Sleep Evaluation Before and After Metabolic Surgery (SLEEP-BAM)
Sleep Evaluation in Patients Before and After Metabolic Surgery
Obesity is frequently associated with sleep disturbances, including poor sleep quality, insomnia symptoms, daytime sleepiness, and obstructive sleep apnea. Metabolic surgery is an effective treatment for obesity and may improve several sleep-related outcomes, but the long-term change in sleep quality after surgery is not well understood. Most previous studies have relied on questionnaires or single-night measurements, which may not fully reflect sleep patterns in daily life.
The SLEEP-BAM study is an observational longitudinal cohort study in adults scheduled for primary metabolic surgery at Catharina Hospital Eindhoven, the Netherlands. Participants will complete two home-based sleep measurement periods: one before surgery and one approximately 1 year after surgery. During each period, participants will wear two wearable devices for 5 consecutive nights: a Garmin Index Sleep Monitor and a viQtor research device. Participants will also complete sleep questionnaires and a daily sleep diary.
The main aim is to evaluate the change in objective sleep quality from before surgery to 1 year after surgery, measured using the Garmin Sleep Score. Secondary aims include evaluating changes in sleep duration, sleep efficiency, sleep timing, sleep regularity, oxygen saturation, heart rate variability, subjective sleep quality, daytime sleepiness, anxiety and depression symptoms, and quality of life. The study will also explore whether changes in sleep quality are associated with postoperative weight loss.
The study does not change the standard surgical treatment. Participants undergo metabolic surgery as part of routine care, and the research procedures consist only of sleep monitoring, questionnaires, and sleep diaries.
研究概览
详细说明
The SLEEP-BAM study is a single-center, within-subject longitudinal observational cohort study designed to evaluate sleep quality before and after primary metabolic surgery. The study will be conducted at Catharina Hospital Eindhoven, the Netherlands, a high-volume center for metabolic surgery.
Sleep disturbances are common in patients with obesity and may include poor sleep quality, insomnia symptoms, excessive daytime sleepiness, disrupted sleep timing, and obstructive sleep apnea. In routine metabolic surgery care, sleep evaluation is often focused mainly on obstructive sleep apnea screening, while other aspects of sleep are less frequently assessed. Metabolic surgery may improve sleep quality through weight loss, improvement of obesity-related comorbidities, and changes in metabolic health, but the longitudinal trajectory of sleep quality after surgery remains insufficiently understood.
Participants will be adults scheduled for primary metabolic surgery, including Roux-en-Y gastric bypass, sleeve gastrectomy, and, if performed within standard care, one-anastomosis gastric bypass. Revisional bariatric procedures are excluded. The study does not assign participants to a treatment or intervention. Surgery is performed as part of routine clinical care, independent of study participation.
Each participant will undergo two measurement periods. The first measurement period will take place before surgery, between 3 months and 2 weeks preoperatively. The second measurement period will take place approximately 1 year postoperatively. The 1-year postoperative measurement was chosen to align with the period in which substantial postoperative weight loss has usually occurred and with standard follow-up in the metabolic surgery care pathway.
During each measurement period, participants will wear two devices at home for 5 consecutive nights. The Garmin Index Sleep Monitor will be used to collect consumer-grade sleep outcomes, including the Garmin Sleep Score, total sleep time, sleep efficiency, sleep latency, nocturnal awakenings, sleep stages, and sleep timing parameters. The viQtor research device will be used to collect physiological signals, including photoplethysmography-based parameters such as oxygen saturation and heart rate variability, as well as raw photoplethysmography signals for exploratory analysis.
A valid night is defined as a night with at least 4 hours of usable recording during the participant's sleep period, based on the sleep diary and/or device-detected sleep period. At least 3 valid nights are required per measurement period. Evening wake-time recordings before sleep onset alone are not sufficient to define a valid night.
The primary outcome is the change in Garmin Sleep Score from preoperative baseline to 1 year after metabolic surgery. The Garmin Sleep Score is a device-derived composite score ranging from 0 to 100. It reflects several sleep-related aspects, including sleep duration, sleep stages, restlessness, and related metrics. The score is used as a pragmatic longitudinal measure of sleep quality in the home setting and is not considered equivalent to polysomnography or a diagnostic measure of sleep disorders.
Secondary outcomes include changes in objective sleep parameters, such as total sleep time, sleep efficiency, sleep latency, percentage of rapid eye movement sleep, nocturnal awakenings, peripheral oxygen saturation, heart rate variability, bedtime, wake time, mid-sleep time, sleep timing variability, and sleep regularity. Subjective sleep outcomes include the Pittsburgh Sleep Quality Index, Epworth Sleepiness Scale, Hospital Anxiety and Depression Scale, and sleep diary-derived parameters. Quality of life will be assessed using the OBESI-Q. Clinical outcomes include postoperative weight loss, expressed as percentage total weight loss.
The study will compare subjective sleep reports with objective wearable-derived sleep measures. It will also explore the association between changes in sleep quality and postoperative weight loss, while considering clinical variables such as age, sex, baseline body mass index, type of surgery, comorbidities, medication use, and quality of life. An exploratory analysis of raw photoplethysmography signals from the viQtor device will assess signal quality and examine whether derived research features correlate with Garmin sleep metrics. This exploratory analysis is intended as an early step toward potential development of sleep-related parameters and is not intended for diagnostic validation.
The planned sample size is 50 participants. The sample size was based on a paired within-subject comparison for the primary outcome, with an assumed moderate effect size. The target sample size includes an allowance for incomplete wearable recordings, insufficient valid nights, and loss to follow-up.
The study has received ethical approval from Medical Research Ethics Committees United under registration number R26.043. Participants will provide written informed consent before any study-specific procedures are performed. Participation is voluntary and withdrawal from the study will not affect standard medical care.
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Ephrahim E Jerry, MD
- 电话号码:+31634250807
- 邮箱:ephrahim.jerry@catharinaziekenhuis.nl
学习地点
-
-
North Brabant
-
Eindhoven、North Brabant、荷兰、5623EJ
- Catharina Ziekenhuis Eindhoven
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Age 18 years or older.
- Body mass index (BMI) of 40 kg/m² or higher, or BMI of 35 kg/m² or higher with obesity-related comorbidities.
- Scheduled for primary metabolic surgery, including Roux-en-Y gastric bypass, sleeve gastrectomy, or, if performed within standard care, one-anastomosis gastric bypass.
- Willing and able to wear wearable devices for 5 consecutive nights during both study measurement periods.
- Willing and able to complete sleep questionnaires and a daily sleep diary.
- No shift-based or irregular night-shift work schedule that could interfere with sleep measurements.
- Able and willing to provide written informed consent.
Exclusion Criteria:
- Revisional bariatric procedure.
- Diagnosed obstructive sleep apnea currently treated with continuous positive airway pressure (CPAP) or bilevel positive airway pressure (BiPAP).
- High clinical suspicion of obstructive sleep apnea during the standard preoperative work-up requiring further diagnostic evaluation or treatment.
- Chronic preoperative use of medications that may significantly alter sleep quality, including benzodiazepines, zolpidem, or other sedatives or sleep aids.
- Unable to complete the study procedures or comply with wearable device use, questionnaires, or sleep diary completion.
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Patients Undergoing Primary Metabolic Surgery
Adults with obesity scheduled for primary metabolic surgery at Catharina Hospital Eindhoven.
Participants will undergo metabolic surgery as part of routine clinical care and will complete home-based sleep monitoring before surgery and approximately 1 year after surgery.
|
Primary metabolic surgery performed as part of routine clinical care, including Roux-en-Y gastric bypass, sleeve gastrectomy, and, if performed within standard care, one-anastomosis gastric bypass.
Revisional bariatric procedures are excluded.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Change in Garmin Sleep Score
大体时间:Preoperative baseline and approximately 1 year postoperative
|
Change in objective sleep quality from preoperative baseline to approximately 1 year after metabolic surgery, measured using the Garmin Sleep Score.
The Garmin Sleep Score is a device-derived composite sleep quality score ranging from 0 to 100, with higher scores indicating better sleep quality.
It is based on sleep-related parameters including sleep duration, sleep stages, restlessness, and related metrics.
|
Preoperative baseline and approximately 1 year postoperative
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他相关的 MeSH 术语
其他研究编号
- NL-011757
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.