此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Analyzing the Effect of Air Polishing on Tooth Surfaces With Two Imaging Methods

2022年1月5日 更新者:Vecihe Merve Balta Uysal、Kocaeli University

Analyzing the Effect of Sodium Bicarbonate and Glycine Air Polishing on Tooth Surfaces With Two Different Imaging Methods

Micro-CT is a non-destructive imaging method with high resolution and allows to examine all tooth structures individually. Pre- and post-application images obtained by micro-CT can be superimposed and differences can be precisely detected. Intraoral scanners in CAD/CAM systems also provide non-destructive image scanning. CAD/CAM are systems that are widely used in dentistry today. Access to the device is easier than micro-CT. This study was focused on to compare two different imaging methods by assessing changes caused by sodium bicarbonate and glycine air polishing on the tooth surfaces.

研究概览

地位

完全的

条件

详细说明

The patients were recruited from individuals seeking periodontal and/or dental treatment at Kocaeli University, Faculty of Dentistry. The teeth samples were collected from the participants who have a single-rooted tooth with the gingival recession on all surfaces and need to be extracted. All patients who met the criteria were informed about the study. Patients who gave written informed consent were included. Before the teeth extractions, root surfaces were marked with a bur at the level of the gingival margin. Extractions were performed under local anesthesia with 2% xylocaine adrenalin. Fourteen single root extracted teeth were included into the study. The crown and exposed root surface were air polished using glycine and sodium bicarbonate powders at instrumentation time of 5s, combinations of medium and maximum power and medium water settings, distance of 5mm and angulation of 60 degree.

Samples were scanned before and after air polishing with a high-resolution micro-CT device. The scanning conditions were 100 kVp; 100-mA, 0.5-mm Al/Cu filter; 13.1-μm pixel size; and rotation at 0.2 steps. According to the manufacturer's instructions, each sample was rotated 360°. The mean scanning time was around 1hour. The teeth surfaces were digitalized before and after air polishing with an intraoral scanner. The mean scanning time was around 10 second. The virtual images of the scanned teeth were saved in stereolithography (STL) format. The defect volume was estimated.

The data were analyzed using commercially available statistical analysis software. Descriptive statistics that were used to analyze the results included the mean, standard deviation, median, minimum, and maximum. Mann-Whitney U test was performed to compare differences between two independent variables. Wilcoxon test was used to compare differences between two dependent variables. P-values less than 0.05 were considered statistically significant.

研究类型

观察性的

注册 (实际的)

14

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Kocaeli、火鸡、41190
        • Kocaeli University, Faculty of Dentistry

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

是的

有资格学习的性别

全部

取样方法

非概率样本

研究人群

The patients were recruited from individuals seeking periodontal and/or dental treatment at Kocaeli University, Faculty of Dentistry.

描述

Inclusion Criteria:

Being older than age of 18, Willing to participate the study, To have a single rooted tooth with gingival recession on all surfaces and need to be extracted, The tooth has to be free of caries, defects and restorations.

Exclusion Criteria:

Have history of infectious diseases like Hepatitis and/or HIV (+).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Micro-CT
Samples were scanned before and after air polishing with a high-resolution micro-CT device. The scanning conditions were 100 kVp; 100-mA, 0.5-mm Al/Cu filter; 13.1-μm pixel size; and rotation at 0.2 steps. According to the manufacturer's instructions, each sample was rotated 360°. The mean scanning time was around 1hour.
Micro computed tomography (micro-CT) is an imaging method in which cross-sectional images are obtained and these images are transferred to the computer through specific software, processed and stored.
CAD/CAM
The teeth surfaces were digitalized before and after air polishing with an intraoral scanner. The mean scanning time was around 10 second. The virtual images of the scanned teeth were saved in stereolithography (STL) format.
CAD/CAM (computer aided design-computer aided manufacturing) is a production method that is frequently used in many areas of technology. These systems are composed of a data acquisition unit, software for designing virtual restoration, and a computerized milling device.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Defect volume
大体时间:5 second
The teeth were divided into two groups, the crown and exposed root surface were air polished using glycine and sodium bicarbonate powders at instrumentation time of 5s, combinations of medium and maximum power and medium water settings, distance of 5mm and angulation of 60 degree. Samples were scanned in a micro-computed tomography (micro-CT) and CAD/CAM at baseline and then after powder treatment and the defect volume was estimated.
5 second

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2020年6月17日

初级完成 (实际的)

2020年8月17日

研究完成 (实际的)

2020年9月14日

研究注册日期

首次提交

2022年1月5日

首先提交符合 QC 标准的

2022年1月5日

首次发布 (实际的)

2022年1月19日

研究记录更新

最后更新发布 (实际的)

2022年1月19日

上次提交的符合 QC 标准的更新

2022年1月5日

最后验证

2022年1月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • KOU GOKAEK 2020/08.07

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

是的

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅