Machine Learning Prediction of Respiratory Muscle Changes and Ventilatory Responses After Incretin-Based Therapy in Obesity
Prediction of Changes in Pulmonary Function, Respiratory Muscle Performance, and Ventilatory Responses Following Incretin-Based Therapy in Individuals With Obesity Using Machine Learning
研究概览
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Şafak Yiğit, PhD
- 电话号码:+90 5309634910
- 邮箱:safakyigit90@gmail.com
参与标准
资格标准
适合学习的年龄
- 成人
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Individuals aged 25-60 years
- Individuals with a body mass index (BMI) ≥ 30 kg/m² according to the World - Health Organization (WHO) classification of obesity
- Individuals who voluntarily agree to participate in the study
Exclusion Criteria:
Charlson Comorbidity Index (CCI) score ≥ 3 Uncontrolled arrhythmia, hypertension, heart failure, diabetes mellitus, or unstable angina pectoris Cognitive, orthopedic, or neurological conditions that may interfere with study assessments or treatment procedures History of lower extremity injury or surgery within the previous 6 months Diagnosis of diabetes mellitus with complications such as nephropathy, retinopathy, or neuropathy Presence of chronic respiratory disease Acute infection at the time of assessment Middle ear pathologies (e.g., tympanic membrane rupture or otitis) History of spontaneous or traumatic pneumothorax Current smoking Pregnancy STOP-Bang score ≥ 3 Participation in a structured weight-loss diet program or receipt of medical treatment for weight reduction during the assessment period History of endoscopic weight-loss procedures and/or bariatric surgery within the previous 12 months
学习计划
研究是如何设计的?
设计细节
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Maximum Inspiratory Pressure (MIP)
大体时间:Baseline to 3 months
|
Maximum inspiratory pressure (MIP) assessment will be performed using an intraoral pressure measuring device (MicroRPM, Micro Medical; UK) in accordance with ATS and ERS criteria.
Measurements will be taken with a nasal clip in place and in a seated position.
To prevent the risk of infection, a disposable mouthpiece and filter will be used for each participant.
For maximum inspiratory pressure (MIP) measurement, maximal inspiration will be applied orally for a few seconds and the values will be recorded.
Measurements will be repeated three times, and the best value that meets the measurement standard will be recorded in cmH2O.
For the measurement to be considered valid, the difference between the two highest measurements must be less than 10%.
When evaluating inspiratory muscle strength, age and gender-specific reference ranges will be considered.
The reference equations developed by Black and Hyatt will be used in the interpretation of the measurements.
|
Baseline to 3 months
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Maximum Expiratory Pressure (MEP)
大体时间:Baseline to 3 months
|
Maximum expiratory pressure (MEP) will be measured using an intraoral pressure measuring device (MicroRPM, Micro Medical; UK) in accordance with ATS and ERS criteria.
Measurements will be performed with a nasal clip in place and in a seated position.
To prevent the risk of infection, a disposable mouthpiece and filter will be used for each participant.
Maximum expiratory pressure (MEP) will be measured by applying maximal exhalation for a few seconds and recording the values.
Measurements will be repeated three times, and the best value that meets the measurement standard will be recorded in cmH2O.
For the measurement to be considered valid, the difference between the two highest measurements must be less than 10%.
When evaluating respiratory muscle strength, age and gender-specific reference ranges will be considered.
Reference equations developed by Black and Hyatt will be used to interpret the measurements.
|
Baseline to 3 months
|
|
Forced vital capacity (FVC)
大体时间:Baseline to 3 months
|
Forced vital capacity (FVC) will be assessed using pulmonary function tests (PFTs).
The assessment will be performed using the "COSMED Spiropalm 6MWT" (COSMED; Italy) device and integrated PFT software, in accordance with ATS and European Respiratory Society (ERS) criteria (ATS&ERS, 2002).
The assessment will be conducted in a seated position with back support.
To prevent the risk of infection, a disposable mouthpiece and filter will be used for each participant.
Values will be recorded in liters and as a percentage (%) of the expected value.
Measurements will be repeated three times, and the best value meeting the measurement standard will be recorded.
|
Baseline to 3 months
|
|
Forced expiratory volume in the first second (FEV1)
大体时间:Baseline to 3 months
|
Forced expiratory volume in the first second (FEV1) will be assessed using pulmonary function tests (PFTs).
The assessment will be performed using the "COSMED Spiropalm 6MWT" (COSMED; Italy) device and integrated PFT software, in accordance with ATS and European Respiratory Society (ERS) criteria (ATS&ERS, 2002).
The assessment will be conducted in a seated position with back support.
To prevent the risk of infection, a disposable mouthpiece and filter will be used for each participant.
Values will be recorded in liters and as a percentage (%) of the expected value.
Measurements will be repeated three times, and the best value meeting the measurement standard will be recorded.
|
Baseline to 3 months
|
|
FEV1/FVC
大体时间:Baseline to 3 months
|
FEV1/FVC will be assessed using pulmonary function tests (PFTs), and the assessment will be performed according to ATS and European Respiratory Society (ERS) criteria using the "COSMED Spiropalm 6MWT" (COSMED; Italy) device and integrated PFT software (ATS&ERS, 2002).
The assessment will be performed in a seated position with back support.
To prevent the risk of infection, a disposable mouthpiece and filter will be used for each participant.
The values will be recorded in liters and as a percentage (%) of the expected value.
Measurements will be repeated three times, and the best value that meets the measurement standard will be recorded.
|
Baseline to 3 months
|
|
Respiratory Muscle Endurance
大体时间:Baseline to 3 months
|
Participants' respiratory muscle endurance will be assessed using an inspiratory muscle training device (POWERbreathe® K-SerieS-K3, POWERbreathe International Ltd, UK).
Measurements will be taken in a seated position with the device placed in the mouth using a nose clip.
The assessment will be conducted using an increasing threshold loading protocol.
At the start of the test, the threshold pressure will be set to 20% of the individual's MIP (maximum inspiratory pressure).
The individual will be asked to breathe 30 times over two minutes.
Individuals who tolerate this level will proceed to the next step, gradually increasing the pressure to 40%, 60%, 80%, and 100% respectively.
Oxygen saturation and pulse rate will be recorded before and after the test using a pulse oximeter.
|
Baseline to 3 months
|
|
Functional capacity
大体时间:Baseline to 3 months
|
Participants' exercise capacity will be assessed using the Spiropalm 6MWT (Cosmed, Italy) six-minute walk test (6MWT) according to American Thoracic Society (ATS) criteria.
This device is a comprehensive system that includes an integrated pulse oximeter for monitoring oxygen saturation during the test and allows for measurement of heart rate, minute ventilation (VE), and respiratory pattern during walking.
The Spiropalm 6MWT meets all technical criteria set by the ATS for the 6MWT and is also compliant with ATD/ASD spirometry standards.
The test will be conducted in a 30-meter straight corridor in an enclosed area.
Participants will rest for at least 10 minutes before starting the test.
Following the rest period, heart rate, blood pressure, and oxygen saturation measurements will be taken.
In addition, dyspnea and leg fatigue levels will be assessed using the Modified Borg Scale (0-10).
Participants will be asked to walk at a pace faster than their normal walking
|
Baseline to 3 months
|
|
Ventilation (VE)
大体时间:Baseline to 3 months
|
During the 6MWT will be measured using a Spiropalm device.
|
Baseline to 3 months
|
|
Peak respiratory reserve (BRpeak)
大体时间:Baseline to 3 months
|
During the 6MWT, peak respiratory reserve (BRpeak) will be measured using a Spiropalm device.
|
Baseline to 3 months
|
|
Peak ventilation (VEpeak)
大体时间:Baseline to 3 months
|
During the 6MWT, peak ventilation (VEpeak) will be measured using a Spiropalm device.
|
Baseline to 3 months
|
|
Inspiratory capacity (IC)
大体时间:Baseline to 3 months
|
During the 6MWT, inspiratory capacity (IC) will be measured using a Spiropalm device.
|
Baseline to 3 months
|
|
Waist Index (WI) Adjusted for Weight
大体时间:Baseline to 3 months
|
This will be calculated according to the following formula based on waist circumference and weight measurements.
|
Baseline to 3 months
|
|
Skeletal Muscle Mass Index (SMMI)
大体时间:Baseline to 3 months
|
Skeletal Muscle Mass Index (SMMI) is calculated by dividing an individual's total skeletal muscle mass (kg) by the square of their height in meters (m²) (kg/m²).
|
Baseline to 3 months
|
|
Body Roundness Index (BRI)
大体时间:Baseline to 3 months
|
The Body Roundness Index (BRI) will be calculated using the individual's waist circumference (cm) and height (m) according to the standard formula defined in the literature.
The BRI value will be evaluated as an indicator of body fat distribution and abdominal obesity level.
|
Baseline to 3 months
|
|
Body muscle mass
大体时间:Baseline to 3 months
|
Participants' body muscle mass (kg) and body muscle percentage (%) will be measured using Bioelectrical Impedance Analysis (BIA).
Individuals will be informed about the test protocol and instructed to fast for 8-12 hours before the measurement, to arrive with an empty bladder, and to avoid fluids, food, and strenuous physical activity.
Measurements will be taken at a room temperature of 25°C, during the daytime, and participants will be asked to remove their shoes, socks, and all metal objects before stepping onto the device barefoot.
|
Baseline to 3 months
|
|
Body fat mass
大体时间:Baseline to 3 months
|
Participants' body fat mass (kg), body fat percentage (%) will be measured using Bioelectrical Impedance Analysis (BIA).
Individuals will be informed about the test protocol and instructed to fast for 8-12 hours before the measurement, to arrive with an empty bladder, and to avoid fluids, food, and strenuous physical activity.
Measurements will be taken at a room temperature of 25°C, during the daytime, and participants will be asked to remove their shoes, socks, and all metal objects before stepping onto the device barefoot.
|
Baseline to 3 months
|
|
Waist circumference
大体时间:Baseline to 3 months
|
Waist circumference will be measured with a non-stretch measuring tape.
The measurement will be taken three times at the level of the navel with the patient in an upright position during exhalation, with both feet bearing equal weight.
The average value will be recorded in centimeters (cm).
|
Baseline to 3 months
|
|
Daily step count
大体时间:Baseline to 3 months
|
Participants' physical activity levels will be assessed using a wearable activity monitor.
The device uses a six-axis sensor (accelerometer and gyroscope) to temporarily store data on the user's lifestyle and physical activity profile in its memory for the duration of wear.
The wearable activity monitor will track participants' daily step counts.
Participants will be asked to wear the activity monitor continuously on their left wrist for at least 72 hours, excluding sleep or bathing hours.
|
Baseline to 3 months
|
|
Fasting plasma glucose (FPG) and glycosylated hemoglobin (HbA1c)
大体时间:Baseline to 3 months
|
For the glucose profile of participants after 12 hours of fasting, fasting plasma glucose (FPG) and glycosylated hemoglobin (HbA1c) levels will be measured.
|
Baseline to 3 months
|
|
Lipid profile
大体时间:Baseline to 3 months
|
Participants will have their lipid profile measured after a 12-hour fast, including high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), total cholesterol, and triglyceride levels.
|