Predicting Dynamic Inspiratory Muscle Strength in COPD and Asthma Patients (DIMS-PRED)
Prediction Models for Dynamic Respiratory Muscle Strength in COPD and Asthma Patients Based on Constant-Pressure Inspiratory Muscle Performance
This observational study evaluates whether dynamic inspiratory muscle strength can be estimated in patients with chronic obstructive pulmonary disease (COPD) and asthma using simple clinical and performance-based measurements. Dynamic inspiratory muscle strength was assessed using the S-Index, which reflects the pressure generated during a fast and forceful inspiration while airflow is maintained.
The study included adult male patients diagnosed with COPD or asthma. Participants completed respiratory muscle strength assessment, pulmonary function testing, body composition assessment, and a fixed-pressure inspiratory muscle performance test using a threshold loading device set at 30 cmH₂O. The number of inspiratory repetitions performed until task failure and related respiratory variables were recorded.
The main aim of the study was to develop prediction models for estimating S-Index values from accessible measures such as peak inspiratory flow, inspiratory repetition performance, spirometry parameters, and body composition variables. The study may help determine whether dynamic inspiratory muscle strength can be estimated in clinical settings where direct S-Index measurement devices are not available.
研究概览
地位
详细说明
Dynamic inspiratory muscle strength provides important information about the functional capacity of the inspiratory muscles. In patients with chronic respiratory diseases such as COPD and asthma, respiratory muscle function may be affected by airflow limitation, altered ventilatory mechanics, dyspnea, and reduced exercise tolerance. Although maximal inspiratory pressure is commonly used to assess respiratory muscle strength, it mainly reflects static pressure-generating capacity. The S-Index is a dynamic measure obtained during a rapid and forceful inspiratory maneuver and may provide additional information about inspiratory muscle performance under flow-dependent conditions.
This study was designed as an observational, cross-sectional predictive modeling study. Adult male patients with a clinical diagnosis of COPD or asthma were prospectively recruited from clinical units of Çorum Erol Olçok Training and Research Hospital, Hitit University, Türkiye. All participants provided informed consent before participation. The study was approved by the Hitit University Non-Interventional Research Ethics Committee.
Participants attended a familiarization session before the measurement day. During this session, the study procedures were explained, the measurement techniques were demonstrated, and participants were informed about behaviors to avoid before testing. On the measurement day, demographic information was recorded, and participants underwent dynamic inspiratory muscle strength assessment, body composition assessment, pulmonary function testing, and a fixed-pressure inspiratory muscle performance test.
The S-Index was measured using the POWERbreathe K5 device in single-breath test mode. Participants were instructed to exhale fully to residual volume and then perform the fastest and strongest possible inspiration through the device until the lungs were completely filled. Multiple trials were performed, and the highest S-Index value was used for analysis.
Pulmonary function testing was performed using standardized spirometry procedures. Forced vital capacity, forced expiratory volume in one second, the FEV1/FVC ratio, peak expiratory flow, peak inspiratory flow rate, and inspiratory volume were recorded. Body composition variables, including body weight, body mass index, fat-free mass, fat mass, and body fat percentage, were assessed using multi-frequency bioelectrical impedance analysis.
Inspiratory muscle performance was evaluated using a fixed-pressure inspiratory muscle loading task with the POWERbreathe Classic Light Resistance device set at 30 cmH₂O. Participants performed continuous inspiratory efforts through the device until task failure. The total number of valid inspiratory repetitions and the time to task failure were recorded. Task failure was defined as inability to maintain rhythmic breathing, marked reduction in inspiratory effort, technical errors, or voluntary termination due to inability to continue.
Safety was monitored throughout the testing procedures by healthcare professionals and researchers experienced in respiratory physiology and exercise testing. Testing was stopped if clinically relevant symptoms occurred, including severe dyspnea, dizziness, chest pain, wheezing, chest tightness, coughing attacks, or inability to maintain proper technique. No adverse clinical events requiring medical intervention were reported during the study.
The primary purpose of the analysis was to develop statistical and machine learning-based prediction models for estimating S-Index values. Predictor variables included demographic characteristics, body composition variables, spirometry parameters, peak inspiratory flow, inspiratory volume, number of inspiratory repetitions, and time to task failure. Regression-based models were developed and evaluated using standard prediction performance metrics, including mean squared error, mean absolute error, root mean squared error, and the coefficient of determination.
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
-
Çorum、土耳其(türkiye)
- Hitit University Çorum Erol Olçok Training and Research Hospital
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Being 18 years of age or older
- Having a clinical diagnosis of chronic obstructive pulmonary disease or asthma
- Being able to perform fixed-pressure inspiratory muscle loading and S-Index measurements in accordance with the instructions and with correct technique
- Having experienced no additional clinical condition within the previous 12 weeks, apart from the existing chronic respiratory disease, that could acutely affect respiratory function
- Having signed the informed consent form approved by the ethics committee
Exclusion Criteria:
- Smoking
- Inability to perform fixed-pressure inspiratory muscle loading or dynamic respiratory muscle strength assessment according to the technical requirements of the measurement protocols
- Inability to obtain reliable data due to insufficient coordination, motivation, or volitional effort
- Presence of a musculoskeletal injury or surgical history affecting the diaphragm, thorax, spine, or abdominal region that could significantly impair respiratory mechanics
- Presence of neurological conditions that may affect respiratory muscle function, such as neuromuscular diseases, peripheral nerve damage, or central nervous system disorders
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
|---|
|
COPD Patients
Adult male patients with a clinical diagnosis of chronic obstructive pulmonary disease who underwent dynamic inspiratory muscle strength assessment, spirometry, body composition assessment, and fixed-pressure inspiratory muscle performance testing.
|
|
Asthma Patients
Adult male patients with a clinical diagnosis of asthma who underwent dynamic inspiratory muscle strength assessment, spirometry, body composition assessment, and fixed-pressure inspiratory muscle performance testing.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Dynamic Inspiratory Muscle Strength Assessed by S-Index
大体时间:Day 1, during the single assessment visit
|
Dynamic inspiratory muscle strength was assessed using the S-Index measured with the POWERbreathe K5 device in single-breath test mode.
Participants performed maximal and rapid inspiratory efforts after full expiration to residual volume.
The highest S-Index value obtained from repeated maximal inspiratory efforts was recorded in cmH₂O.
|
Day 1, during the single assessment visit
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Number of Inspiratory Repetitions to Task Failure
大体时间:Day 1, during the single assessment visit
|
Inspiratory muscle performance was evaluated using a fixed-pressure inspiratory muscle loading task with the POWERbreathe Classic Light Resistance device set at 30 cmH₂O.
The total number of valid inspiratory repetitions completed until task failure was recorded as a count.
|
Day 1, during the single assessment visit
|
|
Time to Task Failure During Fixed-Pressure Inspiratory Loading
大体时间:Day 1, during the single assessment visit
|
The duration of the fixed-pressure inspiratory muscle loading task was measured using a stopwatch.
Time to task failure was recorded in seconds from the start of the test until the participant could no longer continue with proper technique or voluntarily stopped.
|
Day 1, during the single assessment visit
|
|
Forced Vital Capacity
大体时间:Day 1, during the single assessment visit
|
Forced vital capacity was assessed using standardized spirometry procedures and recorded in liters.
|
Day 1, during the single assessment visit
|
|
Forced Expiratory Volume in One Second
大体时间:Day 1, during the single assessment visit
|
Forced expiratory volume in one second was assessed using standardized spirometry procedures and recorded in liters.
|
Day 1, during the single assessment visit
|
|
FEV1/FVC Ratio
大体时间:Day 1, during the single assessment visit.
|
The ratio of forced expiratory volume in one second to forced vital capacity was calculated from standardized spirometry measurements and recorded as a percentage.
|
Day 1, during the single assessment visit.
|
|
Peak Expiratory Flow
大体时间:Day 1, during the single assessment visit.
|
Peak expiratory flow was obtained from standardized spirometry testing and recorded in liters per second.
|
Day 1, during the single assessment visit.
|
|
Inspiratory Volume
大体时间:Day 1, during the single assessment visit.
|
Inspiratory volume was obtained during pulmonary function testing and recorded in liters.
|
Day 1, during the single assessment visit.
|
|
Secondary Outcome Measure 7
大体时间:Day 1, during the single assessment visit.
|
Peak inspiratory flow rate was obtained from the inspiratory phase of the standardized flow-volume curve and recorded in liters per second.
|
Day 1, during the single assessment visit.
|
合作者和调查者
出版物和有用的链接
一般刊物
- American Thoracic Society/European Respiratory Society. ATS/ERS Statement on respiratory muscle testing. Am J Respir Crit Care Med. 2002 Aug 15;166(4):518-624. doi: 10.1164/rccm.166.4.518. No abstract available.
- Caruso P, Albuquerque AL, Santana PV, Cardenas LZ, Ferreira JG, Prina E, Trevizan PF, Pereira MC, Iamonti V, Pletsch R, Macchione MC, Carvalho CR. Diagnostic methods to assess inspiratory and expiratory muscle strength. J Bras Pneumol. 2015 Mar-Apr;41(2):110-23. doi: 10.1590/S1806-37132015000004474.
- Areias GS, Santiago LR, Teixeira DS, Reis MS. Concurrent Validity of the Static and Dynamic Measures of Inspiratory Muscle Strength: Comparison between Maximal Inspiratory Pressure and S-Index. Braz J Cardiovasc Surg. 2020 Aug 1;35(4):459-464. doi: 10.21470/1678-9741-2019-0269.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- 2026-01 (Hitit University Non-Interventional Research Ethics Committee)
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.