Evaluation of Exposure Reduction Using Region-of-Interest Fluoroscopy (X-ray Fovea Imaging) in Cardiac Interventions
Trial to Determine Non-inferiority of Exposure Dose Reduction and Diagnostic Performance of Region-of-Interest Fluoroscopy (X-ray Fovea Imaging) Compared to Standard Fluoroscopy in Patients Undergoing Cardiac Interventional Procedures
研究概览
详细说明
X-ray catheterization is used to guide minimally invasive procedures including percutaneous coronary interventions (PCIs), involving diffuse and multiple vessel disease and total chronic occlusion as well as electrophysiology (EP) procedures. While the medical benefit to patients outweighs the procedural risk, long fluoroscopy times associated with complex interventions have resulted in acute radiation injuries to patients. Radiation induced cancers have also become a concern in younger patient populations. With the increased number, diversity and complexity of the interventions performed, there has been a growing interest in reducing the long-term exposure risk to medical personnel (interventionists).
Conventional methods to reduce in radiation exposure, however, impact and often degrade diagnostic image quality. Catheterization procedures focus on a small portion of the anatomy forming the central region of the image with the periphery providing contextual information. Thus, decreasing the image quality in periphery can provide an overall exposure reduction to patients and interventionists without impacting on diagnosis. This can be achieved by introducing a pre-patient region-of-interest (ROI) attenuator that collimates the primary x-ray beam, reducing exposure to peripheral regions and decreasing integral radiation to the patient and scatter radiation to the interventionist.
The goal of this study is to investigate the exposure dose reduction provided by ROI imaging to patients and interventionists undergoing catheterization and to examine the feasibility of using the ROI attenuator in routine clinical practice for future integration into commercial x-ray imaging systems. The aim is to obtain exposure dose data and cardiac angiography images from subjects undergoing routine interventional procedures performed with and without ROI attenuation (experimental and control groups, respectively). For the experimental group, the interventionists performing the procedure will determine the appropriate application of the ROI attenuator and the duration of its use on specific patient lesions. An internal pilot study will be initially conducted on approximately 30 patients (15 per group) to obtain estimates on patient and operator dose reduction and variability. The on-going clinical trial will then be performed on an additional 40 patients (where the final protocol procedures and recruitment will be refined based on results from the pilot study).
研究类型
注册 (预期的)
阶段
- 阶段1
联系人和位置
学习地点
-
-
Ontario
-
Toronto、Ontario、加拿大、M4N 3M5
- Sunnybrook Health Sciences Centre
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- The subject is greater than 18 years of age.
- The subject is currently planned for conventional cardiac interventional procedures (i.e. catheterization, percutaneous coronary intervention (PCI), electrophysiology (EP) ablations and procedures) as specified by his/her physician.
- The subject is able and willing to comply with study procedures, and signed and dated informed consent is obtained.
Exclusion Criteria:
- The subject is pregnant or trying to become pregnant.
- The subject requires urgent/emergent cardiac catheterization, PCI, and/or EP procedures as per treating physician.
- The subject has been previously included in the study.
学习计划
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
无干预:1
Subjects undergoing routine cardiac catheterization or interventional procedures using the standard fluoroscopy system.
|
|
|
实验性的:2
Subjects undergoing routine cardiac catheterization or interventional procedures using the region-of-interest fluoroscopy (x-ray fovea imaging) system.
|
Use of an experimental fluoroscopy system fitted with a region-of-interest attenuator (fovea) to evaluate or treat lesions during cardiac interventional procedures.
|
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
X-ray exposure area product, primary and scatter radiation to patient and interventionist and procedure and irradiation time for interventions performed without and with region-of-interest imaging (control and experimental arms, respectively).
大体时间:The outcome measure will be recorded per patient procedure. A comparison between control and experimental arms will be conducted after the pilot study (at ~1 to 2 months) and at end the full study (at ~4 to 6 months).
|
The outcome measure will be recorded per patient procedure. A comparison between control and experimental arms will be conducted after the pilot study (at ~1 to 2 months) and at end the full study (at ~4 to 6 months).
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
Quality and diagnostic benefit of images obtained without and with the region-of-interest imaging.
大体时间:Retrospective expert comparison of images from patient procedures (between control and experimental arms) will occur within 1 to 3 months after the completion of the pilot study and the full study.
|
Retrospective expert comparison of images from patient procedures (between control and experimental arms) will occur within 1 to 3 months after the completion of the pilot study and the full study.
|
合作者和调查者
合作者
调查人员
- 首席研究员:Alexander J Dick, MD、Sunnybrook Health Sciences Centre
- 研究主任:Normand Robert, PhD、Sunnybrook Health Sciences Centre
- 学习椅:John A Rowlands, PhD、Sunnybrook Health Sciences Centre
研究记录日期
研究主要日期
学习开始
初级完成 (预期的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他相关的 MeSH 术语
其他研究编号
- 005-2008
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.