The Use of Immersive Virtual Reality as a Method of Treating Anxiety and Procedural Pain During Endovenous Laser Ablation (EVLA) of Lower Varicose Veins Under Tumescent Anesthesia (EVLA+VR)
研究概览
详细说明
This prospective single-arm interventional study with a pre-post design aims to assess the effect of immersive virtual reality (VR) on procedural anxiety, pain perception, cybersickness, sense of presence, usability, and overall patient satisfaction during ambulatory endovenous laser ablation (EVLA) performed under tumescent local anesthesia (TLA).
All consenting adult patients scheduled for unilateral or bilateral EVLA of the great saphenous vein (GSV), small saphenous vein (SSV), or accessory veins due to symptomatic chronic venous insufficiency (CEAP C2-C6) will be enrolled. There is no control group: every participant who provides informed consent will receive immersive VR (using a head-mounted display with relaxing/immersive nature-based content) starting 5-10 minutes before tumescent infiltration and continuing throughout the procedure (~30-60 minutes).
Key outcome measures will be collected at multiple time points:
Baseline (pre-procedure): hemodynamic parameters, saturation, technology experience, baseline anxiety and pain (VAS / NRS), every 5 minutes during the procedure and right after the surgical procedure, cybersickness (SSQ), satisfaction and any adverse events.
Technology-Focused Objective
• To evaluate usability and tolerability of VR technology in a real clinical setting, including:
- comfort of use during a medical procedure
- interaction with the device during limited mobility
- feasibility of VR integration into procedural workflow
Follow-up (4-6 weeks): delayed pain, satisfaction, technology experience, and adverse events.
The primary endpoint is the change in procedural anxiety (VAS) from pre- to post-procedure. Secondary endpoints include change in pain (NRS) and hemodynamic profile, cybersickness severity, presence scores, usability, patient satisfaction, and safety profile of VR in this setting.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Bydgoszcz、波兰、85-796
- Bydgoszcz Univ of Science and Technology
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- adults people scheduled to EVLA under local anesthesia and signed for VR interventiion.
Exclusion Criteria:
- exclusion of epilepsy, severe motion sickness, previous severe cybersickness
学习计划
研究是如何设计的?
设计细节
- 主要用途:支持治疗
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Adult patients, scheduled to EVLA procedure under local anesthesia.
exclusion of epilepsy, severe motion sickness, previous severe cybersickness
|
Immersive Virtual reality
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Procedural anxiety
大体时间:Baseline (0), at the beginning of surgical procedure (1), at the end of surgical procedure (2) to the end of treatment at 8 weeks (3).
|
Visual Analogue Scale (VAS), 0-10 points, 0-no anxiety, 10-max anxiety level.
Higher scores mean worse outcome.
|
Baseline (0), at the beginning of surgical procedure (1), at the end of surgical procedure (2) to the end of treatment at 8 weeks (3).
|
|
Level of procedural pain
大体时间:Baseline (0), at the beginning of surgical procedure (1), at the end of surgical procedure (2).
|
Visual Analogue Scale (VAS), 0-10, 0- no pain, 10-max pain ever.
Higher scores mean a worse outcome.
|
Baseline (0), at the beginning of surgical procedure (1), at the end of surgical procedure (2).
|
|
Heart Rate
大体时间:Baseline, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
Heart Rate is the number of times a heart beats in one minute (bpm).
Normal heart rate is 60-100 bpm.
|
Baseline, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
|
Cybersickness severity
大体时间:Day 1- after completing the surgical procedure.
|
SSQ The Simulator Sickness Questionnaire is the standard tool used to measure cybersickness. Patients rate 16 symptoms on a scale from 0 to 3- no, moderate, severe. These scores are mathematically weighted and aggreagated into a total scowe ranges 0-48 points. 0-5 severity level negligible, no symptoms, the VR experience is perfectly comfortable. 5-10 severity evel minimal, mild discomfort 10-15 significant, definitive sensory mismatch, patients may experiance slight nausea or disorientation 15-20 concerning, noticeable sickness, the experiance is moderately uncomfortable more than 20- high, the VR application causes severe discomfort and requires a redesign to reduce visual motion. Higher scores mean a worse outcome. The 16 symptoms are mapped into 3 subscales: nausea or stomach awareness, occulomotor- eye strain and difficulty focusing, disorientation- dizziness, vertigo, |
Day 1- after completing the surgical procedure.
|
|
Patient satisfaction
大体时间:From enrollment to the end of treatment at 8 weeks"
|
SUS- usability questionnaire is the system usability scale, which measures the feeling of usability of the users when using computer systems, navigate patient portals, telemedicine platforms, or self-management apps. A reliable tool that measures how easy to use, complex, or efficient a patient or user finds a digital health application. It is composed of 10 questions with a five-point Likert attitude scale (from strongly disagree to strongly agree), typically ranging from 1 ("Not at all") to 5 ("Very much"). Calculation: Scores range from 0 to 100. A score above 68 is generally considered above-average usability. |
From enrollment to the end of treatment at 8 weeks"
|
|
Systolic blood pressure
大体时间:From enrollment, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
Systolic blood pressure measures the maximum pressure of blood exerts against your artery walls when your heart beats and pumps blood out to the body. Key Ranges (in mm Hg) Normal: Below 120, Elevated: 120-129, Hypertension (High Blood Pressure): 130 or higher. |
From enrollment, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
|
Diastolic blood pressure
大体时间:From enrollment, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
Diastolic blood pressure is the bottom (lower) number in a blood pressure reading.
It measures the minimum pressure exerted against artery walls when a heart muscle is resting and refilling with blood between beats.
A standard blood pressure reading is measured in millimeters of mercury (mm Hg).
According to standard cardiovascular guidelines, blood pressure is categorized by the following diastolic ranges:Normal: Less than \(80\) mm Hg.Elevated: Less than \(80\) mm Hg (with systolic between \(120-129\)).Hypertension Stage 1: \(80-89\) mm Hg.Hypertension Stage 2: \(90\) mm Hg or higher.Hypertensive Crisis: Higher than \(120\) mm Hg.
|
From enrollment, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
|
Oxygen saturation
大体时间:From enrollment, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
Oxygen saturation measured by Pulse Oximetry Sp02 measures the percentage of hemoglobin in red blood cells that is actively carrying oxygen.
It indicates how effectively is blood transports oxygen from the lungs throughout the body.Typical Ranges & Interpretation Normal Range: 95% to 100% for a healthy adult.
Low (Hypoxemia): Values below 90% are considered low and typically require external oxygen supplementation or medical evaluation.
|
From enrollment, at the beginning of surgical procedure and every 5 minutes during EVLA and in the end of surgical procedure.
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.