Virtual Reality-Assisted Nursing Intervention During Intrauterine Device Insertion (VR-IUD)
Effect of Virtual Reality-Assisted Nursing Intervention on Pain and Anxiety During Intrauterine Device Insertion: A Randomized Controlled Trial
This randomized controlled trial evaluated the effects of a virtual reality-supported nursing intervention based on Kolcaba's Comfort Theory on women's comfort, emotional state, pain and physiological parameters during intrauterine device insertion. Seventy women attending a family planning clinic were individually randomized by lottery to a virtual reality group, who received the intervention in addition to routine care, or to a control group, who received routine care only.
研究概览
地位
详细说明
Study hypotheses
Compared with the control group (routine care without virtual reality), women receiving the virtual reality-assisted nursing intervention (experimental group):
- experience a lower level of pain during the procedure;
- experience lower levels of anxiety during the procedure;
- exhibit a lower stress response in physiological parameters (pulse rate, blood pressure and respiratory rate);
- experience higher levels of comfort during the procedure. Condition: Pain, anxiety, physiological parameters and comfort of women during intrauterine device (IUD) insertion Intervention: Virtual reality-assisted nursing intervention Population: Women who have decided to have an IUD inserted Note on outcomes: In the initial registration, pain was erroneously listed as the primary outcome. The primary outcome of this trial is overall comfort, measured with the General Comfort Scale total score before and after the procedure. This was corrected on October 30, 2026. Pain was assessed at all planned time points and is reported as a secondary outcome.
Study Design Study type: Interventional (clinical trial) Design: Single-center, prospective, two-arm, parallel-group randomized controlled trial Allocation: Randomized (1:1) Masking: None (open label). Because of the nature of the intervention, participants, the nurse researcher delivering the intervention and the practitioners could not be blinded. Data were coded before analysis, and the analyses were performed by a researcher who was not involved in data collection.
Setting: Family planning outpatient clinic of a women's and children's hospital, Gaziantep, Türkiye Study period: October 2024 to March 2025 Sample Size The sample size was calculated with G*Power 3.1.9.4 for a repeated-measures analysis of variance (two groups, two measurements), with a significance level of 5% (alpha = 0.05), a power of 95% and an effect size of f = 0.40. The minimum required sample was 64 women (32 per group). To allow for possible data loss, the target sample was set at 70 women (35 per group).
Participant Flow Eighty-nine women who agreed to participate were assessed for eligibility. Nineteen did not meet the eligibility criteria (visual impairment, n = 5; psychiatric disorder, n = 2; severe dizziness, n = 4; analgesic use before the procedure, n = 8). The remaining 70 women were randomized (experimental group = 35, control group = 35). No participant withdrew or was lost to follow-up, and all 70 women were included in the analysis.
Randomization and Groups Participants were individually randomized in a 1:1 ratio to the experimental or control group by lottery. Seventy identical slips of white paper, 35 labeled "experimental group" and 35 labeled "control group," were placed in a bag. After giving written informed consent and completing the baseline assessments, and before IUD insertion, each eligible woman drew one slip from the bag; drawn slips were not returned.
Given the nature of the intervention, information exchange between participants (contamination) could have influenced the results. To minimize this risk, women waited in a separate waiting area before the procedure, were called into the procedure room individually and, after the procedure, left the clinic through a separate exit that did not lead back to the waiting area.
Baseline characteristics of the groups were compared statistically, and baseline-adjusted analyses were used to account for any imbalances.
Note: An earlier version of this record described day-based allocation. This description has been corrected to reflect the individual lottery-based randomization that was actually implemented.
Intervention Experimental group (virtual reality group): In addition to routine care, women received a virtual reality-assisted nursing intervention based on Kolcaba's Comfort Theory. The nurse researcher prepared each woman for the procedure and used virtual reality to increase her comfort and reduce her anxiety. Women watched a nature-themed 360-degree video (water, forest and sky scenes) with soothing music, lasting approximately 6 minutes, through a virtual reality headset. The video was started 2 minutes before insertion and continued until it ended after insertion. The intervention was designed as a non-pharmacological nursing intervention to divert attention away from the procedure and to reduce pain and anxiety.
Control group (routine care): Women received routine care according to the clinic's standard practice, without virtual reality or any other study intervention.
All participants received a copper IUD inserted by the practitioners on duty. Materials
- Virtual reality headset: Samsung Gear VR (SM-R321NZWATUR), used with a smartphone
- Virtual reality video: "Virtual Nature 360° - 5K Nature Meditation for Daydream, Oculus, Gear VR," featuring nature scenes accompanied by calming music Data Collection Data were collected by trained researchers through face-to-face interviews in three phases; each session took approximately 15 to 20 minutes.
Before the procedure: Descriptive Characteristics Questionnaire; General Comfort Scale; visual analogue scales for anticipated pain, tension, fear/anxiety, irritability and contentment; blood pressure, pulse rate and respiratory rate. Allocation slips were drawn after these assessments.
During the procedure: pain (visual analogue scale) and pulse rate immediately after speculum insertion, tenaculum application and IUD placement.
After the procedure (5 minutes): blood pressure, pulse rate and respiratory rate; visual analogue scales for pain, tension, fear/anxiety, irritability and contentment; General Comfort Scale. Procedure duration (minutes), practitioner satisfaction and adverse events (such as dizziness, nausea and headset discomfort) were also recorded.
Vital signs were measured in both groups by the same researcher with the same device.
Data Collection Instruments Descriptive Characteristics Questionnaire: Prepared by the researchers on the basis of the literature; it covers age, education, employment, income, health insurance, obstetric history, current contraceptive use and its duration, previous IUD use, the person who decided on IUD use and negative information about IUDs received from the social environment.
General Comfort Scale: Developed by Kolcaba and adapted into Turkish, the scale consists of 48 four-point Likert-type items in three subscales (relief, ease and transcendence). Negative items are reverse-scored. Total scores range from 48 to 192, and higher scores indicate greater comfort. Cronbach's alpha was 0.85 for the Turkish version.
Visual analogue scales: Tension, fear/anxiety, irritability and contentment were each rated on a 100-mm scale from 0 (none) to 100 (most intense). Pain was rated on a 100-mm scale from 0 (no pain) to 100 (worst imaginable pain). Before the procedure, women rated on the same scale the pain they expected to feel during insertion (anticipated pain). The practitioner rated satisfaction with the procedure on a 100-mm scale from 0 (not at all satisfied) to 100 (completely satisfied).
Ethics Ethical approval was obtained from the SANKO University Clinical Research Ethics Committee (Decision No. 2023/24; December 21, 2023), together with institutional permission. The study followed the Declaration of Helsinki. Participants were informed about the aims and procedures of the study, and written informed consent was obtained from all participants.
Statistical Analysis Data were analyzed with IBM SPSS Statistics 25.0. Normality was assessed by skewness and kurtosis, homogeneity of variances by Levene's test and homogeneity of covariance matrices by Box's M test. Baseline characteristics were compared with the chi-square, Fisher's exact or Fisher-Freeman-Halton exact test and the independent-samples t-test, and standardized mean differences were calculated.
Intervention effects were estimated with analysis of covariance (ANCOVA), using the post-procedure score as the dependent variable, group as the fixed factor and the baseline score as the covariate (anticipated pain for pain after the procedure). ANCOVA assumptions (linearity, homogeneity of regression slopes, normality and homogeneity of residuals, influential observations) were checked. Sensitivity analyses included additional covariates for imbalanced baseline characteristics, heteroscedasticity-consistent (HC3) standard errors and a mixed-design repeated-measures ANOVA (group x time).
Variables not suitable for parametric testing (irritability, pain, procedure duration and practitioner satisfaction) were compared with the Mann-Whitney U test, and within-group change in pain with the Wilcoxon signed-rank test. Intraprocedural pain was compared with the Mann-Whitney U test and intraprocedural pulse rate with ANCOVA adjusted for baseline pulse rate. All tests were two-sided, and p < 0.05 was considered significant.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Gaziantep、土耳其(türkiye)、27270
- Women's and Children's Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
Aged 18 years or older Sexually active Decided to undergo intrauterine device insertion after routine contraceptive counseling Suitable candidate for intrauterine device insertion on gynecological examination No communication difficulties
Exclusion Criteria:
Visual or hearing impairment Diagnosed psychiatric disorder Severe facial injury History of epilepsy or severe dizziness Analgesic use before the procedure Any contraindication to intrauterine device insertion
学习计划
研究是如何设计的?
设计细节
- 主要用途:支持治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Virtual reality group
Intervention Type: Behavioral Intervention Name: Virtual reality-supported nursing intervention Other Intervention Names: VR-supported nursing intervention Assign to Arm: Experimental: Virtual reality group Description:Routine care plus the virtual reality-supported nursing intervention during IUD insertion. In addition to routine care, women received a virtual reality-supported nursing intervention based on Kolcaba's Comfort Theory. The nurse prepared each woman for the procedure and used virtual reality to increase comfort and reduce anxiety. Women watched a nature-themed 360-degree video with relaxing music (approximately 6 minutes) through a head-mounted display (Samsung Gear VR), started 2 minutes before insertion and continued until the video ended. |
Intervention Name: Virtual Reality Intervention Description: Participants in the experimental group received a virtual reality-assisted nursing intervention during intrauterine device insertion. A virtual reality headset was used to present a 3D immersive video including relaxing natural scenes and calming background music. The intervention was applied continuously throughout the procedure to distract attention from the procedure and reduce pain and anxiety. Intervention Name: Routine Care Description: Participants in the control group received routine care during intrauterine device insertion without the use of virtual reality or any additional distraction method. |
|
无干预:Control Group
Arm Title Control group Arm Type No Intervention Arm Description Routine care according to the clinic's standard practice, without virtual reality or any other study intervention. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
General Comfort Scale total score
大体时间:Before IUD insertion (baseline) and 5 minutes after the procedure
|
Overall comfort was measured with the Turkish version of Kolcaba's General Comfort Scale, which consists of 48 items rated on a four-point Likert scale. Total scores range from 48 to 192, with higher scores indicating greater comfort. |
Before IUD insertion (baseline) and 5 minutes after the procedure
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
General Comfort Scale subscale scores (relief, ease and transcendence)
大体时间:Before IUD insertion (baseline) and 5 minutes after the procedure
|
Scores of the relief, ease and transcendence subscales of the General Comfort Scale; higher scores indicate greater comfort. |
Before IUD insertion (baseline) and 5 minutes after the procedure
|
|
Emotional state scores (tension, fear/anxiety, irritability and contentment)
大体时间:Before IUD insertion (baseline) and 5 minutes after the procedure
|
Each emotional state was rated on a single-item 100-mm visual analog scale ranging from 0 (none) to 100 (most intense). |
Before IUD insertion (baseline) and 5 minutes after the procedure
|
|
Pain intensity (visual analog scale)
大体时间:Before the procedure (anticipated pain); immediately after speculum insertion, tenaculum application and IUD placement; and 5 minutes after the procedure
|
Pain was rated on a 100-mm visual analog scale from 0 (no pain) to 100 (worst imaginable pain). Before the procedure, women rated the pain they expected to feel during insertion (anticipated pain). |
Before the procedure (anticipated pain); immediately after speculum insertion, tenaculum application and IUD placement; and 5 minutes after the procedure
|
|
Pulse rate (beats per minute
大体时间:Before the procedure; immediately after speculum insertion, tenaculum application and IUD placement; and 5 minutes after the procedure
|
Pulse rate was measured by the same researcher with the same device in both groups. |
Before the procedure; immediately after speculum insertion, tenaculum application and IUD placement; and 5 minutes after the procedure
|
|
Respiratory rate (breaths per minute)
大体时间:Before the procedure and 5 minutes after the procedure
|
Respiratory rate was counted by the same researcher in both groups. |
Before the procedure and 5 minutes after the procedure
|
|
Systolic and diastolic blood pressure (mmHg)
大体时间:Before the procedure and 5 minutes after the procedure
|
Blood pressure was measured by the same researcher with the same device in both groups. |
Before the procedure and 5 minutes after the procedure
|
|
Duration of IUD insertion (minutes
大体时间:During the procedure
|
Time from the start to the end of the insertion procedure, recorded by the researcher in whole minutes. |
During the procedure
|
|
Practitioner satisfaction with the procedure
大体时间:Immediately after the procedure
|
The practitioner performing the insertion rated overall satisfaction with the procedure on a single-item 100-mm visual analog scale from 0 (not at all satisfied) to 100 (completely satisfied). |
Immediately after the procedure
|
合作者和调查者
调查人员
- 学习椅:Emine BAŞ, PhD、Sanko University
- 学习椅:Zeynep GÜNGÖRMÜŞ, Prof、Gaziantep Islam Science and Technology University
- 首席研究员:Yasemin ATEŞEYAN, PhD、MERSİN UNIVERSITY
- 学习椅:Esra VERİM, PhD、GAZİANTEP UNIVERSITY
出版物和有用的链接
一般刊物
- Aydın, A., Araz, A., Asan, A. 2011. Görsel Analog Ölçeği ve Duygu Kafesi: Kültürümüze Uyarlama Çalışması, Türk Psikoloji Yazıları,14 (27), 1-13.
- Kolcaba, K. (2003). Comfort Theory and Practice A vision for holistik health care and research, Springer Publishing Company. New York
- Kuğuoğlu, S., & Karabacak, Ü. (2008). Genel Konfor Ölçeğinin Türkçe 'ye uyarlanması. İstanbul Üniversitesi Florence Nightingale Hemşirelik Yüksekokulu Dergisi, 61(16), 16-23.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- SANKO UNIVERSITY
- YASEMİN ATEŞEYAN (注册表标识符:VR-IUD)
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
Data are available from the corresponding author upon reasonable request because of privacy and ethical restrictions.
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.