IBIS - Investigating Reliability of BIS and SEDLINE Monitoring in Children With Developmental and Epileptic Encephalopathies (DEE). (IBIS)
When children have surgery, anaesthetists carefully monitor the depth of anaesthesia by using sensors on the forehead that measure brain activity, also known as processed electroencephalogram (pEEG). These monitors are routinely used in paediatric anaesthesia; however, investigators do not know if they work accurately in babies and young children with seizure disorders or on anti-seizure medications.
Children with developmental and epileptic encephalopathies may need anaesthesia for tests or procedures. It is important that their treating doctors understand whether these monitors truly reflect how awake or asleep the children are. This study aims to compare a child's electrical brain activity using two commonly used devices in paediatric anaesthesia with the conventional 21-lead EEG patterns in children with seizure disorders. The results of this research may help improve the safety and perioperative care of children with seizure disorders who require general anaesthesia in the future.
研究概览
地位
详细说明
There is currently no available data on the reliability of processed electroencephalogram (pEEG) for adequately predicting depth of anaesthesia (DOA) with abnormal electroencephalogram (EEG) and those on anticonvulsant medication. Examples of epilepsy syndromes in which seizures and abnormal EEG (abnormal backgrounds: including excess discontinuity, excess slow, low amplitude, lack of sleep stages, and frequent epileptiform discharges) are predominant features are Early Infantile Developmental and Epileptic Encephalopathy (EIDEE), Epilepsy of infancy with Migrating Focal Seizures (EIMFS), Infantile Spasm Syndrome (IS) and other Epileptic encephalopathies (EE) and Developmental and Epileptic Encephalopathy (DEE). Considering the use of pEEG is common in paediatric anaesthesia and one of the strategies used to precent awareness and excessive anaesthesia provision, it would be pertinent to examine whether pEEG values truly reflect depth of sedation of these infants or if they are artificially low or high. To this end, investigators aim to concurrently measure EEG and pEEG patterns in infants with DEEs with onset in infancy and early childhood. Both pEEG patterns and their values will be measured with two commonly used monitors- the BiSpectral Index (BIS) and Sedline. Data from both pEEG monitors can then be directly compared with contemporaneous conventional EEG patterns on each patient.
This study will be conducted in collaboration with paediatric anaesthetists and neurologists in Perth Children's Hospital, Western Australia and the Hospital das Clínicas, Faculty of Medicine, University of São Paulo, Brazil. The target sample size is 40 participants- 20 from each centre. Participants will be invited to visit the hospital. Each awake participant will be fitted with a 16-lead EEG and additionally a BIS or Sedline monitor, applied consecutively in random order. The measurement period will be 30 minutes for each of the BIS and the Sedline with continuous EEG assessment throughout. This will allow the pEEG data to be measured against a corresponding continuous EEG.
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Britta S von Ungern-Sternberg, MD, PhD
- 电话号码:+61 8 6456 4806
- 邮箱:britta.regli-vonungern@health.wa.gov.au
学习地点
-
-
-
São Paulo、巴西
- Hospital das Clinicas, São Paulo, Sao Paulo
-
接触:
- Vinícius Quintão, MD PHD
- 电话号码:+55 11 2661 5795
- 邮箱:vinicius.quintao@hc.fm.usp.br
-
-
-
-
Western Australia
-
Perth、Western Australia、澳大利亚、6909
- Perth Children's Hospital
-
接触:
- Britta S von Ungern-Sternberg, MD, PhD
- 电话号码:+61 8 6456 4806
- 邮箱:britta.regli-vonungern@health.wa.gov.au
-
接触:
- Lliana Slevin, BSc
- 电话号码:+61 426 952 977
- 邮箱:lliana.slevin@thekids.org.au
-
-
参与标准
资格标准
适合学习的年龄
- 孩子
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Children (<16 years old) with a confirmed diagnosis of early onset EE or DEE due to any cause (prior to age 2 years).
Exclusion Criteria:
- Language barriers impeding data collection
- Department for Child Protection and Family Support is involved in the care of the child.
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Children (<16 years) with confirmed diagnosis of early onset EE or DEE due to any cause
Children (<16 years old) with a confirmed diagnosis of early onset epileptic encephalopathy (EE) or Developmental and epileptic encephalopathy (DEE) due to any cause (prior to age 2 years).
|
This is an observational study of children under 16 years of age, who will be fitted with a 21-lead EEG and then, in consecutive random order, a BIS or Sedline monitor with measurements taken for 30 minutes with each monitor, 60 min in total. This will allow pEEG data to be measured against a corresponding continuous EEG. The depth of anaesthesia monitors used are Bispectral Index (BIS, Medtronic, Minneapolis, Minnesota, USA) and Sedline (Masimo, Irvine, California, USA). |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Compare pEEG values in awake patients with developmental and epileptic encephalopathies
大体时间:60 minutes of monitoring in total - Sedline and BIS monitors will be fitted for 30 minutes each, in consecutive random order.
|
pEEG will be measured using Sedline and BIS monitors alongside standard 21-lead EEG.
|
60 minutes of monitoring in total - Sedline and BIS monitors will be fitted for 30 minutes each, in consecutive random order.
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- RGS0000008394
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.