Image Evaluation of Intalight Dream OCTA Scans With Optos FA & ICGA Images (OCTA & FA)

2026年4月28日 更新者:Intalight, Inc
The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Image assessment will be conducted by three expert image graders and involve the assessment of the images based on both image quality and clinical utility. Evidence for substantial equivalence will be obtained through establishing similar image evaluation results across the devices based on image quality and clinical utility.

研究概览

地位

招聘中

干预/治疗

详细说明

1. Protocol Summary

The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Image assessment will be conducted by three expert image graders and involve the assessment of the images based on both image quality and clinical utility. Evidence for substantial equivalence will be obtained through establishing similar image evaluation results across the devices based on image quality and clinical utility.

Objectives and Endpoints

The primary objective is to evaluate image quality and clinical utility for visualization of the retinal vasculature from en-face OCTA scans between the VG200D and FA and ICGA images from the CA SLO device in eyes with retinal pathology.

The endpoint is the image grading results of the scans of the vascular structure of the retina in eyes with retinal associated pathology.

Methods

This is a prospective comparative study that will be conducted at one clinical site in the United States, in which subjects who sign an informed consent form and fulfil all inclusion and exclusion criteria will have images obtained using the investigational study device and the predicate device (VG200D and CA respectively).

This study will employ one VG200D device and one Optos CA device. At least one acceptable scan will be captured for each subject on each device. Scans will be assessed at the time of capture by the operator for acceptable quality, poor quality scans will be retaken. All scans will be saved and both acceptable and unacceptable scans will be recorded on the CRF. For FA and ICGA scans, the CA device captures multiple images over the time-course of the dye filling the arteries and veins, however the operator and/or investigator will review and choose the most clinically appropriate image to use for evaluation.

Subjects enrolled in this study will be confirmed to have retina associated pathology at the time of the study visit and will be in need of an FA and/or ICGA scan. Ocular status will be confirmed by a clinical examination during the study visit. Subjects enrolled may have more than one ocular pathology. Acceptable retina associated pathologies may include but are not limited to: Age-related macular degeneration, Diabetic Retinopathy with or without DME, and/or Vein or artery occlusions, that require FA or ICGA imaging.

If both eyes qualify, the study eye will be selected by the Investigator based on retinal pathology, where the study eye will have more significant pathology. If only one eye qualifies, that eye will be the study eye. Device imaging order will be randomized.

All scans are reviewed for acceptable image quality by the operator at the time of image acquisition based on user manual described criteria and as described in section 7.1.1 below. Operators will use the pre-defined, objective criteria described in section 7.1.1 below for how images are included into or excluded from the final data set and will be applied by the device operators using pre-defined image quality parameters, such as the signal strength (for OCTA images), poor illumination or contrast (for SLO images), presence of blinks, eye-movements, clipping, etc. These criteria will be applied to all scans at the time of capture by the operator and/or investigator. Acceptable scans will solely be determined by the operator and investigator. The number of scans that are rejected for all devices will be recorded in the CRF and the reasons for rejection will be provided. Image accountability of all scans will be reported in the final clinical study report.

The VG200D has more than one OCTA scan pattern available and all OCTA scan patterns for the VG200D will be captured for image evaluation. The first acceptable OCTA scan from each scan pattern captured will be used for the en-face OCTA visualization assessment.

The en-face OCTA images will be assessed and graded by three experienced graders and scored for image quality and clinical utility as compared to a similar grading of the Optos CA FA and ICGA images.

Image Grading

OCTA en-face images and FA and ICGA images will be exported and evaluated by three masked graders in a masked and randomized fashion for image quality and clinical utility. Image graders will have experience in both OCTA images and FA and ICGA images and will be independent from the clinical research site operator and investigator. Grading will be masked and randomized. Graders will work independently evaluating a single image at a time for the FA and/or ICGA images and will review all OCTA depth slabs for the OCTA scans. For OCTA scans, where multiple images at various depths are available, all depth scans (slabs) will be reviewed together for that patient and an overall image assessment will be provided (i.e., a Gestalt assessment will be made based on all images).

All graders will score each image for general image quality on a five-point scale from 0-5 where scores of 0 indicate image failure, 1 indicates very poor image quality, 2 indicates poor image quality, 3 indicates average image quality, 4 indicates good image quality, and 5 indicates excellent image quality. Scores of 0, 1 and 2 indicate the images have unacceptable image quality, and scores of 3, 4 and 5 indicate the images have acceptable image quality. In addition, images will be graded for clinical utility in helping to aid clinical decisions, such as viewing normal structures (confirming absence of pathology) or detecting pathological changes in the images (confirming pathology). The graders will evaluate clinical utility based on image content (e.g., identifying key vascular features such as the foveal avascular zone border, large-, medium-, and small-sized blood vessels, and blind-end capillaries; key pathologic vascular features such as microaneurysms, neovascular networks, telangiectasias, capillary dropout or nonperfusion, etc. En face depth sections (thickness slabs) from all available depths will be assessed together. The clinical utility or usefulness of OCTA images will also be graded on a five-point scale from 0-5 where scores of 0 indicate no clinical information is present, 1 indicates clinical information is very poor and not helpful, 2 indicates clinical information is poor and not helpful, 3 indicates clinical information is average but helpful, 4 indicates clinical information is good and helpful, and 5 indicates the clinical information present is excellent and very helpful. Scores of 0, 1 and 2 indicate the images are not clinically helpful and are considered unacceptable for providing useful clinical information. Scores of 3, 4 and 5 indicate the images are adding useful clinical information for aiding clinical decisions and are acceptable.

Planned Analyses

Results will be analyzed for differences using the non-parametric Wilcoxon signed rank test. In addition, the percentage agreement between each pair of readers will be determined by using 2x2 tables for the binary outcomes of acceptable vs. not acceptable.

Analysis of Safety Any adverse event (AE) associated with the VG200D or the predicate devices will be used to evaluate safety. Adverse event definitions and reporting requirements are provided in the study Protocol. All adverse events will be reported in the clinical study report.

研究类型

观察性的

注册 (估计的)

30

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

取样方法

非概率样本

研究人群

Patients with retina pathology

描述

Inclusion Criteria:

  • Subjects 22 years of age or older on the date of informed consent
  • Subjects able to understand the written informed consent and willing to participate as evidenced by signing the informed consent
  • BCVA 20/400 or better in the study eye
  • Diagnosis of retinal associated pathology by investigator with the need to have an FA and/or ICGA performed in at least one eye

Exclusion Criteria:

  • Subjects unable to tolerate ophthalmic imaging
  • Subjects not able to obtain acceptable OCT images due to ocular media opacity or other reasons
  • Subject has a condition or is in a situation which the investigator feels may put the subject at significant risk, may confound the study results, or may interfere significantly with the subject's participation in the study

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Eyes with retina pathology
These are eyes with some type of retina pathology such as age-related macular degeneration, diabetic retinopathy, diabetic macula edema, and other retina pathologies
This study employs the Dream OCT to image the eyes of patients with retina pathology

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Image assessment of retinal images
大体时间:All images and clinical study data will be collected in one clinical visit, which typically should take approximately 1 hour.
The outcome measure is the image grading of retinal images including OCTA and FA and or ICGA images as graded by experts
All images and clinical study data will be collected in one clinical visit, which typically should take approximately 1 hour.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年3月25日

初级完成 (估计的)

2026年7月15日

研究完成 (估计的)

2026年8月31日

研究注册日期

首次提交

2026年4月15日

首先提交符合 QC 标准的

2026年4月28日

首次发布 (实际的)

2026年5月6日

研究记录更新

最后更新发布 (实际的)

2026年5月6日

上次提交的符合 QC 标准的更新

2026年4月28日

最后验证

2026年4月1日

更多信息

与本研究相关的术语

其他研究编号

  • DREAM-CP2026-002

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

是的

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅