此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Intraoperative Ultrasound Assessment of Coronary Artery and Bypass Graft Blood Flow During CABG

Quantitative Assessment of Native Coronary Artery and Bypass Graft Blood Flow Using Intraoperative Ultrasound in Patients Undergoing Coronary Artery Bypass Grafting: A Single-Centre Prospective Feasibility and Safety Study

This single-centre, prospective observational feasibility and safety study will enrol 190 consecutive adults undergoing elective isolated coronary artery bypass grafting (CABG) at Nanjing Drum Tower Hospital. The study aims to evaluate the feasibility and safety of intraoperative ultrasound for the quantitative assessment of native coronary artery and bypass graft blood flow.

Transit-time flow measurement will be performed as part of routine intraoperative graft assessment. Additional ultrasound measurements will be obtained from major native coronary arteries before and after revascularisation and from bypass grafts after restoration of blood flow. The ultrasound findings will be collected for research purposes and will not influence graft revision or other intraoperative clinical decisions.

The co-primary outcomes are the participant-level technical success rate of the protocol-defined intraoperative ultrasound assessment and the incidence of adverse events related to the ultrasound device or measurement procedure. Secondary outcomes include agreement between ultrasound and transit-time flow measurements, changes in native coronary artery blood flow after revascularisation, measurement repeatability, and exploratory associations between intraoperative flow parameters and postoperative cardiac function and myocardial injury biomarkers. Participants will be followed for 30 ± 7 days after surgery.

研究概览

详细说明

Intraoperative assessment of bypass graft function is important for ensuring adequate myocardial revascularisation during coronary artery bypass grafting. Transit-time flow measurement is widely used for graft assessment but primarily evaluates blood flow within bypass grafts and provides limited information on changes in native coronary artery blood flow before and after revascularisation.

This study will evaluate a portable ultrasound platform with access to programmable raw radiofrequency data. The study-specific procedure consists of additional intraoperative ultrasound measurements obtained from the exposed epicardial surface without additional incision, vascular puncture or tissue penetration. Major native coronary arteries will be assessed before and after revascularisation, and individual bypass grafts will be assessed after completion of the graft anastomoses and restoration of blood flow. Transit-time flow measurements will be recorded according to routine clinical practice for subsequent agreement analyses.

The research ultrasound findings will not be used to guide graft revision, repeat anastomosis or other intraoperative clinical decisions. The study is designed to evaluate technical feasibility, safety, agreement with transit-time flow measurement, measurement repeatability and changes in native coronary artery blood flow. Associations between intraoperative flow parameters and postoperative cardiac function and myocardial injury biomarkers will be exploratory.

研究类型

观察性的

注册 (估计的)

190

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

    • Jiangsu
      • Nanjing、Jiangsu、中国、210008
        • Nanjing Drum Tower Hospital, Affiliated Hospital of Nanjing University Medical School
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

取样方法

非概率样本

研究人群

The study population will consist of adults undergoing elective isolated coronary artery bypass grafting in the Department of Cardiac Surgery at Nanjing Drum Tower Hospital. Consecutive patients meeting the eligibility criteria will be screened and enrolled after providing written informed consent.

描述

Inclusion Criteria:

  • Aged 18 years or older.
  • Confirmed coronary artery disease and scheduled to undergo elective isolated coronary artery bypass grafting at Nanjing Drum Tower Hospital.
  • Able and willing to provide written informed consent before any study-specific procedures are performed.

Exclusion Criteria:

  • Urgent, emergency, or salvage coronary artery bypass grafting.
  • Prolonged preoperative fasting, as defined in the study protocol, or inability to maintain adequate oral intake without enteral or parenteral nutritional support.
  • History of malignancy.
  • Body weight below 50 kg.
  • Preoperative hemodynamic instability requiring ongoing resuscitation or mechanical circulatory support, including intra-aortic balloon pump, extracorporeal membrane oxygenation, or left ventricular assist device support.
  • Endotracheal intubation and invasive mechanical ventilation before surgery.
  • Impaired consciousness, clinically significant central nervous system dysfunction, or evidence of cerebral malperfusion after hospital admission.
  • End-stage renal disease requiring maintenance dialysis before hospital admission.
  • Severe pulmonary disease considered to preclude tolerance of elective coronary artery bypass grafting or to confer an unacceptably high perioperative risk.
  • Severe peripheral vascular disease or clinical evidence of limb malperfusion before surgery.
  • History of gastrointestinal ulceration or chronic inflammatory gastrointestinal disease.
  • Chronic inflammatory or autoimmune disease, or long-term treatment with systemic corticosteroids or non-steroidal anti-inflammatory drugs.
  • Active infection or sepsis at screening.
  • Severe uncontrolled arrhythmia requiring urgent treatment or expected to cause marked intraoperative hemodynamic instability.
  • Previous cardiac surgery requiring repeat median sternotomy.
  • Planned concomitant major cardiac or aortic surgery, including valve surgery, congenital heart defect repair, or aortic surgery.
  • Inability to understand the study information or unwillingness or inability to provide written informed consent.
  • Inability or unwillingness to complete follow-up at 30 ± 7 days after surgery.
  • Pregnancy or breastfeeding.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Intraoperative Ultrasound CABG Cohort
This cohort will prospectively include adults undergoing elective isolated coronary artery bypass grafting. Ultrasound-derived blood flow parameters of native coronary arteries and bypass grafts will be collected at prespecified intraoperative time points. Transit-time flow measurements, perioperative data, postoperative cardiac function and myocardial injury biomarkers will also be collected. No parallel control cohort will be established, and the research ultrasound findings will not influence intraoperative clinical decision-making.
Intraoperative ultrasound measurements of major native coronary arteries will be obtained before and after revascularisation, followed by measurements of individual bypass grafts after restoration of blood flow. Recorded variables will include blood flow velocity, volumetric blood flow and other protocol-defined quantitative parameters. The findings will be collected for research purposes and will not guide graft revision or other intraoperative clinical decisions.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Participant-Level Technical Success Rate of the Protocol-Defined Intraoperative Ultrasound Assessment
大体时间:During the coronary artery bypass grafting procedure
The proportion of enrolled participants with analysable quantitative flow parameters obtained from ultrasound measurements of at least two major native coronary arteries both before and after revascularisation and from all protocol-specified independent bypass grafts. Failure to initiate or complete a protocol-defined measurement, visualise a required target vessel, obtain a stable flow signal, or generate analysable data will be classified as technical failure and retained in the denominator.
During the coronary artery bypass grafting procedure
Incidence of Adverse Events Related to the Intraoperative Ultrasound Device or Measurement Procedure
大体时间:From the first intraoperative ultrasound measurement to 30 ± 7 days after surgery
The proportion of participants with any adverse event judged by the investigator as possibly, probably, or definitely related to the intraoperative ultrasound device or measurement procedure. Prespecified events of special interest include a new or worsened sustained arrhythmia requiring treatment; clinically significant haemodynamic instability; bleeding or tissue injury attributable to probe contact or manipulation; native coronary artery, graft, or anastomotic injury; interruption or clinically meaningful prolongation of surgery attributable to ultrasound measurement; device malfunction posing a patient safety risk; and other related events as judged by the investigator.
From the first intraoperative ultrasound measurement to 30 ± 7 days after surgery

次要结果测量

结果测量
措施说明
大体时间
Agreement Between Intraoperative Ultrasound and Transit-Time Flow Measurements
大体时间:During CABG, after completion of graft anastomoses and restoration of blood flow
Agreement between comparable bypass graft blood flow parameters obtained using intraoperative ultrasound and transit-time flow measurement will be evaluated in grafts with analysable paired measurements using intraclass correlation coefficients and Bland-Altman analysis.
During CABG, after completion of graft anastomoses and restoration of blood flow
Mean Within-Vessel Change in Ultrasound-Derived Volumetric Blood Flow of Native Coronary Arteries Before and After Revascularisation
大体时间:During CABG: immediately before revascularisation and after completion of graft anastomoses following haemodynamic stabilisation
Volumetric blood flow will be measured in the same analysable segments of the left anterior descending, left circumflex, and right coronary arteries immediately before revascularisation and after completion of graft anastomoses following haemodynamic stabilisation. For each analysable native coronary artery, the within-vessel change will be calculated as post-revascularisation volumetric blood flow minus pre-revascularisation volumetric blood flow. The native coronary artery will be the unit of analysis, and the mean of all analysable vessel-level change values will be reported in mL/min. Positive values indicate increased blood flow after revascularisation.
During CABG: immediately before revascularisation and after completion of graft anastomoses following haemodynamic stabilisation
Repeatability of Intraoperative Ultrasound Blood Flow Measurements
大体时间:During the coronary artery bypass grafting procedure
Repeatability of intraoperative ultrasound-derived quantitative blood flow parameters will be evaluated using repeated measurements obtained at the same vascular measurement site. Intraclass correlation coefficients, coefficients of variation, repeatability coefficients, and Bland-Altman limits of agreement will be calculated.
During the coronary artery bypass grafting procedure
Association of Intraoperative Blood Flow Parameters With Postoperative Cardiac Function and Myocardial Injury Biomarkers
大体时间:From the preoperative baseline assessment to 30 ± 7 days after surgery
Associations between intraoperative ultrasound-derived native coronary artery and bypass graft blood flow parameters and postoperative measures of cardiac function, cardiac structure, and myocardial injury will be explored. Planned measures include left ventricular ejection fraction, left ventricular end-diastolic diameter, B-type natriuretic peptide or N-terminal pro-B-type natriuretic peptide, cardiac troponin T or cardiac troponin I, and other protocol-defined measures.
From the preoperative baseline assessment to 30 ± 7 days after surgery

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Qiang Wang, MD、Nanjing Drum Tower Hospital, Affiliated Hospital of Nanjing University Medical School

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2027年1月1日

初级完成 (估计的)

2028年12月31日

研究完成 (估计的)

2029年12月30日

研究注册日期

首次提交

2026年7月7日

首先提交符合 QC 标准的

2026年7月7日

首次发布 (实际的)

2026年7月14日

研究记录更新

最后更新发布 (实际的)

2026年8月11日

上次提交的符合 QC 标准的更新

2026年8月6日

最后验证

2026年7月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅