The Purpose of This Clinical Trial is to Evaluate the Accuracy of Blood Pressure Measurement of HiCardi M350 Compared to Blood Pressure Measured by Auscultatory Sphygmomanometer in Adult Volunteers (Including Those Meeting Blood Pressure Distribution Requirements) in Accordance With ISO 81060-2:2018
A Prospective, Single-center, Single-arm, Pivotal Clinical Trial to Evaluate the Accuracy of Blood Pressure Measurements From the HiCardi M350(Patient Monitor) in Comparison With Those Measured Using an Auscultatory Sphygmomanometer
This prospective, single-center, single-arm pivotal clinical trial is designed to evaluate the accuracy of blood pressure measurements obtained using the HiCardi M350 patient monitor compared with measurements obtained using an auscultatory sphygmomanometer.
The study will enroll adult volunteers aged 19 years or older, including participants needed to satisfy the blood pressure distribution requirements of ISO 81060-2:2018. The planned enrollment is 100 participants, considering the ISO 81060-2:2018 minimum requirement of 85 participants and an estimated dropout rate of approximately 15%. The study is also designed to obtain at least 255 valid paired blood pressure values.
After written informed consent, participants will undergo screening assessments, including demographics, vital signs, medical and surgical history, prior and concomitant medications, pregnancy testing for women of childbearing potential, bilateral arm circumference measurement, eligibility assessment, and adverse event assessment. On the blood pressure test day, eligibility will be reconfirmed, an enrollment number will be assigned, HiCardi M350 calibration will be performed, and blood pressure measurements will be obtained using both HiCardi M350 and the reference auscultatory method.
The primary effectiveness endpoint is the difference between systolic and diastolic blood pressure values measured by HiCardi M350 and the reference sphygmomanometer under resting conditions. Accuracy will be evaluated according to ISO 81060-2:2018 using Criteria 1 and Criteria 2. Safety will be evaluated based on adverse events, adverse device effects, serious adverse events, serious adverse device effects, unanticipated adverse device effects, and device deficiencies.
研究概览
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Min Dong Sung, Professor
- 电话号码:+82-10-6554-0827
- 邮箱:MDSUNG@yuhs.ac
学习地点
-
-
Seoul
-
Seoul、Seoul、韩国、03722
- 招聘中
- Severance Hospital
-
接触:
- Min Dong Sung, Professor
- 电话号码:+82-10-6554-0827
- 邮箱:MDSUNG@yuhs.ac
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Adults aged 19 years or older.
- Individuals who visit Severance Hospital and voluntarily provide written informed consent after receiving and understanding sufficient explanation of the study.
- Individuals with hypertension-range blood pressure may be included to meet the blood pressure distribution requirements. Participants receiving antihypertensive medication may be included only if the type and dose of medication have remained stable for at least 4 weeks before screening. Individuals with dose changes, medication additions, or medication discontinuation within 4 weeks before screening will be excluded.
Exclusion Criteria:
- Individuals in whom Korotkoff phase V cannot be clearly identified during auscultatory blood pressure measurement.
- Individuals for whom blood pressure measurement is difficult or expected to be difficult.
- Individuals with bilateral arm circumference greater than 42 cm.
- Pregnant women.
- Individuals currently participating in another clinical trial or who have participated in another clinical trial within 30 days before the screening date.
- Individuals judged by the investigator to be inappropriate for participation in the clinical trial.
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:HiCardi M350
Participants will undergo blood pressure measurement using the investigational device, HiCardi M350, and the reference auscultatory sphygmomanometer.
HiCardi M350 will be attached and calibrated according to the predefined procedure.
Systolic and diastolic blood pressure values measured by HiCardi M350 will be compared with reference values measured by two independent observers using the auscultatory method.
|
HiCardi M350 is a wearable patient monitoring device used to measure systolic and diastolic blood pressure.
In this study, the device will be attached to each participant and calibrated according to the predefined procedure.
Blood pressure values measured by HiCardi M350 will be compared with reference values obtained using an auscultatory sphygmomanometer and mechanical stethoscope by two independent observers.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Difference between systolic and diastolic blood pressure measurements obtained using HiCardi M350 and a reference auscultatory sphygmomanometer
大体时间:After completion of all participants' data collection (within approximately 7 months of enrollment period)
|
The primary outcome is the difference between systolic and diastolic blood pressure values measured by HiCardi M350 and the reference auscultatory sphygmomanometer under resting conditions.
Accuracy will be assessed separately for systolic and diastolic blood pressure according to ISO 81060-2:2018 Criteria 1 and Criteria 2.
|
After completion of all participants' data collection (within approximately 7 months of enrollment period)
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- 1-2026-0008
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.