Body Composition, Functional Capacity, and Respiratory Muscle Endurance in Obesity With Restrictive Ventilatory Pattern
2026年5月15日 更新者:Buket AKINCI、Biruni University
Investigation of the Relationship Between Body Composition, Functional Capacity, and Respiratory Muscle Endurance in Individuals With Obesity and a Restrictive Ventilatory Pattern
This observational cross-sectional study aims to examine the relationship between body composition, functional capacity, and respiratory muscle endurance in individuals with obesity and a restrictive ventilatory pattern.
A total of 100 adults aged 25-60 years with a body mass index (BMI) ≥30 kg/m² and restrictive pulmonary function findings will be enrolled.
Participants will evaluate body composition assessment using bioelectrical impedance analysis, pulmonary function testing by spirometry, respiratory muscle strength and endurance measurements, and functional capacity evaluation using the Six-Minute Walk Test (6MWT).
The aim of this study is to evaluate the relationships between stem cell count (SCC), a novel anthropometric indicator called WWI, trunk muscle mass, and functional capacity in obese individuals with a restrictive ventilatory pattern.
研究概览
研究类型
观察性的
注册 (估计的)
100
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习联系方式
- 姓名:Buket Akinci, Prof. Dr.
- 电话号码:+90 505 6415692
- 邮箱:bakinci@biruni.edu.tr
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
- 成人
接受健康志愿者
是的
取样方法
非概率样本
研究人群
Obese Individuals with Restrictive Ventilatory Pattern
描述
Inclusion Criteria:
- Individuals aged between 25 and 60 years
- Individuals with a body mass index (BMI) ≥ 30 kg/m² according to the World Health Organization (WHO) classification
- Individuals demonstrating a restrictive ventilatory pattern (FVC < 80% predicted)
- Individuals who voluntarily agree to participate in the study
Exclusion Criteria:
- Individuals with a Charlson Comorbidity Index (CCI) score of 3 or higher
- Individuals with uncontrolled arrhythmia, hypertension, heart failure, diabetes mellitus, or unstable angina pectoris
- Individuals with cooperation impairments, orthopedic, or neurological conditions that may interfere with assessment or treatment
- Individuals with a history of lower extremity injury or surgery within the last six months
- Individuals diagnosed with diabetes mellitus who have complications such as nephropathy, retinopathy, or neuropathy
- Individuals with concomitant chronic respiratory disease
- Individuals with acute infection
- Individuals with middle ear pathologies (e.g., tympanic membrane rupture or otitis)
- Individuals with a history of spontaneous or trauma-related pneumothorax
- Current smokers
- Pregnant individuals
- Individuals with a STOP-Bang score of 3 or higher
- Individuals currently participating in a structured weight-loss diet program or receiving medical treatment for weight loss during the assessment period
- Individuals who have undergone endoscopic intervention and/or bariatric surgery within the last year
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Obese Individuals with Restrictive Ventilatory Pattern
|
Participants will undergo a comprehensive assessment including pulmonary function testing using spirometry, body composition analysis using bioelectrical impedance analysis (BIA), respiratory muscle strength and endurance evaluation, and functional capacity assessment with the Six-Minute Walk Test (6MWT).
Anthropometric measurements including body weight, height, waist circumference, hip circumference, and waist-to-height ratio will also be recorded.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Functional capacity
大体时间:Day 1
|
Participants' exercise capacity will be assessed using the Six-Minute Walk Test (6MWT) according to the American Thoracic Society (ATS) guidelines with the Spiropalm 6MWT system (Cosmed, Italy) (ATS, 2002).
The test will be performed in a 30-meter indoor corridor following a minimum 10-minute rest period.
Heart rate, blood pressure, oxygen saturation, dyspnea, and leg fatigue levels will be recorded before and after the test.
Participants will be instructed to walk as fast as possible for six minutes and may rest or terminate the test if severe symptoms occur.
Total walking distance will be recorded in meters, and any interruptions or symptoms during the test will be documented.
|
Day 1
|
|
Respiratory Muscle Endurance
大体时间:Day 1
|
Participants' respiratory muscle endurance will be assessed using an inspiratory muscle training device (POWERbreathe® K-Series K3, POWERbreathe International Ltd, UK).
Measurements will be performed in a seated position with a nose clip applied and the device placed in the mouth.
The assessment will be conducted using an incremental threshold loading protocol.
At the beginning of the test, the threshold pressure will be set at 20% of the participant's maximal inspiratory pressure (MIP).
Participants will be instructed to complete 30 breaths over a two-minute period.
Individuals who tolerate this level will progress to subsequent stages with gradually increasing loads of 40%, 60%, 80%, and 100% of MIP, respectively.
Oxygen saturation and heart rate will be recorded before and after the test using a pulse oximeter.
Participants will also be informed that they may remove the device from their mouth and terminate the test at any time in the event of any discomfort or adverse symptoms.
|
Day 1
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Body fat mass
大体时间:Day 1
|
Participants' body fat mass (kg) will be measured using Bioelectrical Impedance Analysis (BIA).
Participants will be informed about the test protocol and instructed to fast for 8-12 hours before the assessment, arrive with an empty bladder, and avoid fluid intake, food consumption, and vigorous physical activity prior to testing.
Measurements will be performed during daytime at a room temperature of 25°C.
Participants will be assessed while clothed and barefoot after removing their shoes, socks, and all metal accessories.
|
Day 1
|
|
Forced vital capacity (FVC)
大体时间:Day 1
|
Forced vital capacity (FVC) will be evaluated using a Pulmonary Function Test (PFT) in accordance with the American Thoracic Society (ATS) and European Respiratory Society (ERS) criteria, utilizing the "COSMED Spiropalm 6MWT" device (COSMED, Italy) and its integrated PFT software (ATS & ERS, 2002).
Assessments will be performed in a seated position with back support.
To minimize the risk of infection, a disposable mouthpiece and filter will be used for each participant.
Values will be recorded both in liters and as percentages (%) of predicted values.
Measurements will be repeated three times, and the best value meeting the measurement standards will be recorded.
|
Day 1
|
|
Ventilation (VE)
大体时间:Day 1
|
Ventilation (VE) will be measured during the Six-Minute Walk Test (6MWT) using the Spiropalm device.
|
Day 1
|
|
Body muscle mass
大体时间:Day 1
|
Body muscle mass (kg) will be measured using Bioelectrical Impedance Analysis (BIA).
Participants will be informed about the test protocol and instructed to fast for 8-12 hours before the assessment, arrive with an empty bladder, and avoid fluid intake, food consumption, and vigorous physical activity prior to testing.
Measurements will be performed during daytime at a room temperature of 25°C.
Participants will be assessed while clothed and barefoot after removing their shoes, socks, and all metal accessories.
|
Day 1
|
|
Forced expiratory volume in the first second (FEV1)
大体时间:Day 1
|
Forced expiratory volume in the first second (FEV1) will be evaluated using a Pulmonary Function Test (PFT) in accordance with the American Thoracic Society (ATS) and European Respiratory Society (ERS) criteria, utilizing the "COSMED Spiropalm 6MWT" device (COSMED, Italy) and its integrated PFT software (ATS & ERS, 2002).
Assessments will be performed in a seated position with back support.
To minimize the risk of infection, a disposable mouthpiece and filter will be used for each participant.
Values will be recorded both in liters and as percentages (%) of predicted values.
Measurements will be repeated three times, and the best value meeting the measurement standards will be recorded.
|
Day 1
|
|
FEV1/FVC ratio
大体时间:Day 1
|
FEV1/FVC ratio will be evaluated using a Pulmonary Function Test (PFT) in accordance with the American Thoracic Society (ATS) and European Respiratory Society (ERS) criteria, utilizing the "COSMED Spiropalm 6MWT" device (COSMED, Italy) and its integrated PFT software (ATS & ERS, 2002).
Assessments will be performed in a seated position with back support.
To minimize the risk of infection, a disposable mouthpiece and filter will be used for each participant.
Values will be recorded both in liters and as percentages (%) of predicted values.
Measurements will be repeated three times, and the best value meeting the measurement standards will be recorded
|
Day 1
|
|
Peak ventilation (VEpeak)
大体时间:Day 1
|
Peak ventilation (VEpeak) will be measured during the Six-Minute Walk Test (6MWT) using the Spiropalm device.
|
Day 1
|
|
Peak breathing reserve (BRpeak)
大体时间:Day 1
|
Peak breathing reserve (BRpeak) will be measured during the Six-Minute Walk Test (6MWT) using the Spiropalm device.
|
Day 1
|
|
Respiratory frequency (RF)
大体时间:Day 1
|
Respiratory frequency (RF) will be measured during the Six-Minute Walk Test (6MWT) using the Spiropalm device.
|
Day 1
|
|
Inspiratory capacity (IC)
大体时间:Day 1
|
Inspiratory capacity (IC) will be measured during the Six-Minute Walk Test (6MWT) using the Spiropalm device.
|
Day 1
|
|
Body muscle percentage
大体时间:Day 1
|
Body muscle percentage (%) will be measured using Bioelectrical Impedance Analysis (BIA).
Participants will be informed about the test protocol and instructed to fast for 8-12 hours before the assessment, arrive with an empty bladder, and avoid fluid intake, food consumption, and vigorous physical activity prior to testing.
Measurements will be performed during daytime at a room temperature of 25°C.
Participants will be assessed while clothed and barefoot after removing their shoes, socks, and all metal accessories.
|
Day 1
|
|
Weight-Adjusted Waist Index (WWI)
大体时间:Day 1
|
Weight-Adjusted Waist Index (WWI) will be calculated by dividing waist circumference (cm) by the square root of body weight (kg).
|
Day 1
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始 (估计的)
2026年6月30日
初级完成 (估计的)
2026年11月20日
研究完成 (估计的)
2026年12月15日
研究注册日期
首次提交
2026年5月8日
首先提交符合 QC 标准的
2026年5月15日
首次发布 (实际的)
2026年5月22日
研究记录更新
最后更新发布 (实际的)
2026年5月22日
上次提交的符合 QC 标准的更新
2026年5月15日
最后验证
2026年5月1日
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.