Pulse Pressure Variation Helps to Predict Fluid Responsiveness in Patients Ventilated With Low Tidal Volumes

2012年4月2日 更新者:Hospital de Clinicas de Porto Alegre

Objective: To determine the value of pulse pressure variation (ΔRESPPP) to predict fluid responsiveness in patients ventilated with low tidal volumes (VT), and to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.

Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.

The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.

The study hypothesis is not a good predictor of fluid responsiveness in patients ventilated with low tidal volumes.

研究概览

地位

完全的

详细说明

Volume expansion is frequently used to treat critically ill patients with acute circulatory failure. The goal of volume expansion is to increase left ventricular stroke volume and consequently cardiac output. However, about 50% of patients with acute circulatory failure will respond to fluid challenge (preload- dependent patients). Therefore, the ability to predict fluid responsiveness in critically ill patients is crucial, particularly for ARDS patients because of increased alveolar-capillary membrane permeability, and avoiding unnecessary fluid loading has been shown to have a positive effect on patient outcome.Among the dynamic parameters used at the bedside to identify fluid responsiveness, pulse pressure variation (ΔRESPPP) is one of the most accurate in patients with acute circulatory failure receiving invasive mechanical ventilation. However, most studies evaluated patients ventilated with large tidal volumes (≥ 8 ml/kg). Therefore, the validity of ΔRESPPP to identify fluid responsiveness is still debated when lower tidal volumes are used.

The current literature about its performance during ventilation with low tidal volumes is unclear, and opposite conclusions have been drawn. The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.

Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.

Patients were followed for 28 days or until discharge from the ICU.

Study Protocol Patients were sedated with midazolan and fentanyl (score of -4 to -5 in the Richmond Agitation Sedation Scale)and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT < 8 ml/kg IBW (51 + 0.9[height in cm- 152.9] for men and 45.5 + 0.91[height in cm- 152.9] for women). Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Zero pressure was measured at the midaxillary line. The correct position of the pulmonary artery catheter in West's zone 3 was checked as described in the literature.

Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution (n=36) or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes (n=2).

Hemodynamic Parameters

Variations in arterial pulse pressure were visualized on bedside monitors (HP S66 and PHILIPS IntelliVue, MP60, Germany) and measured with the cursor for each of 5 breathing cycles. ΔRESPPP was calculated using the following equation:

ΔRESPPP (%) = 100 x (PPmax - PPmin) / [(PPmax + PPmin)/2]

where PPmax and PPmin are the maximal pulse pressure at inspiration and the pulse pressure obtained on expiration, respectively.

A pulmonary artery catheter (Edwards Healthcare, Irvine, CA) was used to measure cardiac output according to the thermal dilution method (3 injections of 10ml 0.9% saline solution), systolic, diastolic and mean pulmonary arterial pressures, pulmonary artery occlusion pressure (PAOP, mmHg), central venous pressure (CVP, mmHg), and mixed venous saturation (SvO2). Mean arterial pressure (MAP, mmHg), measured using the arterial line, and heart rate (HR, bpm) were also recorded. All measurements were made at the end of expiration, before and after FC. Patients were defined as fluid responders when cardiac index increased at least 15% of baseline value.

Ventilation Parameters The following ventilatory parameters were measured: inspiratory and expiratory tidal volume, respiratory rate (RR), plateau pressure (cmH2O), peak pressure (cmH2O), total positive end-expiratory pressure (PEEPtot), static compliance (Cst) and driving pressure (DP= Pplat-PEEP). All measurements were made before and after FC.

Statistical Analysis Sample size was defined as 38 patients for estimation of the correlation between CI and ΔRESPPP 0.5 (moderate to high magnitude), with a level of significance of 0.05 and power of 90%.

The effects of FC on hemodynamic parameters were assessed using a paired Student's t-test for normally distributed variables or a nonparametric Wilcoxon Signed Rank test for non-normally distributed variables. The comparison of hemodynamic parameters between both groups at baseline and after FC was assessed using a two sample Student's t-test or a nonparametric Mann-Whitney U test. Results were expressed as mean values±SD or median (25-75 percentiles).

Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of ΔRESPPP, ΔRESPPP/DP, CVP and PAOP to predict fluid responsiveness. The best cut-off value for ΔRESPPP ROC curve was determined for the entire population. In addition, measures of diagnostic performance were calculated: sensitivity, specificity, predictive values and likelihood ratio. Linear correlations were tested using the Spearman rank method. Data were analyzed using SPSS 15.0. A p value <0.05 was considered significant.

研究类型

观察性的

注册 (实际的)

38

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Rio Grande do Sul
      • Porto Alegre、Rio Grande do Sul、巴西、90035903
        • Hospital de Clinicas de Porto Alegre

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

16年 及以上 (孩子、成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

概率样本

研究人群

Patients age ≥ 16 years, from both genders, admitted to the HCPA ICU, receiving invasive mechanical ventilation, with hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure > 90 mm Hg; with arterial line in place (radial or femoral) and pulmonary arterial catheter in place.

描述

Inclusion Criteria:

  • Age ≥ 16 years
  • Hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure > 90 mm Hg
  • Arterial line in place (radial or femoral)
  • Pulmonary arterial catheter in place

Exclusion Criteria:

  • Presence of cardiac arrhythmias
  • Presence of pneumothorax
  • Presence of heart valve disease or intracardiac shunt
  • Previously diagnosed right ventricular insufficiency

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 观测模型:队列
  • 时间观点:横截面

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Increase in cardiac index at least 15% of baseline value.
大体时间:Cardiac index was measured at the end of a 30 minutes fluid challenge.
Patients were sedated and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT < 8 ml/kg ideal body weight. Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes. The increase in cardiac index was measured immediately after fluid challenge.
Cardiac index was measured at the end of a 30 minutes fluid challenge.

次要结果测量

结果测量
措施说明
大体时间
Mortality
大体时间:28 days
Patients were followed for 28 days or until ICU discharge
28 days

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Gilberto Friedman、Hospital de Clinicas de Porto Alegre

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2006年5月1日

初级完成 (实际的)

2009年10月1日

研究完成 (实际的)

2009年10月1日

研究注册日期

首次提交

2012年3月14日

首先提交符合 QC 标准的

2012年4月2日

首次发布 (估计)

2012年4月3日

研究记录更新

最后更新发布 (估计)

2012年4月3日

上次提交的符合 QC 标准的更新

2012年4月2日

最后验证

2012年3月1日

更多信息

与本研究相关的术语

其他研究编号

  • 06-109

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅