STRIDE: Strength of The Calf Muscles and Their Role In Declining Effectiveness of Movement With Aging (STRIDE)

2026年7月22日 更新者:University of Leicester
The calf muscles (plantarflexors) are the most important muscles for walking, running and daily activities. Weakness of these muscles through aging and disease significantly impact a person's ability to walk and complete daily activities. By assessing calf strength, it is possible to identify people at risk of falls, and a condition called sarcopenia (which means loss of muscle mass, strength and function). Unfortunately, most of the studies that have examined this have used specialist equipment unavailable to hospital staff. Our study aims to use commercially available equipment to explore the relationship between plantarflexor muscle strength and physical performance in adults living with or without sarcopenia, including those at risk of it. The study will determine if stronger/weaker calf muscles associated with sarcopenia influence the ability to walk and do things more easily. We will complete strength tests of the calf, thigh and hand, assess walking using a special camera system, use an ultrasound scan to look at the Achilles tendon, use a scan to look at how stiff your calf muscles are, assess your body composition, complete a physical performance test and some questionnaires. Each participant will complete the measures during one clinic visit

研究概览

详细说明

This study aims to assess the relationship between plantarflexor (calf muscles) muscle strength and physical performance between people with and without sarcopenia. The measurements include Isometric plantarflexor strength testing, Theia markerless motion capture system, Ultrasound Tissue Characterization Imaging, Elastography, Grip strength, Isometric Knee Extension Strength Test, Bioelectrical Impedance analysis, Short Physical Performance Battery. In addition the SARC-F, Falls Efficacy Scale- International (FES-I), EuroQol- 5 Dimension (EQ-5D-5L) and Short-Form-12-health-survey (SF-12) questionnaires will be completed.

研究类型

观察性的

注册 (估计的)

200

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Leicester、英国、LE1 7RH
        • University of Leicester
        • 接触:
        • 首席研究员:
          • Seth O'Neill, PhD
        • 副研究员:
          • Matt Harrison, BSc MA

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

是的

取样方法

非概率样本

研究人群

The study population is individuals over the age of 18 years, who may or may not have sarcopenia.

Individuals will be determined as either sarcopenic or non-sarcopenic by completing the outcome measures (SARC-F questionnaire, Grip strength, BIA and SPPB) and using the cut-off values as recommended by the European Working Group on Sarcopenia in Older People 2 consensus.

描述

Inclusion Criteria:

  • Participant is able and willing to provide informed consent to participate in the study
  • Aged 18 years or over
  • Ambulatory status: able to walk independently with or without aids
  • Able to attend clinic

Exclusion Criteria:

  • Participant is unwilling or unable to give informed consent.
  • Palliative/ end of life
  • Moderate to severe communication difficulties/ cognitive function
  • Immobile
  • Lower limb surgery within the last 6 months
  • Recent lower limb fracture
  • Unstable cardiopulmonary conditions
  • Severe impairments of vision or vestibular system
  • Lower limb corticosteroid injection within the last 6 months
  • No restriction on language

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Sarcopenic
无干预(观察性研究)
Non Sarcopenic
无干预(观察性研究)

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Isometric plantarflexor strength testing
大体时间:Baseline
Isometric plantarflexor strength will be tested using the Fysiometer C-station
Baseline

次要结果测量

结果测量
措施说明
大体时间
Theia markerless motion capture system
大体时间:Baseline
Gait will be assessed using Theia 3D (Theia Markerless Inc., Kingston, ON, Canada). Theia 3D is a commercial markerless motion capture system which uses multiple cameras to capture video footage of physical performance, tracking 124 keypoints producing 3D models. Calibration it completed prior to recording. Data is processed in Theia 3D and analysed in Visual 3D software. Measures such as gait speed and pattern, forces, joint angles, stride length and cadence will be collected.
Baseline
Ultrasound Tissue Characterization Imaging
大体时间:Baseline
Imaging of the Achilles Tendon to identify structural changes to the Achilles tendon.
Baseline
Elastography
大体时间:Baseline
Imaging of the Plantarflexors and Achilles Tendon to understand muscle stiffness and tissue mechanical properties
Baseline
Grip strength
大体时间:Baseline
A Jamar hand dynamometer will be used, measuring grip strength in kilograms
Baseline
Isometric Knee Extension Strength Test
大体时间:Baseline
Isometric Knee Extension strength will be measured using Kinvent K-Pull incline dynamometer
Baseline
Bioelectrical Impedance analysis
大体时间:Baseline
Bioelectrical impedance analysis (BIA) will be used to estimate body composition and Skeletal Muscle Mass.
Baseline
Short Physical Performance Battery
大体时间:Baseline
It consists of three key components: balance tests, gait speed and chair stand test. Participants who are unable to complete a component score 0, whereas a score of 4 indicates highest performance of that component. Each component is scored out of 4 points with a maximum combined score of 12 points.
Baseline
SARC-F questionnaire
大体时间:Baseline
The questionnaire contains 5 questions/components, covering strength, assistance with walking, rise from a chair, climb stairs and falls. Each component is scored ranging from 0 to 2 points, with a minimum combined score of 0 and a maximal combined score of 10. A score equal to or greater than 4 is predictive of sarcopenia and poor outcomes.
Baseline
Falls Efficacy Scale- International (FES-I)
大体时间:Baseline
The questionnaire contains sixteen questions/items. Each question/item is scored on a four-point Likert scale (1- not at all concerned; 2- somewhat concerned; 3- fairly concerned; 4- very concerned). The total score ranges from 16-64.
Baseline
EuroQol- 5 Dimension (EQ-5D-5L)
大体时间:Baseline
It consists of five dimensions (mobility, self-care, usual activities, pain/discomfort, anxiety/depression) and a visual analogue scale where individuals rate their overall health on a scale of 0-100.
Baseline
Short-Form-12-health-survey (SF-12)
大体时间:Baseline
It measures eight domains, covering physical functioning, role physical, bodily pain, general health perception, energy/vitality, social functioning, role emotional and mental health. Two summary scores are reported (Physical Component Summary and Mental Component Summary).
Baseline

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年8月1日

初级完成 (估计的)

2028年2月29日

研究完成 (估计的)

2028年2月29日

研究注册日期

首次提交

2026年7月17日

首先提交符合 QC 标准的

2026年7月22日

首次发布 (实际的)

2026年7月24日

研究记录更新

最后更新发布 (实际的)

2026年7月24日

上次提交的符合 QC 标准的更新

2026年7月22日

最后验证

2026年7月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅