Assessing the Feasibility of a Novel Dynamometry Protocol for Measuring Finger Extensor Strength
This study aims to evaluate the feasibility and reliability of a novel method for assessing finger extension strength using an adapted dynamometer, addressing the limitation of current hand grasp assessment protocols that focus only on finger flexor muscles. The study will recruit able-bodied adult participants, and a force gauge will be used to obtain precise measures of the strength of their extensor digitorum muscles.
Participants will be seated with their upper extremity supported on an adjustable table and have a force gauge, connected to a custom-made support positioned around their proximal phalanx. The support will be connected to a force gauge, which will measure participants' extensor muscles strength in Newtons (N). To assess the feasibility and reliability of this new setup, three measurements will be collected for each hand, with a one-minute interval between each measurement and a 5-minute break between evaluators, with the order randomized to reduce bias.
The study will recruit participants from BU's Sargent College of Health and Rehabilitation Sciences and will be conducted by independent evaluators trained in muscle assessment and clinical evaluation of the hand and upper extremities. The total participation time should not exceed 30 minutes per participant.
The primary hypothesis is that this novel and accessible device can provide accurate and reliable measurements of participants' finger extensor muscles' strength. Results from this study could have important implications for hand rehabilitation and therapy, particularly for individuals with hand dysfunction due to musculoskeletal disorders or injuries.
研究概览
地位
条件
详细说明
The purpose of this observational study is to measure the strength of independent finger extension for the four middle digits (II-V). Independent extension involves actively extending one finger while keeping the other fingers fully flexed, while dependent extension involves actively extending all the fingers, including the index finger. The study protocol is based on a previous study (Matter-Parrat et al., 2017), where researchers used a similar device to compare dependent and independent finger extension. However, in contrast to the previous study, this study aims to measure extension forces for all fingers, not just the index finger.
To achieve this, the tests will be performed three times, on both hands, by three examiners and compared to determine the intra-examiner reproducibility and the inter-examiner reproducibility. The investigators will measure all fingers on participants' dominant hand first, following by their non-dominant hand. This sequence will be repeated three times for each evaluator. A five-minute interval will be stablished between each evaluator, as well as 1-minute break between each attempt, to minimize the risk of muscle fatigue.
During the test procedures, the participants' upper extremity will be positioned over a height-adjustable table, which will be placed on the side of the participant. This will allow for optimal support and stability during the measurement of finger extension strength. The height of the table will be adjusted to ensure that the participant's shoulder is in abduction, and their elbows are at a 90-degree angle of flexion. The forearms will be placed in a pronated position, while the wrists and metacarpophalangeal joints will be maintained in a neutral position to prevent any unwanted movement during the test. The participants will be seated comfortably with their back supported by a chair with no armrests to avoid any interference with the test procedures. In case active extension of the wrist is observed by an elevation of the metacarpal heads from the stand, the test will be repeated to obtain isolated extension of the fingers.
To measure participants' finger extension strength, a 3D printed support was specifically designed and printed in PLA (Polylactic Acid) on an ENDER 3 printer. Additionally, PLA is a suitable material that can be easily disinfected with 70% ethanol, maintaining hygiene standards between participants. We will print several scaled models of the support, ensuring the support can be tailored to best fit participants' hands. We will select the support whose size comfortably accommodate the dorsum of the participant's proximal phalanx, providing a secure and ergonomic fit. Once the support is connected to the force gauge's M6 Metric attachments, participants will be asked to extend each finger independently as forcefully as possible while keeping the other fingers in full flexion.
Data will be obtained by recording the peak value using the Baoshishan 500N force gauge, a commercially available device used to measure the strength of extensor digitorum muscles. The device, manufactured by Baoshishan Instrument Co., Ltd, China, has a measuring range of 0-500N (0-112.4 lbf) and an accuracy of ±0.5% of full scale. It features a resolution of 0.1N (0.0225 lbf) and a sampling frequency of 2000Hz. The gauge has a large, easy-to-read LCD display that shows force values in Newtons (N) or pounds (lbf). The device is compact and lightweight, measuring 170 x 86 x 38 mm and weighing 0.5 kg. Safety precautions will be followed to ensure participant well-being, including proper handling of the device, avoiding damage to internal components, and keeping it away from water and other liquids. The rechargeable battery will be charged according to the manufacturer's instructions, and the device will be stored in a dry, cool place when not in use.
All data analysis procedures will be performed using SPSS version 27.0 (IBM Corp., Armonk, NY, USA). Continuous data will be presented as mean ± standard deviation, and categorical data will be presented as numbers and percentages. The normality of the distribution will be assessed using the Shapiro-Wilk test and graphically. For all statistical analyses, a significance level of 0.05 will be considered, and confidence intervals will be reported where appropriate.
To assess the reproducibility of the measurements, the intra-class correlation coefficient (ICC) will be calculated. The confidence interval for the ICC will be determined using the bootstrap method with 10,000 replicates. An F-test will be performed to determine if the ICC significantly differs from zero, indicating nil reproducibility. Good intra-examiner and inter-examiner reproducibility will be defined as ICC values above 0.90 and 0.75, respectively.
Mixed linear regression models will be used to compare extension strength between the dominant and non-dominant hands, incorporating a 'subject' random effect to account for within-subject correlation. This analysis will allow us to examine potential differences in finger extension strength between the hands while considering individual variation.
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
Massachusetts
-
Boston、Massachusetts、美国、02215
- Boston University - Department of Occupational Therapy
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
English-speaking adults No diagnosis or history of conditions affecting their upper extremities mobility.
Exclusion Criteria:
Current or past history of neurologic, rheumatologic, or orthopedic disorders impacting physical performance; A current disorder affecting cognition; Visual, tactile, or perceptual deficits that could prevent full participation in the study.
学习计划
研究是如何设计的?
设计细节
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Finger extensor - muscle force
大体时间:1 hour
|
Muscle force generated by participant's extensor digitorum muscles (both hands), measured in Newtons.
|
1 hour
|
合作者和调查者
调查人员
- 首席研究员:Pedro Almeida, PhD、Boston University - Department of Occupational Therapy
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 7053E
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.