The Effect of Replacement Frequency of Electrodes on Skin in Infant

2021年10月21日 更新者:Zehra Kan Onturk、Acibadem University

The Effect of Replacement Frequency of Electrodes on Skin Moisture and Condition in Infants Hospitalized in the Pediatric Intensive Care Unit

In the Pediatric Intensive Care Unit (PICU), each child and infant is monitored to determine the status of the underlying disease by constantly monitoring the main variables, to help diagnosis and to guide treatment. During the monitoring application, electrodes of appropriate size for the patient's age and body surface are attached to the appropriate areas of the patient where skin integrity is intact, clean, and dry. It is recommended that these electrodes be replaced within 24 hours at most, but there is no evidence of the effect of electrode replacement frequency on skin moisture and integrity.

Based on this reason, this study was conducted experimentally in a randomized controlled manner to determine the effect of frequency of monitoring electrode replacement on skin moisture and condition of infants hospitalized in the PICU.

研究概览

详细说明

The study was conducted with 66 participants, with the number of participants being 33 in both two groups (Experimental and Control Group).The randomization of the sample was determined by entering the total number of cases in line with the Research Randomizer program.

The control group of the study involved infants whose monitoring electrodes were replaced at the 24th hour after being monitored and the experimental group involved infants whose monitoring electrodes were replaced at the 12th and 24th hour after being monitored.

Before all participants are monitored, skin cleansing was performed on the right second intercostal space (Right 2nd ICA), left second intercostal space (Left 2nd ICA) and the left lower side of the sternum at the left midclavicular level in the fifth intercostal space (Midclavicular 5th ICA). After that, skin moisture was measured where monitoring will be performed and skin condition evaluation of these areas. Then the participants were monitored.

After these applications, skin moisture and skin condition score evaluations were repeated in both groups.

Skin Condition Score The skin condition score, developed by the Association of Women's Health, Obstetric and Neonatal Nurses (AWHONN) and validated by Calisir et al. in 2016, was used to determine the skin condition. The scale consists of three items and each item includes an evaluation criterion. These are dryness, erythema, and skin integrity breakdown/peeling, respectively. Each item of the 3-point Likert scale gets 1 to 3 points. The lowest score that can be obtained from the scale is 3, the highest score is 9. A high total score indicates that the skin condition of the newborn is poor. Permission was obtained for the use of the skin condition score from the Association of Women's Health, Obstetric and Neonatal Nurses (AWHONN) and the authors who performed the Turkish validity and reliability.

Skin Moisture Digital Moisture Monitor For Skin was used to measure skin moisture. This moisture measuring device measures with "%". This device developed for precise measurement has been preferred because of its ability to show the amount of moisture by the contact without damaging the skin, being portable, working with a battery, having a wide measurement range (it can measure the amount of skin moisture from 0% to 99.9%), because of its fast, easy and reliable use, low cost, and its ability to measure in many anatomical regions.

Materials provided in accordance with the procurement procedure of the institution where the research was conducted and used in patient care during the data collection phase were preferred as consumable materials.

Researchers do not have any conflict of interest with companies regarding the preference of these materials. The consumables that are still used in the institution.

研究类型

介入性

注册 (实际的)

33

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Istanbul、火鸡
        • Acıbadem University Atakent Hospital

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

1个月 至 1年 (孩子)

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Patients whose parents agreed to participate in the study and signed the informed consent form
  • No history of surgical procedures
  • Recently admitted to the unit and monitored for the first time
  • Infants aged ≥ 1 to 12 ≤ months

Exclusion Criteria:

  • Infants with a skin disease, with other diseases that can affect skin moisture and condition, with immune system disease

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:支持治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
其他:Control group (replacement every 24 hours)
The monitoring electrodes were not replaced for 24 hours, the electrodes were removed at the end of 24 hours (the protocol currently used in the institution) in control group.

Processing Steps:

  1. The monitoring electrodes were not replaced for 24 hours, the electrodes were removed at the end of 24 hours. During the 24-hour follow-up, patients whose electrodes were removed for any reason were excluded from the sample.
  2. Immediately after the drying, skin moisture measurement was made in the right 2nd intercostal space (ICA), left 2nd ICA, and midclavicular 5th ICA regions.
  3. The skin condition was evaluated from the areas monitored using the skin condition score by the researcher and another independent observer.
  4. The data were recorded.
实验性的:Experimental Group (replacement every 12 hours)
In the experimental group, the monitoring electrodes were replacement every 12 hours within 24 hours.

Processing Steps:

  1. Monitoring electrodes were removed at the end of the 12th hour. When removing the monitoring electrodes, the area was first wetted using a disinfectant and dried using a sponge after removing the electrodes.
  2. Immediately after the drying, skin moisture measurement was made in the right 2nd ICA, left 2nd ICA and midclavicular 5th ICA regions.
  3. The skin condition was evaluated from these areas monitored using the skin condition score by the researcher and another independent observer.
  4. Monitored again.
  5. Monitoring electrodes were removed at the end of the 24th hour. Cleaning and drying were done immediately after removal.
  6. Immediately after drying, skin moisture was measured from the monitored areas.
  7. The skin condition was evaluated from the areas monitored using the skin condition score by the researcher and another independent observer.
  8. The data were recorded.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in skin moisture
大体时间:Data collected immediately before monitoring, after monitoring 12th hour (only for experimental group) and after 24 th hours. The change in these time intervals assessed.

Digital Moisture Monitor For Skin was used to measure skin moisture. This moisture measuring device measures with "%". This device developed for precise measurement has been preferred because of its ability to show the amount of moisture by the contact without damaging the skin, being portable, working with a battery, having a wide measurement range (it can measure the amount of skin moisture from 0% to 99.9%). As the moisture in the skin increases, the % increases.

Skin moisture measurement was made in the right 2nd ICA, left 2nd ICA, and midclavicular 5th ICA regions.

Data collected immediately before monitoring, after monitoring 12th hour (only for experimental group) and after 24 th hours. The change in these time intervals assessed.
Change in skin condition
大体时间:Data collected immediately before monitoring, after monitoring 12th hour (only for experimental group) and after 24 th hours. The change in these time intervals assessed.
Skin condition were evaluated with the Skin Condition Assessment Scale. The scale consists of three items and each item includes an evaluation criterion. These are dryness, erythema, and skin integrity breakdown/peeling, respectively. Each item of the 3-point Likert scale gets 1 to 3 points. The lowest score that can be obtained from the scale is 3, the highest score is 9. A high total score indicates that the skin condition of the newborn is poor.
Data collected immediately before monitoring, after monitoring 12th hour (only for experimental group) and after 24 th hours. The change in these time intervals assessed.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2018年8月31日

初级完成 (实际的)

2019年6月17日

研究完成 (实际的)

2019年6月17日

研究注册日期

首次提交

2021年8月16日

首先提交符合 QC 标准的

2021年8月16日

首次发布 (实际的)

2021年8月23日

研究记录更新

最后更新发布 (实际的)

2021年10月26日

上次提交的符合 QC 标准的更新

2021年10月21日

最后验证

2021年10月1日

更多信息

与本研究相关的术语

其他研究编号

  • ATADEK-2018/11

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.