocity
大体时间:12 weeks
|
12 weeks
|
合作者和调查者
调查人员
- 首席研究员:Todd J Anderson, MD、University Of Calgary
出版物和有用的链接
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.