Evaluating the Efficacy and Safety of Octane Aether for Treating Chronic Low Back Pain
A Randomized, Double-blind, Sham-controlled Study to Evaluate the Efficacy and Safety of the Octane [Aether] Bioelectricity Device for the Management of Chronic Low Back Pain
The goal of this clinical trial is to evaluate the safety of the Octane Aether device and to determine whether the device is effective in treating symptoms of non-specific chronic low back pain in adults. The Octane Aether is a wearable device that produces specific magnetic field outputs and is designed for daily use in a home setting. The main objectives of the trial are:
- To measure the change in patient-reported pain scores during active treatment with the device compared to a sham treatment, and
- To define and describe the adverse effects, if any, of the Octane Aether device when administered according to the protocol.
Every participant will evaluate three active output modes and a sham output using the same device. Patient-reported outcomes will inform the effectiveness of each output mode and help identify the need for personalization in magnetic field therapy.
Participants will:
- Use the device at home for 60 minutes every day for 10 weeks,
- Report daily pain scores using an electronic visual analog scale for pain intensity,
- Visit the clinic 5 times over the course of the 13 week trial for checkups and device changes,
- Respond to 3 phone calls for checkups, and
- Fill various questionnaires related to disability, quality of life, and their back pain.
研究概览
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Ontario
-
Kingston、Ontario、加拿大、K7K 0J7
- Kingston Orthopaedic Pain Institute
-
接触:
- Thomas Gregory
- 电话号码:613-507-7246
- 邮箱:thomas.gregory@queensu.ca
-
首席研究员:
- Thomas Gregory
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Able to provide informed consent;
- Aged 18-65;
- Pain intensity of at least 5 on a numerical rating scale (0-10);
- Experiencing chronic low back pain that has persisted for ≥3 months;
- Pain localized primarily to the lumbar spine region;
- Conservative treatments, such as physical therapy, NSAIDs and lifestyle changes, have failed over the past 6 months. Participants are allowed to continue conservative treatments, but changes to use/frequency will be tracked; and
- Must be able to attend 5 in-person clinic appointments over the 13-week study period.
Exclusion Criteria:
- Began using new prescription medication for pain within the past 3 months;
- Lumbar spine surgery (within the past 12 months);
- Body Mass Index (BMI)> 35. The device may have diminished effectiveness and/or may not fit individuals with high BMI;
- Presence of a cardiac pacemaker;
- Pregnancy or breastfeeding;
- Presence of ferromagnetic implants or body piercings (e.g., navel piercings) in the lumbar region, including hip implants/replacements or similar in the pelvic region, that could interfere with device function;
- Inability to put on, adjust, and/or operate the wearable device without assistance;
- Prior use of PEMF, or other electromagnetic field-emitting device, for the treatment of pain symptoms;
- No, or inconsistent, access to internet (emailed surveys are used for daily data collection); and
- Any condition or diagnosis that could in the opinion of the Principal Investigator or delegate interfere with the participant's ability to comply with study instructions, might confound the interpretation of the study results, or put the participant at risk.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:四人间
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Sequence Group 1
Participants receive active/sham treatments in the following sequence: EMF A, EMF B, Sham, EMF C
|
The Octane Aether is a body-worn device that generates pulsed magnetic fields of specific characteristics designed to target cellular behaviour in relation to chronic pain signalling. The device features four different output modes (3 active and 1 sham) to enable an investigation of the need for personalized pain management. The specific characteristics of the output modes are blinded from the participants and study team and are labelled here as EMF A, EMF B, EMF C, and Sham. The device firmware is programmed to automatically change the output mode every two weeks. The device produces no sound or thermal effects. When operating in the sham mode, the device appears identical to active output, but no current is applied to the body-worn coil applicator and no magnetic field is generated.
其他名称:
|
|
实验性的:Sequence Group 2
Participants receive active/sham treatments in the following sequence: EMF B, EMF C, EMF A, Sham
|
The Octane Aether is a body-worn device that generates pulsed magnetic fields of specific characteristics designed to target cellular behaviour in relation to chronic pain signalling. The device features four different output modes (3 active and 1 sham) to enable an investigation of the need for personalized pain management. The specific characteristics of the output modes are blinded from the participants and study team and are labelled here as EMF A, EMF B, EMF C, and Sham. The device firmware is programmed to automatically change the output mode every two weeks. The device produces no sound or thermal effects. When operating in the sham mode, the device appears identical to active output, but no current is applied to the body-worn coil applicator and no magnetic field is generated.
其他名称:
|
|
实验性的:Sequence Group 3
Participants receive active/sham treatments in the following sequence: EMF C, Sham, EMF B, EMF A
|
The Octane Aether is a body-worn device that generates pulsed magnetic fields of specific characteristics designed to target cellular behaviour in relation to chronic pain signalling. The device features four different output modes (3 active and 1 sham) to enable an investigation of the need for personalized pain management. The specific characteristics of the output modes are blinded from the participants and study team and are labelled here as EMF A, EMF B, EMF C, and Sham. The device firmware is programmed to automatically change the output mode every two weeks. The device produces no sound or thermal effects. When operating in the sham mode, the device appears identical to active output, but no current is applied to the body-worn coil applicator and no magnetic field is generated.
其他名称:
|
|
实验性的:Sequence Group 4
Participants receive active/sham treatments in the following sequence: Sham, EMF A, EMF C, EMF B
|
The Octane Aether is a body-worn device that generates pulsed magnetic fields of specific characteristics designed to target cellular behaviour in relation to chronic pain signalling. The device features four different output modes (3 active and 1 sham) to enable an investigation of the need for personalized pain management. The specific characteristics of the output modes are blinded from the participants and study team and are labelled here as EMF A, EMF B, EMF C, and Sham. The device firmware is programmed to automatically change the output mode every two weeks. The device produces no sound or thermal effects. When operating in the sham mode, the device appears identical to active output, but no current is applied to the body-worn coil applicator and no magnetic field is generated.
其他名称:
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Change in patient-reported pain scores during active treatment compared to the sham treatment period
大体时间:From start of Treatment Period 1 (Week 2) to end of Treatment Period 4 (Week 9)
|
The difference in the mean pain VAS of scores reported in the second week of each active treatment period and the mean VAS of the second week of the same participant's sham period.
|
From start of Treatment Period 1 (Week 2) to end of Treatment Period 4 (Week 9)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Adverse effects associated with the use of the Octane Aether
大体时间:From start of device use (Week 2) to follow-up appointment (Week 13 - end of study)
|
To define and describe the adverse effects of the Octane Aether when administered according to the clinical trial protocol.
Participants and the study team will report adverse events associated with use of the device or device malfunctions.
|
From start of device use (Week 2) to follow-up appointment (Week 13 - end of study)
|
|
Effect of treatment on quality of life and disability index
大体时间:From end of first treatment period (Week 3) to end of fourth treatment period (Week 9)
|
The Octane Aether's effect is evaluated using the Roland-Morris Disability questionnaire, which assesses low back pain's influence on disability and quality of life.
The questionnaire is completed after each active and sham treatment period and compared.
|
From end of first treatment period (Week 3) to end of fourth treatment period (Week 9)
|
|
Net change in perceived pain intensity (start to end)
大体时间:From baseline week (pre-intervention) to end of Treatment Period 4 (Week 9)
|
The change in mean pain VAS scores from the baseline week to the final week of Treatment Period 4 (Week 9).
|
From baseline week (pre-intervention) to end of Treatment Period 4 (Week 9)
|
|
Net effect of intervention on disability index
大体时间:From baseline (Week 1) to end of Treatment Period 4 (Week 9)
|
Change in Roland-Morris Disability questionnaire responses from Baseline to end of Treatment Period 4.
|
From baseline (Week 1) to end of Treatment Period 4 (Week 9)
|
|
Effect of Octane Aether EMF treatment on general health (physical and emotional)
大体时间:From Week 1 to Week 9
|
Participants respond to the RAND 36-item health survey after Week 1 and Week 9 and the change in category scores associated with physical and emotional health and quality of life are analyzed.
|
From Week 1 to Week 9
|
|
Longevity of the effect of Octane Aether treatment
大体时间:From end of device use (Week 11) to follow-up appointment (Week 13)
|
VAS for pain reports are used to assess changes in pain intensity two weeks after the end of intervention use to evaluate whether there is a lasting effect from the treatment.
|
From end of device use (Week 11) to follow-up appointment (Week 13)
|
|
Longevity of the intervention effect on disability and quality of life
大体时间:From end of device use (Week 11) to follow-up appointment (Week 13)
|
Roland-Morris Disability Questionnaire responses are used to evaluate the potential lasting effect of the interventional device after stopping daily use.
|
From end of device use (Week 11) to follow-up appointment (Week 13)
|
其他结果措施
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Effectiveness of EMF A vs B vs C
大体时间:From Treatment Period 1 (Week 2) to 4 (Week 9)
|
Compare the change in pain VAS scores reported from start to finish of each active and sham output mode.
|
From Treatment Period 1 (Week 2) to 4 (Week 9)
|
|
Output mode preference
大体时间:Treatment Period 5 (Week 10)
|
Tally of output mode that each participant chose to repeat during Treatment Period 5. Participants are asked to select their preferred mode.
|
Treatment Period 5 (Week 10)
|
|
Changes in medication use
大体时间:Responses recorded at Baseline and all scheduled appointments (after Week 1, 3, 5, 7, 9, 11, and 13)
|
To assess whether the use of the interventional device affects how participants report using (non-prescription) medication (dosage and frequency).
|
Responses recorded at Baseline and all scheduled appointments (after Week 1, 3, 5, 7, 9, 11, and 13)
|
|
Device performance - Temperature
大体时间:Measurement data exported from the device after the device is returned during the Week 11 appointment.
|
Device performance is assessed by analyzing coil temperature sensor measurements recorded whenever the device is in use.
Temperature data is compared to calibration measurements.
|
Measurement data exported from the device after the device is returned during the Week 11 appointment.
|
|
Device performance - Magnetic Flux Density
大体时间:Measurement data exported from the device after the device is returned during the Week 11 appointment.
|
Device performance is assessed by analyzing magnetic flux density measurements collected using a Hall-effect sensor embedded in the coil applicator.
Magnetic flux density data recorded during each treatment session is compared to calibration measurements as a measure of performance and consistency.
|
Measurement data exported from the device after the device is returned during the Week 11 appointment.
|
|
Device performance - Current
大体时间:Measurement data exported from the device after the device is returned during the Week 11 appointment.
|
Device performance is assessed by analyzing data received from a current sensor that measures the current through the coil applicator.
Current measurements, recorded during each treatment session, are compared to calibration data at the end of the study.
|
Measurement data exported from the device after the device is returned during the Week 11 appointment.
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- Bioelectricity_FP01
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
在美国制造并从美国出口的产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.